Necessity of the Honan intraocular pressure reducer in cataract surgery using topical anesthesia

被引:1
|
作者
Black, EH [1 ]
Cohen, KL [1 ]
Tripoli, NK [1 ]
Winslow, PA [1 ]
机构
[1] Univ N Carolina, Dept Ophthalmol, Chapel Hill, NC 27599 USA
来源
关键词
D O I
10.1016/S0886-3350(99)80130-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the use of the Honan intraocular pressure reducer (HIPR) for clear corneal cataract surgery using topical anesthesia. Setting: University of North Carolina Hospitals Ambulatory Care Clinic outpatient operating rooms. Methods: Of 51 consecutive candidates for surgery (excluding those with uncontrolled glaucoma), 26 were randomly assigned to wear the HIPR (Honan group) for 10 minutes before surgery. The remainder were placed in a control group. Intraocular pressure (IOP) was measured before (T1) and after (T2) HIPR application and after patient preparation for surgery (T3). Results: Mean IOP was the same in the Honan and control groups at T1 and T3. At T2, the groups had a significantly different mean IOP (P = 1.8 x 10(-5)). In the Honan group, mean IOP decreased significantly (P = 2.8 X 10(-7)) between T1 and T2, and there was a significant correlation among patients at T1 and T2 (P < .0005). Between T2 and T3, the Honan group experienced a significant recovery (P = 3.5 x 10(-9)); there was a significant correlation between the decreases from T1 to T2 and the increases from T2 to T3 (P < .0005). Mean IOP in the control group did not change between T1 and T2 but increased significantly between T2 and T3 (P = .004). Conclusion: When using topical anesthesia, the HIPR transiently reduced IOP. However, the IOP-reducing effect resolved by the time of surgery, negating any reason to use the HIPR with topical anesthesia for cataract surgery.
引用
收藏
页码:223 / 226
页数:4
相关论文
共 50 条
  • [1] EFFECT OF APPLYING THE HONAN INTRAOCULAR-PRESSURE REDUCER BEFORE CATARACT-SURGERY
    JAY, WM
    CARTER, H
    WILLIAMS, B
    GREEN, K
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 100 (04) : 523 - 527
  • [2] Effect of the Honan intraocular pressure reducer in sub-Tenon's anesthesia
    Vallance, JH
    Patton, N
    Ferguson, A
    Bennett, HG
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02): : 433 - 436
  • [3] THE INTERRELATIONSHIP BETWEEN INTRAOCULAR-PRESSURE AND HONAN INTRAOCULAR-PRESSURE REDUCER PRESSURE
    GREEN, K
    HARMAN, D
    CHEEKS, L
    CURRENT EYE RESEARCH, 1986, 5 (08) : 621 - 623
  • [4] PREOPERATIVE USE OF THE HONAN INTRAOCULAR-PRESSURE REDUCER
    QUIST, LH
    STAPLETON, SS
    MCPHERSON, SD
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1983, 95 (04) : 536 - 538
  • [5] Anesthesia for intraocular surgery II. Topical/intracameral anesthesia for cataract surgery
    Hasan, SA
    Edelhauser, HF
    Kim, T
    SURVEY OF OPHTHALMOLOGY, 2001, 46 (02) : 178 - 181
  • [6] THE HONAN INTRAOCULAR-PRESSURE REDUCER - AN EXPERIMENTAL-STUDY
    MCDONNELL, PJ
    QUIGLEY, HA
    MAUMENEE, AE
    STARK, WJ
    HUTCHINS, GM
    ARCHIVES OF OPHTHALMOLOGY, 1985, 103 (03) : 422 - 425
  • [7] Effect of the Honan intraocular pressure reducer on intraocular pressure increase following intravitreal injection using the tunneled scleral technique
    Kyu-seop Kim
    Donghyun Jee
    Japanese Journal of Ophthalmology, 2011, 55 : 632 - 637
  • [8] Effect of the Honan intraocular pressure reducer on intraocular pressure increase following intravitreal injection using the tunneled scleral technique
    Kim, Kyu-seop
    Jee, Donghyun
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (06) : 632 - 637
  • [9] The Effect of Melatonin on Analgesia, Anxiety, and Intraocular Pressure (IOP) in Cataract Surgery Under Topical Anesthesia
    Sane, Shahryar
    Motarjemizadeh, Qader
    Komilzhonovich, Ibragimov Nematjon
    Abdelbasset, Walid Kamal
    Zaman, Gaffar Sarwar
    Suksatan, Wanich
    Morwati, Shabnam
    Haki, Behzad Kazemi
    Rahmani, Nazila
    Golabi, Parang
    Mahmodi, Hamed
    JOURNAL OF PERIANESTHESIA NURSING, 2023, 38 (02) : 253 - 257
  • [10] USE OF THE HONAN INTRAOCULAR-PRESSURE REDUCER AT THE WILMER-INSTITUTE
    MARTIN, NF
    STARK, WJ
    MAUMENEE, AE
    BRUNER, WE
    ROSENBLUM, P
    OPHTHALMIC SURGERY AND LASERS, 1982, 13 (02): : 101 - 103