Scintigraphic validation of a magnetic resonance imaging method to study gastric emptying of a solid meal in humans

被引:113
|
作者
Feinle, C
Kunz, P
Boesiger, P
Fried, M
Schwizer, W
机构
[1] Univ Zurich Hosp, Dept Internal Med, Div Gastroenterol, CH-8091 Zurich, Switzerland
[2] Univ Zurich, ETH, Inst Biomed Engn & Med Informat, Zurich, Switzerland
关键词
magnetic resonance imaging; scintigraphy; gastric emptying; solid meal; liquid meal;
D O I
10.1136/gut.44.1.106
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background-We have previously used a magnetic resonance imaging (MRI) method to study gastric emptying of liquids. So far, however, it has not possible to assess solid gastric emptying with this technique. Aims-To validate scintigraphically MRI as a method for measuring emptying of a mixed solid/liquid meal. Methods-In eight healthy subjects, gastric emptying of a solid/liquid (SM) and a liquid meal (LM) of identical energy content and macronutrient composition was studied by scintigraphy and MRI for 120 minutes. Results-MRI and scintigraphy agreed with respect to emptying profiles (intraclass correlation coefficient (R-I)(SM): 0.988, (r), (LM): 0.917), t(1/2) (SMMRI: 129 (9), SMScinti: 123 (11) minutes, NS; L-MRI: 100 (7), LMScinti: 110 (8) minutes, NS) and AUC (SMMRI: 8999 (232), SMScinti: 8788 (277) min%, NS; LMMRI: 8819 (368), LMScinti: 8891 (321) min%, NS). Conclusions-MRI can be used to measure reliably gastric emptying not only of liquid but also of mixed solid/liquid meals in humans.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 50 条
  • [1] Validation of an MRI method to study gastric emptying of a solid meal in humans.
    Feinle, C
    Kunz, P
    Hebbard, G
    Boesiger, P
    Fried, M
    Schwizer, W
    GASTROENTEROLOGY, 1997, 112 (04) : A730 - A730
  • [2] SCINTIGRAPHIC STUDY OF GASTRIC-EMPTYING OF A SOLID MEAL IN THE DIABETIC
    FILALI, A
    CHABCHOUB, H
    CHAMAKHI, S
    KRAIEM, A
    BENAMMAR, A
    MTIMET, S
    GAROUI, H
    BOUKHRIS, R
    JOURNAL DE BIOPHYSIQUE ET DE BIOMECANIQUE, 1985, 9 (03): : 228 - 228
  • [3] Measurement of gastric accommodation and emptying of a solid meal by magnetic resonance imaging.
    Choi, MG
    Kim, BW
    Choo, KY
    Park, SH
    Jung, SE
    Lee, JM
    Han, SW
    Chung, IS
    Chung, KW
    Sun, HS
    GASTROENTEROLOGY, 2000, 118 (04) : A388 - A389
  • [4] The evaluation of magnetic resonance imaging (MRI) to assess gastric emptying of liquid and solid meal
    Kiyota, K
    Inokuchi, H
    Habu, Y
    Hirota, M
    Tahashi, Y
    Matsumura, M
    GASTROENTEROLOGY, 1996, 110 (04) : A696 - A696
  • [5] The effect of macronutrients on gastric volume responses and gastric emptying in humans: a magnetic resonance imaging study
    Goetze, Oliver
    Steingoetter, Andreas
    Menne, Dieter
    van der Voort, Ivo R.
    Kwiatek, Monika A.
    Boesiger, Peter
    Weishaupt, Dominik
    Thumshirn, Miriam
    Fried, Michael
    Schwizer, Werner
    AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 2007, 292 (01): : G11 - G17
  • [6] MEASUREMENT OF GASTRIC-EMPTYING BY MAGNETIC-RESONANCE-IMAGING IN HUMANS
    SCHWIZER, W
    MAECKE, H
    FRIED, M
    GASTROENTEROLOGY, 1992, 103 (02) : 369 - 376
  • [7] GASTRIC-EMPTYING OF RADIONUCLIDE-LABELED SOLID MEAL IN BEAGLE DOGS USING A SCINTIGRAPHIC METHOD
    TERRANI, S
    PACENTI, P
    SCHIAVONE, A
    METHODS AND FINDINGS IN EXPERIMENTAL AND CLINICAL PHARMACOLOGY, 1993, 15 (07): : 459 - 463
  • [8] Solid-Meal Gastric Emptying Study
    Thomas, Kathy S.
    Farrell, Mary Beth
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2019, 47 (02) : 127 - 128
  • [9] The effects of posture on gastric emptying:: A magnetic resonance imaging study
    Fox, M
    Steingötter, A
    Boesinger, P
    Fried, M
    Schwizer, W
    GUT, 2005, 54 : A22 - A22
  • [10] Simultaneous assessment of gastric accommodation and emptying of a solid meal: A new scintigraphic test.
    Maurer, AH
    Simonian, HP
    Kantor, S
    Knight, LC
    Megalooikonomou, V
    Fisher, RS
    Parkman, HP
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 93P - 93P