A new method for three-dimensional immunofluorescence study of the cochlea

被引:13
|
作者
Brody, Kate M. [1 ]
Hampson, Amy J. [1 ]
Cho, Hyun-jung [2 ]
Johnson, Prudence [1 ]
O'Leary, Stephen J. [1 ]
机构
[1] Univ Melbourne, Royal Victorian Eye & Ear Hosp, Dept Surg, Otolaryngol, East Melbourne, Australia
[2] Univ Melbourne, Biol Opt Microscopy Platform, Parkville, Vic, Australia
基金
英国医学研究理事会;
关键词
Whole cochlea imaging; Immunofluorescence; Tissue clearing; Cochlear implant; Light sheet microscopy; SHEET FLUORESCENCE MICROSCOPY; GUINEA-PIG; HEARING-LOSS; RESIDUAL HEARING; IMPLANTATION; HISTOPATHOLOGY; NEUROTROPHINS; PROTECTION; PREVENTS; DELIVERY;
D O I
10.1016/j.heares.2020.107956
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Visualisation of cochlear histopathology in three-dimensions has been long desired in the field of hearing research. This paper outlines a technique that has made this possible and shows a research application in the field of hearing protection after cochlear implantation. The technique utilises robust immunofluorescent labelling followed by effective tissue clearing and fast image acquisition using Light Sheet Microscopy. We can access the health of individual components by immunofluorescent detection of proteins such as myosin VIIa to look at cochlear hair cells, NaKATPase alpha 3 to look at spiral ganglion neurons, and IBA1 to look at macrophages within a single cochlea, whilst maintaining the integrity of fine membranous structures and keeping the cochlear implant in place. This allows the tissue response to cochlear implantation to be studied in detail, including the immune reaction to the implant and the impact on the structure and health of neural components such as hair cells. This technique reduces time and labour required for sectioning of cochleae and can allow visualisation of cellular detail. Use of image analysis software allows conversion of high-resolution image stacks into three-dimensional interactive data sets so volumes and numbers of surfaces can be measured. Immunofluorescent whole cochlea labelling and Light Sheet Microscopy have the capacity to be applied to many questions in hearing research of both the cochlea and vestibular system. (C) 2020 The Authors. Published by Elsevier B.V.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A method for forward and inverse solutions of a three-dimensional model of the cochlea
    de Boer, E
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 103 (06): : 3725 - 3728
  • [2] Three-dimensional modelling and visualisation of the cochlea
    Zakis, JD
    Pudlowski, ZJ
    4TH BALTIC REGION SEMINAR ON ENGINEERING EDUCATION, SEMINAR PROCEEDINGS, 2000, : 101 - 105
  • [3] Three-dimensional geometric modeling of the cochlea
    Yoo, SK
    Wang, G
    Rubinstein, JT
    Vannier, MW
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 1573 - 1580
  • [4] A comprehensive three-dimensional model of the cochlea
    Givelberg, E
    Bunn, J
    JOURNAL OF COMPUTATIONAL PHYSICS, 2003, 191 (02) : 377 - 391
  • [5] Three-dimensional modeling and visualization of the cochlea on the Internet
    Yoo, SK
    Wang, G
    Rubinstein, JT
    Skinner, MW
    Vannier, MW
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2000, 4 (02): : 144 - 151
  • [6] Three-dimensional image analysis of the mouse cochlea
    Wright, Graham D.
    Horn, Henning F.
    DIFFERENTIATION, 2016, 91 (4-5) : 104 - 108
  • [7] Bone conduction in a three-dimensional model of the cochlea
    Boehnke, Frank
    Arnold, Wolfgang
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2006, 68 (06): : 393 - 396
  • [8] Study on a new three-dimensional troposcatter parabolic equation method
    Liang, Shuaishuai
    Li, Lei
    Lin, Leke
    Zhao, Zhenwei
    IET MICROWAVES ANTENNAS & PROPAGATION, 2025, 19 (01)
  • [9] Three-dimensional reconstruction of tectorial membrane motion in the cochlea
    Dong, W
    Cooper, NP
    BRITISH JOURNAL OF AUDIOLOGY, 2000, 34 (02): : 88 - 88
  • [10] Study of a new method for three-dimensional restoration from single image
    XIE MinghongCollege of Mechanical Engineering and AutomationHuaqiao UniversityQuanzhou PRChina
    重庆邮电大学学报(自然科学版), 2009, (02) : 200 - 206