No-gold-standard evaluation of partial volume compensation methods for brain PET

被引:0
|
作者
Zhu, Yansong [1 ,2 ]
Liu, Ziping [3 ]
Bilgel, Murat [4 ]
Rahmim, Arman [2 ]
Jha, Abhinav [3 ]
机构
[1] Johns Hopkins Univ, Baltimore, MD USA
[2] Univ British Columbia, Vancouver, BC, Canada
[3] Washington Univ, St Louis, MO 63110 USA
[4] NIA, Baltimore, MD 21224 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
1409
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Comparing clinical evaluation of PET segmentation methods with reference-based metrics and no-gold-standard evaluation technique
    Zhu, Yansong
    Yousefirizi, Fereshteh
    Liu, Ziping
    Klyuzhin, Ivan
    Rahmim, Arman
    Jha, Abhinav
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [2] No-gold-standard evaluation of quantitative imaging methods in the presence of correlated noise
    Liu, Ziping
    Li, Zekun
    Mhlanga, Joyce C.
    Siegel, Barry A.
    Jha, Abhinav K.
    MEDICAL IMAGING 2022: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2022, 12035
  • [3] No-gold-standard evaluation of image-acquisition methods using patient data
    Jha, Abhinav K.
    Frey, Eric
    MEDICAL IMAGING 2017: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2017, 10136
  • [4] No-gold-standard evaluation of quantitative SPECT methods for alpha-particle radiopharmaceutical therapy
    Liu, Yan
    Liu, Ziping
    Li, Zekun
    Thorek, Daniel
    Siegel, Barry
    Jha, Abhinav
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [5] Objective evaluation of voxelwise partial volume correction methods in brain PET imaging
    Bilgel, Murat
    Zhu, Yansong
    Rousset, Olivier
    Wong, Dean
    Resnick, Susan
    Rahmim, Arman
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [6] A no-gold-standard technique for objective evaluation of quantitative nuclear-medicine imaging methods in the presence of correlated noise
    Liu, Jinxin
    Liu, Ziping
    Moon, Hae Sol
    Mhlanga, Joyce
    Jha, Abhinav
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [7] Brain PET partial-volume compensation using blurred anatomical labels
    Bataille, F.
    Comtat, C.
    Jan, S.
    Sureau, F. C.
    Trebossen, R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1606 - 1615
  • [8] Brain PET Partial-Volume Compensation Using Blurred Anatomical Labels
    Bataille, F.
    Comtat, C.
    Jan, S.
    Sureau, F. C.
    Trebossen, R.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1817 - 1824
  • [9] A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods
    Jha, Abhinav K.
    Caffo, Brian
    Frey, Eric C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07): : 2780 - 2801
  • [10] Investigation of partial volume correction methods for brain FDG PET studies
    Yang, J
    Huang, SC
    Mega, M
    Lin, KP
    Toga, AW
    Small, GW
    Phelps, ME
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3322 - 3327