Full-field hard X-ray microscopy based on aberration-corrected Be CRLs

被引:2
|
作者
Schropp, Andreas [1 ]
Brueckner, Dennis [1 ,2 ]
Bulda, Jessica [1 ]
Falkenberg, Gerald [1 ]
Garrevoet, Jan [1 ]
Hagemann, Johannes [1 ]
Seiboth, Frank [1 ]
Spiers, Kathryn [1 ]
Koch, Frieder [3 ]
David, Christian [3 ]
Gambino, Marianna [4 ]
Vesely, Martin [4 ]
Meirer, Florian [4 ]
Schroer, Christian G. [1 ,3 ,5 ]
机构
[1] Deutsch Elektronen Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany
[2] Ruhr Univ Bochum, Univ Str 150, D-44780 Bochum, Germany
[3] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[4] Univ Utrecht, Univ Weg 99, NL-3584 CG Utrecht, Netherlands
[5] Univ Hamburg, Luruper Chaussee 149, D-22761 Hamburg, Germany
关键词
hard X-ray microscopy; full-field imaging; tomography; refractive X-ray optics; compound refractive lenses; corrective phase plates; REFRACTIVE LENSES; TOMOGRAPHY;
D O I
10.1117/12.2528422
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To date, compound refractive X-ray lenses made out of Beryllium (Be CRLs) have been seldom applied for full-field microscopy with high spatial resolution, which was probably due to residual aberrations of these optics. However, in combination with the recent development of made-to-measure phase plates, the typical spherical aberration of beryllium compound refractive lenses (Be CRLs) can now be completely removed. In this way, distortion-free images of a sample are obtained, which is especially important for tomographic applications. First full-field imaging experiments with aberration-corrected Be CRLs were carried out at beamline P06 at the synchrotron radiation X-ray source PETRA III (DESY Hamburg, Germany). In order to maximize the magnification of the X-ray microscope for full-field microscopy, the full length of the beamline combining the micro- and nanohutch was utilized, enabling a large sample-to-detector distance. In this contribution, we present first imaging results, demonstrating the potential of Be CRLs for direct high-resolution X-ray tomography.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Fractal-based aberration-corrected full-field OCT
    Zhu, Yue
    Zhou, Yuan
    Guo, Zhenyan
    [J]. BIOMEDICAL OPTICS EXPRESS, 2023, 14 (07) : 3775 - 3797
  • [2] Applications of Hard X-ray Full-Field Transmission X-ray Microscopy at SSRL
    Liu, Y.
    Andrews, J. C.
    Meirer, F.
    Mehta, A.
    Carrasco Gil, S.
    Sciau, P.
    Mester, Z.
    Pianetta, P.
    [J]. 10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 357 - 360
  • [3] Full-field hard x-ray microscopy with interdigitated silicon lenses
    Simons, Hugh
    Stohr, Frederik
    Michael-Lindhard, Jonas
    Jensen, Flemming
    Hansen, Ole
    Detlefs, Carsten
    Poulsen, Henning Friis
    [J]. OPTICS COMMUNICATIONS, 2016, 359 : 460 - 464
  • [4] Dual scanning and full-field hard x-ray microscopy with a laboratory source
    Blackhall, Cristoffer J.
    Morgan, Kaye S.
    Pelliccia, Daniele
    [J]. OPTICS EXPRESS, 2014, 22 (13): : 15437 - 15446
  • [5] Full-field transmission x-ray microscopy at SSRL
    Andrews, J. C.
    Brennan, S.
    Pianetta, P.
    Ishii, H.
    Gelb, J.
    Feser, M.
    Rudati, J.
    Tkachuk, A.
    Yun, W.
    [J]. 9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [6] Laboratory Full-Field Transmission X-ray Microscopy
    Seim, Christian
    Baumann, Jonas
    Legalla, Herbert
    Redlich, Christoph
    Mantouvalou, Ioanna
    Blobel, G.
    Stiel, Holger
    Kanngiesser, Birgit
    [J]. SHORT-WAVELENGTH IMAGING AND SPECTROSCOPY SOURCES, 2012, 8678
  • [7] Full-field hard x-ray microscopy below 30 nm: a challenging nanofabrication achievement
    Chen, Yu-Tung
    Lo, Tsung-Nan
    Chu, Yong S.
    Yi, Jaemock
    Liu, Chi-Jen
    Wang, Jun-Yue
    Wang, Cheng-Liang
    Chiu, Chen-Wei
    Hua, Tzu-En
    Hwu, Yeukuang
    Shen, Qun
    Yin, Gung-Chian
    Liang, Keng S.
    Lin, Hong-Ming
    Je, Jung Ho
    Margaritondo, Giorgio
    [J]. NANOTECHNOLOGY, 2008, 19 (39)
  • [8] Magnetic imaging with full-field soft X-ray microscopy
    Fischer, P.
    Eimüller, T.
    Goll, D.
    Stoll, H.
    Puzic, A.
    Schütz, G.
    Denbeaux, G.
    [J]. International Journal of Materials Research, 2002, 93 (05) : 377 - 382
  • [9] Magnetic imaging with full-field soft X-ray microscopy
    Fischer, P
    Eimüller, T
    Goll, D
    Stoll, H
    Puzic, A
    Schütz, G
    Denbeaux, G
    [J]. ZEITSCHRIFT FUR METALLKUNDE, 2002, 93 (05): : 377 - 382
  • [10] Laboratory Source Based Full-Field X-Ray Microscopy at 9 keV
    Fella, C.
    Balles, A.
    Wiest, W.
    Zabler, S.
    Hanke, R.
    [J]. XRM 2014: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2016, 1696