Comparison of methods for adaptive removal of motion artifact

被引:69
|
作者
Hamilton, PS [1 ]
Curley, MG [1 ]
Aimi, RM [1 ]
Sae-Hau, C [1 ]
机构
[1] EP Ltd, Sommerville, MA 02143 USA
来源
COMPUTERS IN CARDIOLOGY 2000, VOL 27 | 2000年 / 27卷
关键词
D O I
10.1109/CIC.2000.898537
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Motion artifact is a significant source of noise in ambulator, ECG monitoring and can occur frequently during Holter recording and stress testing. We have investigated methods for removing motion artifact from ECG signals using adaptive noise removal. We have investigated both the use of an electrode/skin impedance signal and a signal from a physical sensor (Measurand Shape Sensor (TM)) mounted on the electrode for adaptively modeling and removing motion artifact. The skin/electrode signal and physical sensor signals can both be used to produce equivalent noise reduction but in addition to requiring the sensors, higher order adaptive filters (5(th) order vs. 3(rd) order) were required when the physical sensor signal was used. Guided by the results of these tests, we have designed and implemented a portable ECG recorder using 120 Hz impedance based motion artifact removal to investigate the utility of motion artifact removal for Holter and stress recording.
引用
收藏
页码:383 / 386
页数:4
相关论文
共 50 条
  • [1] Adaptive removal of motion artifact
    Hamilton, PS
    Curley, MG
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 297 - 299
  • [2] Motion Artifact Removal for Functional Near Infrared Spectroscopy: A Comparison of Methods
    Robertson, F. C.
    Douglas, T. S.
    Meintjes, E. M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (06) : 1377 - 1387
  • [3] OCULAR ARTIFACT REMOVAL FROM EEG: A COMPARISON OF SUBSPACE PROJECTION AND ADAPTIVE FILTERING METHODS
    Kroupi, Eleni
    Yazdani, Ashkan
    Vesin, Jean-Marc
    Ebrahimi, Touradj
    19TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO-2011), 2011, : 1395 - 1399
  • [4] Comparison of Reference Sensor Types and Position for Motion Artifact Removal in ECG
    Lilienthal, Jannis
    Dargie, Waltenegus
    29TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO 2021), 2021, : 1296 - 1300
  • [5] Motion Artifact Removal from Capacitive ECG Measurements by Means of Adaptive Filtering
    Eilebrecht, B.
    Wartzek, T.
    Willkomm, J.
    Schommartz, A.
    Walter, M.
    Leonhardt, S.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 902 - +
  • [6] Combining Nonlinear Adaptive Filtering and Signal Decomposition for Motion Artifact Removal in Wearable Photoplethysmography
    Ye, Yalan
    Cheng, Yunfei
    He, Wenwen
    Hou, Mengshu
    Zhang, Zhilin
    IEEE SENSORS JOURNAL, 2016, 16 (19) : 7133 - 7141
  • [7] Use of power-line interference for adaptive motion artifact removal in biopotential measurements
    Xu, Lin
    Rooijakkers, Michael J.
    Rabotti, Chiara
    Peuscher, Jan
    Mischi, Massimo
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (01) : 25 - 40
  • [8] Motion Artifact Removal using Cascade Adaptive Filtering for Ambulatory ECG Monitoring System
    Kim, Hyejung
    Kim, Sunyoung
    Van Helleputte, Nick
    Berset, Torfinn
    Geng, Di
    Romero, Inaki
    Penders, Julien
    Van Hoof, Chris
    Yazicioglu, Refet Firat
    2012 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): INTELLIGENT BIOMEDICAL ELECTRONICS AND SYSTEM FOR BETTER LIFE AND BETTER ENVIRONMENT, 2012, : 160 - 163
  • [9] Adaptive reduction of motion artifact in the electrocardiogram
    Tong, DA
    Bartels, KA
    Honeyager, KS
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1403 - 1404
  • [10] Adaptive motion artifact suppression in CT
    Hsieh, J
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XIX, 1996, 2847 : 429 - 437