Electrochemical oxidation of hyperforin on glassy carbon electrode and determination in herbal medicinal products

被引:2
|
作者
Michelitsch, A [1 ]
Wurglics, M
机构
[1] Karl Franzens Univ Graz, Inst Pharmaceut Chem & Pharmaceut Technol, Graz, Austria
[2] Univ Frankfurt, Inst Pharmaceut Chem, D-6000 Frankfurt, Germany
关键词
hyperforin; differential pulse voltammetry; cyclic voltammetry; glassy carbon electrode; herbal medicinal products;
D O I
10.1002/elan.200390098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hyperfolin, one of the active components of St. John's Wort and St. John's Wort extracts is oxidized on the glassy carbon electrode. Electrode process, type and reversibility were examined by means of cyclic voltammetry in various buffer systems (NaAc/HAc, Sorensen-phosphate buffer, borate buffer). A differential pulse voltammetric method was developed for the determination of hyperforin. In the concentration range from 1.0 wg/mL to 40.0 mug/mL there is a strong linearity between the concentration of hyperforin and peak height. The detection limit is 200 ng/mL. The differential pulse voltammetric method developed is used to determine hyperforin in herbal medicinal products.
引用
下载
收藏
页码:797 / 802
页数:6
相关论文
共 50 条
  • [1] Electrochemical Oxidation of Berberine and of Its Oxidation Products at a Glassy Carbon Electrode
    Diculescu, Victor C.
    Enache, Teodor Adrian
    Oliveira, Paulo J.
    Oliveira-Brett, Ana Maria
    ELECTROANALYSIS, 2009, 21 (09) : 1027 - 1034
  • [2] Electrochemical behavior and determination of clozapine on a glassy carbon electrode modified by electrochemical oxidation
    Farhadi, Khalil
    Karimpour, Ahmad
    ANALYTICAL SCIENCES, 2007, 23 (04) : 479 - 483
  • [3] Electrochemical Behavior and Determination of Clozapine on a Glassy Carbon Electrode Modified by Electrochemical Oxidation
    Khalil Farhadc
    Ahmad Karimpour
    Analytical Sciences, 2007, 23 : 479 - 483
  • [4] Electrochemical determination of mesotrione and its degradation products on glassy carbon electrode
    Barchanska, Hanna
    Markowski, Piotr
    Strzebin, Magdalena
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (06) : 493 - 505
  • [5] Electrochemical oxidation of niclosamide at a glassy carbon electrode and its determination by voltammetry
    Alemu, H
    Khoabane, NM
    Tseki, PF
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2003, 17 (01) : 95 - 106
  • [6] Electrochemical Oxidation of Sulfasalazine at a Glassy Carbon Electrode
    Buoro, Rafael M.
    Diculescu, Victor C.
    Lopes, Ilanna C.
    Serrano, Silvia H. P.
    Oliveira-Brett, Ana Maria
    ELECTROANALYSIS, 2014, 26 (05) : 924 - 930
  • [7] Electrochemical oxidation of benzene at a glassy carbon electrode
    K.-W. Kim
    M. Kuppuswamy
    R.F. Savinell
    Journal of Applied Electrochemistry, 2000, 30 : 543 - 549
  • [8] Electrochemical Oxidation of Metolazone at a Glassy Carbon Electrode
    Pontinha, A. Dora R.
    Oliveira, S. Carlos B.
    Oliveira-Brett, Ana Maria
    ELECTROANALYSIS, 2008, 20 (23) : 2531 - 2536
  • [9] Electrochemical oxidation of mitoxantrone at a glassy carbon electrode
    Brett, AMO
    Macedo, TRA
    Raimundo, D
    Marques, MH
    Serrano, SHP
    ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) : 401 - 408
  • [10] Electrochemical oxidation of benzene at a glassy carbon electrode
    Kim, KW
    Kuppuswamy, M
    Savinell, RF
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2000, 30 (05) : 543 - 549