Tailoring selective laser melting process for titanium drug-delivering implants with releasing micro-channels

被引:56
|
作者
Hassanin, Hany [1 ,2 ]
Finet, Laurane [2 ]
Cox, Sophie C. [3 ]
Jamshidi, Parastoo [2 ]
Grover, Liam M. [3 ]
Shepherd, Duncan E. T. [4 ]
Addison, Owen [5 ]
Attallah, Moataz M. [2 ]
机构
[1] Kingston Univ, Sch Mech & Aerosp Engn, London SW15 3DW, England
[2] Univ Birmingham, Sch Met & Mat, Edgbaston B15 2TT, England
[3] Univ Birmingham, Sch Chem Engn, Edgbaston B15 2TT, England
[4] Univ Birmingham, Sch Engn, Dept Mech Engn, Edgbaston B15 2TT, England
[5] Univ Birmingham, Sch Dent, Edgbaston B15 2TT, England
基金
英国工程与自然科学研究理事会;
关键词
Selective laser melting; Titanium alloys; Medical implants; Surface roughness; 316L STAINLESS-STEEL; MECHANICAL-PROPERTIES; BIOMEDICAL APPLICATIONS; ORTHOPEDIC IMPLANTS; POROSITY; MICROSTRUCTURE; ALLOYS; PARTS; FLOW;
D O I
10.1016/j.addma.2018.01.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The use of drug-delivering implants can minimise implant failure due to infection through a controlled medication release into the surrounding tissues. In this study, selective laser melting (SLM) was employed to manufacture Ti-6Al-4 V samples, with internal reservoirs and releasing Micro-channels (MCs) to simulate what could be a drug-delivering orthopaedic or dental implant. Investigations were performed to optimise the design and SLM process parameters required to create the releasing MCs with minimum dimensional deviation to allow a controlled dosing of the drugs, while considering the process impact on the surface roughness and porosity of the builds. The build orientation, internal contour spacing, and laser process parameters were varied to assess their effect on the resolution of the MCs with diameters of similar to 200-500 mu m. It was found that, vertically oriented channels were found to have the least dimensional deviation from the target dimensions compared with horizontally-oriented or inclined channels. The dimensional deviation of the MCs was found in range of 220-427 mu m, while the horizontal surface roughness (R-a) was in range of 1.46-11.46 mu m and the vertical surface roughness (R-a) was in range of 8.5-13.23 mu m when applying energy density varying from of 27-200 J/mm(3). It was found that, there was a clear correlation between the energy density with both dimensional deviation and horizontal surface roughness, while no correlation was found for the vertical' surface roughness. The study identified the optimum conditions to manufacture drug-delivering metallic implants, creating hollow samples with releasing MCs equivalent diameter of similar to 271 mu m, horizontal surface roughness (R-a) of 4.4 mu m, vertical surface roughness of (R-a) 9.2 mu m, and build porosity of 1.4% using an internal contour of 150 mu m and energy density of 35.7 J/mm(3).
引用
收藏
页码:144 / 155
页数:12
相关论文
共 50 条
  • [1] Tailoring Selective Laser Melting Process Parameters for NiTi Implants
    Bormann, Therese
    Schumacher, Ralf
    Mueller, Bert
    Mertmann, Matthias
    de Wild, Michael
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2012, 21 (12) : 2519 - 2524
  • [2] Tailoring Selective Laser Melting Process Parameters for NiTi Implants
    Therese Bormann
    Ralf Schumacher
    Bert Müller
    Matthias Mertmann
    Michael de Wild
    Journal of Materials Engineering and Performance, 2012, 21 : 2519 - 2524
  • [3] Fabrication of titanium dental implants by selective laser melting
    Santos, E
    Osakada, K
    Shiomi, M
    Morita, M
    Abe, F
    FIFTH INTERNATIONAL SYMPOSIUM ON LASER PRECISION MICROFABRICATION, 2004, 5662 : 268 - 273
  • [4] An integrated approach of topology optimized design and selective laser melting process for titanium implants materials
    Xiao, Dongming
    Yang, Yongqiang
    Su, Xubin
    Wang, Di
    Sun, Jianfeng
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2013, 23 (05) : 433 - 445
  • [5] An in vitro Study on the Biocompatibility of Titanium Implants Made by Selective Laser Melting
    Ilea, Aranka
    Timus, Daniela
    Petrescu, Nausica Bianca
    Soritau, Olga
    Bosca, Bianca Adina
    Mager, Voicu
    Barbu-Tudoran, Lucian
    Babtan, Anida Maria
    Campian, Radu Septimiu
    Barabas, Reka
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2019, 24 (05) : 782 - 792
  • [6] An in vitro Study on the Biocompatibility of Titanium Implants Made by Selective Laser Melting
    Aranka Ilea
    Daniela Timuş
    Nausica Bianca Petrescu
    Olga Soriţău
    Bianca Adina Boşca
    Voicu Mager
    Lucian Barbu-Tudoran
    Anida Maria Băbţan
    Radu Septimiu Câmpian
    Réka Barabás
    Biotechnology and Bioprocess Engineering, 2019, 24 : 782 - 792
  • [7] Surface Modification of Porous Titanium and Titanium Alloy Implants Manufactured by Selective Laser Melting: A Review
    Liu, Weijun
    Li, Wanqiu
    Wang, Huiru
    Bian, Hongyou
    Zhang, Kai
    ADVANCED ENGINEERING MATERIALS, 2023, 25 (21)
  • [8] Biomineralization stimulated peri-titanium implants prepared by selective laser melting
    Liu, Jingyin
    Han, Guang
    Pan, Shaoxia
    Ge, Yanjun
    Feng, Hailan
    Shen, Zhijian
    JOURNAL OF MATERIOMICS, 2015, 1 (03) : 253 - 261
  • [9] A COMPARATIVE STUDY ON SELECTIVE LASER MELTING AND ELECTRON BEAM MELTING PROCESS FOR ORTHOPEDIC IMPLANTS
    Rafi, H. Khalid
    Sing, Swee Leong
    Jia, An
    Yee, Yeong Wai
    Fai, Leong Ka
    PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON PROGRESS IN ADDITIVE MANUFACTURING, 2014, : 91 - +
  • [10] Determining the tribological behavior of 316L stainless steel with lubricating micro-channels produced by the selective laser melting (SLM) method
    Turalioglu, Kerem
    Taftali, Merve
    Yetim, Fatih
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2021, 73 (05) : 700 - 707