High frequency power supply to improve operation stability of linear electron accelerator

被引:0
|
作者
Shilov, Vladimir Kuzmich [1 ]
Filatov, Aleksandr Nikolaevich [1 ]
Novozhilov, Aleksandr Evgenevich [1 ]
机构
[1] Natl Res Nucl Univ MEPhI, Moscow Engn Phys Inst, Moscow 115409, Russia
来源
NEXO REVISTA CIENTIFICA | 2021年 / 34卷 / 04期
关键词
Linear Electron Accelerator; Biperiodic Slowing System; Standing Wave; Phase Shifter; Generator; T-Junction; Waveguide Bridge;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The use of linear electron accelerators in medicine and industry is explained by the simplicity of the input and output of accelerated electrons and adjusting the energy and dose rate, as well as the high dose rate of bremsstrahlung. The purpose of this work is to increase the stability of their work. A standing wave accelerator containing a high-frequency generator, a phase shifter, a waveguide bridge, a high-frequency load, and an accelerating system of two accelerating sections is equipped with two waveguide tees. Their inputs are connected to the output arms of the waveguide bridge, and the first and second output arms of each tee are connected to the first and last accelerating cells of each section, respectively. In this system, due to the introduction of several elements that do not require large costs for manufacturing and tuning, a significantly greater frequency separation of the operating mode of oscillations from neighboring ones is ensured, or even a single-frequency excitation mode is implemented, which makes it possible to significantly increase the stability of the accelerator operation. This technique can be used to increase the stability of operation in the design and calculation of linear accelerators of electrons with a standing wave.
引用
收藏
页码:1515 / 1520
页数:6
相关论文
共 50 条
  • [1] PRELIMINARY RESULTS - OPERATION OF A HIGH POWER ELECTRON LINEAR ACCELERATOR
    POST, RF
    PHYSICAL REVIEW, 1950, 78 (01): : 92 - 92
  • [2] OPERATION OF A LINEAR ELECTRON ACCELERATOR
    BECKER, GE
    CASWELL, DA
    PHYSICAL REVIEW, 1949, 76 (04): : 587 - 587
  • [3] High-frequency gun for an electron linear accelerator
    Ajzatskij, N.I.
    Bisler, E.Z.
    Dovbnya, A.N.
    Kushnir, V.A.
    Mitrochenko, V.V.
    Pribory i Tekhnika Eksperimenta, 1997, (01): : 34 - 38
  • [4] IMPROVEMENT IN STABILITY OF POWER SUPPLY SYSTEM FOR MAGNETS OF CAMBRIDGE ELECTRON ACCELERATOR
    PALLOTTINO, GV
    NUCLEAR INSTRUMENTS & METHODS, 1966, 42 (01): : 163 - +
  • [5] Adjustment of High Frequency Properties of Linear Electron Accelerator.
    Novozhilov, Aleksandr Evgen'evich
    Filatov, Aleksandr Nikolaevich
    Shilov, Vladimir Kuz'mich
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2016, 7 (03): : 2681 - +
  • [7] HIGHER FREQUENCY OPERATION OF LINEAR-ACCELERATOR
    MIYAHARA, A
    KAWASAKI, S
    KOBAYASHI, N
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (02): : 167 - 167
  • [8] HIGHER FREQUENCY OPERATION OF LINEAR-ACCELERATOR
    KOBAYASHI, N
    MIYAHARA, A
    KAWASAKI, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) : 3476 - 3478
  • [9] Linear quadratic tracking controller design to improve high frequency power supply system performance
    Li, XY
    Jalali, J
    Foulkes, RH
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 61 - I AND II, 1999, 61 : 446 - 451
  • [10] INITIAL OPERATION OF MIT ELECTRON LINEAR ACCELERATOR
    HAIMSON, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (03) : 914 - 918