Exploring Eye-tracking Technology as an Assessment Tool for Point-of-care Ultrasound Training

被引:8
|
作者
Lee, Wei Feng [1 ,2 ]
Chenkin, Jordan [1 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Emergency Dept, Toronto, ON, Canada
[2] Ng Teng Fong Gen Hosp, Emergency Dept, Singapore, Singapore
关键词
EXPERTISE;
D O I
10.1002/aet2.10508
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Eye-tracking technology has emerged as a potentially useful learner assessment tool in several medical specialties. In the fields of general surgery and anesthesiology, it has been shown to reliably differentiate between different levels of expertise in procedural skills. In the field of radiology, it has been shown to be a valid assessment tool for diagnostic test interpretation. Current methods of competency assessment in point-of-care ultrasound (POCUS) remain a challenge, because they require significant direct observation time by an instructor. The purpose of this study was to determine if eye-tracking technology can accurately distinguish between novice and experts in the interpretation of POCUS clips, specifically of the focused assessment using sonography in trauma (FAST) scan. Methods: A convenience sample of medical students, residents, and emergency physicians from a single academic emergency department were invited to participate. Participants included both novices and experts in POCUS. Each participant completed a baseline questionnaire and viewed 16 video clips of a FAST ultrasound examination while their gaze patterns were recorded by a commercially available eye-tracking device. The primary outcome was total gaze time on the area of interest (AOI). Secondary outcomes included total time to fixation, mean number of fixations, and mean duration of first fixation on the AOI. Results: Fifteen novices and 15 experts completed this study. For total gaze time on the AOI, experts fixated their gaze significantly longer than novices (75.8 +/- 16.2 seconds vs. 56.6 +/- 12.8 seconds, p = 0.001). Similarly, experts were significantly faster to fixate on the AOI and had a higher fixation count on the AOI (8.5 +/- 4.0 seconds vs. 15.1 +/- 6.8 seconds, p = 0.003; and 170 +/- 30 vs. 143 +/- 28 seconds, p = 0.016). There were no differences on the mean duration of first fixation on the AOI (0.42 +/- 0.12 seconds vs. 0.39 +/- 0.09 seconds, p = 0.467). Conclusion: Eye-tracking technology shows the potential to differentiate between experts and novices by their gaze patterns on video clips of FAST examinations. The total gaze time on the AOI may be a useful metric to help in the assessment of competency in POCUS image interpretation. In addition, the evaluation of gaze patterns may help educators identify causes of interpretation errors. Future studies are needed to further validate these metrics in a larger cohort.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Point-of-Care Ultrasound: Novel Technology to Routine Perioperative Assessment Tool
    Ramsingh, Davinder
    Gudzenko, Vadim
    Martin, Robert D.
    [J]. ANESTHESIA AND ANALGESIA, 2017, 124 (03): : 709 - 711
  • [2] Eye-Tracking Technology in Surgical Training
    Merali, Nabeel
    Veeramootoo, Darmarajah
    Singh, Sukhpal
    [J]. JOURNAL OF INVESTIGATIVE SURGERY, 2019, 32 (07) : 587 - 593
  • [3] Point-of-care ultrasound training
    Wilkey, Sigismund
    [J]. ULTRASOUND, 2010, 18 (02) : 103 - 103
  • [4] Point-of-Care Ultrasound Training: An Assessment of Interns' Needs and Barriers to Training
    Jarwan, Waleed
    Alshamrani, Abdullah A.
    Alghamdi, Afnan
    Mahmood, Naveed
    Kharal, Yousuf M.
    Rajendram, Rajkumar
    Hussain, Arif
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (10)
  • [5] A National Needs Assessment of Point-of-Care Ultrasound Training for Hospitalists
    LoPresti, Charles M.
    Boyd, Jeremy S.
    Schott, Christopher
    Core, Megan
    Lucas, Brian P.
    Colon-Molero, Angel
    Kessler, Chad
    Mader, Michael J.
    Haro, Elizabeth K.
    Finley, Erin P.
    Restrepo, Marcos I.
    Pugh, Jacqueline
    Soni, Nilam J.
    [J]. MAYO CLINIC PROCEEDINGS, 2019, 94 (09) : 1910 - 1912
  • [6] Training the Anesthesiologist in Point-of-Care Ultrasound
    Deshpande, Ranjit
    Montealegre-Gallegos, Mario
    Matyal, Robina
    Belani, Kiran
    Chawla, Nikhil
    [J]. INTERNATIONAL ANESTHESIOLOGY CLINICS, 2016, 54 (01) : 71 - 93
  • [7] Training medical students in physical examination and point-of-care ultrasound: An assessment of the needs and barriers to acquiring skills in point-of-care ultrasound
    Rajendram, Rajkumar
    Alrasheed, Abdullah O.
    Boqaeid, Abdulaziz A.
    Alkharashi, Faris K.
    Qasim, Salman S.
    Hussain, Arif
    [J]. JOURNAL OF FAMILY AND COMMUNITY MEDICINE, 2022, 29 (01): : 62 - 70
  • [8] Point-of-care ultrasound: An emerging clinical tool to enhance physical assessment
    Fraleigh, Courteney D. M.
    Duff, Elsie
    [J]. NURSE PRACTITIONER, 2022, 47 (08): : 14 - 20
  • [9] Eye-tracking as diagnosis and assessment tool for social phobia
    Grillon, Helena
    Riquier, Francoise
    Thalmann, Daniel
    [J]. 2007 VIRTUAL REHABILITATION, 2007, : 136 - +
  • [10] Assessment of changes in gaze patterns during training in point-of-care ultrasound
    Chan, Alice H. Y.
    Lee, Wei Feng
    Van Gerven, Pascal W. M.
    Chenkin, Jordan
    [J]. BMC MEDICAL EDUCATION, 2022, 22 (01)