CAD system for full-digital mammography and its evaluation

被引:6
|
作者
Kobatake, H
Okuno, K
Murakami, M
Ishida, M
Takeo, H
Nawano, S
机构
关键词
breast cancer; mammography; CAD; malignant tumors; microcalcifications; iris filter; morphological processing;
D O I
10.1117/12.274161
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The purpose of this study is to develop a clinical intelligent workstation for computer-aided diagnosis (CAD) of breast cancer using fall digital mammography. It consists of a clinical workstation and Fuji Computed Radiography 9000 System. New image processing methods to extract tumor masses and clustered microcalcifications have been developed and implemented in the CAD system. A new filter called Iris Filter has been developed to detect tumor candidates. It realizes reliable detection of tumor candidates regardless of their sizes and their contrast against their background on mammograms. And a new method based on mathematical morphology has been developed to detect microcalcifications. It is adaptive to the imaging conditions of mammograms. One thousand, two hundred and twelve CR images, which include 240 malignant tumors, were used to test the performance of the system. The sensitivity for malignant tumors was 90.5% and the average number of false positives per image were only 1.3. The true positive detection rate for clustered microcalcifications was 89.2% and the average number of false positives per image were 0.36. The high true positive rates and the low false positive detection characterize the proposed full-digital CAD system, which shows the possibility of practical application of computer aided diagnosis of breast cancer.
引用
收藏
页码:745 / 752
页数:8
相关论文
共 50 条
  • [1] Tumor detection system for full-digital mammography
    Kobatake, H
    Takeo, H
    Nawano, S
    DIGITAL MAMMOGRAPHY, 1998, 13 : 87 - 94
  • [2] Microcalcification detection system for full-digital mammography
    Kobatake, H
    Takeo, H
    Nawano, S
    DIGITAL MAMMOGRAPHY, 1998, 13 : 201 - 204
  • [3] Automated tumor detection system for full-digital mammography using bilateral comparison in feature space
    Hashimoto, S
    Kobatake, H
    Takeo, H
    Nawano, S
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 207 - 212
  • [4] Evaluation of a wavelet-based CAD system for detecting and enhancing microcalcifications in full field digital mammography
    Diekmann, F
    Diekmann, SD
    Schneider, W
    Drexl, J
    Heinlein, P
    Hamm, BK
    RADIOLOGY, 2001, 221 : 425 - 425
  • [5] DQE evaluation of a full-field digital mammography system
    Roehrig, H
    Gandhi, K
    Fan, JH
    Poolla, A
    Mimura, S
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS VI, 2004, 5541 : 141 - 152
  • [6] Clinical evaluation of a full-digital in-the-ear hearing instrument
    Boymans, M
    Dreschler, WA
    Schoneveld, P
    Verschuure, H
    AUDIOLOGY, 1999, 38 (02): : 99 - 108
  • [7] Impact of CAD with Full Field Digital Mammography on Workflow and Cost
    Taylor, Paul
    Potts, Henry
    Wilkinson, Louise
    Given-Wilson, Rosalind
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 1 - +
  • [8] Developing full-digital servo system for RSP based on PMAC
    Zhang, Xuhui
    Ma, Hongwei
    Tong, Juan
    2007 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS I-V, CONFERENCE PROCEEDINGS, 2007, : 2404 - 2408
  • [9] Downlink Wideband Channel Estimation for Asymmetrical Full-Digital System
    Lu, Jiacheng
    Zhang, Jun
    Cai, Shu
    Li, Bin
    Zhu, Xiaowei
    Hong, Wei
    IEEE WIRELESS COMMUNICATIONS LETTERS, 2022, 11 (09) : 1830 - 1834
  • [10] BiCMOS Implementation of a Full-digital Linearized System for Complex Modulation Transmitter
    Gutierrez, Jorge
    Ariaudo, Myriam
    Pache, Denis
    Gautier, Jean-Luc
    Berland, Corinne
    40TH EUROPEAN MICROWAVE CONFERENCE, 2010, : 276 - 279