Reduction of the barium concentration present in liquid efluents by mean of non-dispersive extraction in hollow fiber modules

被引:0
|
作者
Yaruro, Gladys Duperle [1 ]
Pena, Dario Yesid [1 ]
Hernandez, Humberto Escalante [1 ]
机构
[1] Univ Ind Santander, Escuela Ingn Quim UIS, Santander, Spain
来源
DYNA-COLOMBIA | 2008年 / 75卷 / 155期
关键词
barium; heavy metals; Non-Dispersive Extraction; DEPHA; microporous hollow fiber;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work has been focused on the study of the viability of Barium removal, present in a waste liquid phase, by means of Non-Dispersive Extraction (NDE) in Hollow Fiber Modules. An organic solution based on DEPHA (Bis-2-ethylhexyl phosphate) 30% (v/v), Isopropilic Alcohol 30% (v/v) and Kerosene is used as selective extraction medium. For the extraction process was made a contactor with five hollow microporous propilenic fibers. A solution contained 100 ppm of BaCl2.H2O, level concentration very equal as generated on the petroleum industrial wastes, is used as liquid phase. A efficiency of 95,25% is obtained when the NDE take place at pH = 9, and them 9 hours of process.
引用
收藏
页码:133 / 144
页数:12
相关论文
共 37 条
  • [1] Modelling of liquid-liquid non-dispersive extraction processes in hollow fiber modules.
    Escalante, H
    Alonso, AI
    Ortíz, I
    Irabien, A
    INTERNATIONAL SYMPOSIUM ON LIQUID-LIQUID TWO PHASE FLOW AND TRANSPORT PHENOMENA, 1998, : 155 - 164
  • [2] Non-dispersive liquid extraction of Cr(VI) by TBP/Aliquat 336 using chitosan-made hollow fiber
    Vincent, T
    Guibal, E
    SOLVENT EXTRACTION AND ION EXCHANGE, 2000, 18 (06) : 1241 - 1260
  • [3] CFD simulation of copper(II) extraction with TFA in non-dispersive hollow fiber membrane contactors
    Amir Muhammad
    Mohammad Younas
    Mashallah Rezakazemi
    Environmental Science and Pollution Research, 2018, 25 : 12053 - 12063
  • [4] CFD simulation of copper(II) extraction with TFA in non-dispersive hollow fiber membrane contactors
    Muhammad, Amir
    Younas, Mohammad
    Rezakazemi, Mashallah
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (12) : 12053 - 12063
  • [5] Computational modelling of non-dispersive solvent extraction of uranium in hollow fiber contactor operated in recycle mode
    Swain, Biswajit
    Sarkar, S.
    Singh, K. K.
    Pabby, Anil Kumar
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2021, 161
  • [6] Non-dispersive solvent extraction of neodymium using a hollow fiber contactor: Mass transfer and modeling studies
    Ambare, D. N.
    Ansari, S. A.
    Anitha, M.
    Kandwal, P.
    Singh, D. K.
    Singh, H.
    Mohapatra, P. K.
    JOURNAL OF MEMBRANE SCIENCE, 2013, 446 : 106 - 112
  • [7] Mass Transfer Enhancement in Non-Dispersive Solvent Extraction with Helical Hollow Fiber Enabling Dean Vortices
    Kong, Qingran
    Cheng, Youwei
    Wang, Lijun
    Li, Xi
    AICHE JOURNAL, 2017, 63 (08) : 3479 - 3490
  • [8] Non-Dispersive Solvent Extraction and Stripping of Neodymium (III) using a Hollow Fiber Contactor with TODGA as the Extractant
    Patil, C. B.
    Ansari, S. A.
    Mohapatra, P. K.
    Natarajan, V.
    Manchanda, V. K.
    SEPARATION SCIENCE AND TECHNOLOGY, 2011, 46 (05) : 765 - 773
  • [9] Extraction and stripping of uranium(VI) from nitric acid solution by non-dispersive extraction using a hollow fiber contactor
    Manchanda, V. K.
    Patil, C. B.
    Mohapatra, P. K.
    Gurba, P. B.
    Janardan, P.
    Changrani, R. D.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 232 : 896 - 896
  • [10] Comparative performance of non-dispersive solvent extraction using a single module and the integrated membrane process with two hollow fiber contactors
    Kumar, A
    Haddad, R
    Alguacil, FJ
    Sastre, AM
    JOURNAL OF MEMBRANE SCIENCE, 2005, 248 (1-2) : 1 - 14