Glenoid morphology and the safe zone for protecting the suprascapular nerve during baseplate fixation in reverse shoulder arthroplasty

被引:11
|
作者
Yang, Yuhui [1 ]
Zuo, Jianlin [1 ]
Liu, Tong [1 ]
Shao, Pu [1 ]
Wu, Haihe [1 ]
Gao, Zhongli [1 ]
Xiao, Jianlin [1 ]
机构
[1] Jilin Univ, Dept Orthopaed, China Japan Union Hosp, Changchun, Jilin, Peoples R China
关键词
Reverse total shoulder arthroplasty; Morphological measurement; Screwplacement; Three-dimensional reconstruction; Suprascapular nerve; INJURY; SIZE; ACCURACY; POSITION; ANATOMY; SURGERY; PATIENT; VERSION;
D O I
10.1007/s00264-017-3646-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this study was to investigate glenoid morphology and define the safe zone for protecting the suprascapular nerve baseplate screw during baseplate fixation in reverse shoulder arthroplasty (RSA) in a Chinese population. Methods Shoulder computed tomography (CT) scans from 56 subjects were retrospectively reviewed. Three-dimensional (3D) reconstruction was performed using Mimics software, and corresponding bony references were used to evaluate glenoid morphology. To standardize evaluation, the coronal scapular plane was defined. Safe fixation distances and screw placements were investigated by constructing a simulated cutting plane of the baseplate during RSA. Results Mean glenoid height was 35.83 +/- 2.95 mm, and width was 27.32 +/- 2.78 mm, with significant sexual dimorphism (p < 0.01). According to the cutting plane morphology, the average baseplate radius was 13.84 +/- 1.34 mm. The distances from the suprascapular notch and from two bony reference points at the base of the scapular spine to the cutting plane were 30.27 +/- 2.77 mm, 18.39 +/- 1.67 mm and 16.52 +/- 1.52 mm, respectively, with a gender-related difference. Based on the clock face indication system, the danger zone caused by the suprascapular nerve projection was oriented between the two o'clock and eight o'clock positions in reference to the right shoulder. Conclusion Glenoid size and the safe zone for screw fixation during RSA were characterized in a Chinese population. Careful consideration of baseplate fixation and avoidance of suprascapular nerve injury are important for improved clinical outcome.
引用
收藏
页码:587 / 593
页数:7
相关论文
共 50 条
  • [1] Glenoid morphology and the safe zone for protecting the suprascapular nerve during baseplate fixation in reverse shoulder arthroplasty
    Yuhui Yang
    Jianlin Zuo
    Tong Liu
    Pu Shao
    Haihe Wu
    Zhongli Gao
    Jianlin Xiao
    International Orthopaedics, 2018, 42 : 587 - 593
  • [2] Risk of suprascapular nerve injury during glenoid baseplate fixation for reverse total shoulder arthroplasty: a cadaveric study
    Vance, Danica D.
    O'Donnell, Jeffrey A.
    Baldwin, Edward L.
    Cheah, Jonathan W.
    Pereira, Gregory
    Klifto, Christopher
    Lassiter, Tally E.
    Anakwenze, Oke A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (03) : 532 - 537
  • [3] The effect of glenoid bone loss on reverse shoulder arthroplasty baseplate fixation
    Formaini, Nathan T.
    Everding, Nathan G.
    Levy, Jonathan C.
    Santoni, Brandon G.
    Nayak, Aniruddh N.
    Wilson, Cooper
    Cabezas, Andres F.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (11) : E312 - E319
  • [4] Effect of glenoid perforation during total shoulder arthroplasty on glenoid component cement fixation and suprascapular nerve
    Pace, Gregory, I
    Thomas, Rachel A.
    Zale, Connor L.
    Lewis, Gregory S.
    Kim, Raymond Y.
    Kim, H. Mike
    SHOULDER & ELBOW, 2021, 13 (03) : 276 - 282
  • [5] Does glenoid baseplate geometry affect its fixation in reverse shoulder arthroplasty?
    James, Jaison
    Huffman, Kayla R.
    Werner, Frederick W.
    Sutton, Levi G.
    Nanavati, Vipul N.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (07) : 917 - 924
  • [6] Revision reverse shoulder arthroplasty for glenoid baseplate failure after primary reverse shoulder arthroplasty
    Holcomb, Jason O.
    Cuff, Derek
    Petersen, Steve A.
    Pupello, Derek R.
    Rankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (05) : 717 - 723
  • [7] Reverse Shoulder Arthroplasty Glenoid Fixation
    Friedman, Richard J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (04) : E91 - E91
  • [8] Central fixation element type and length affect glenoid baseplate micromotion in reverse shoulder arthroplasty
    Torkan, Lawrence F.
    Bryant, John T.
    Bicknell, Ryan T.
    Ploeg, Heidi-Lynn
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (07) : 1385 - 1392
  • [9] A Comparison of Central Screw versus Post for Glenoid Baseplate Fixation in Reverse Shoulder Arthroplasty Using a Lateralized Glenoid Design
    Bercik, Michael J.
    Werner, Brian C.
    Sears, Benjamin W.
    Gobezie, Reuben
    Lederman, Evan
    Denard, Patrick J.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (13)
  • [10] Response "Reverse shoulder arthroplasty glenoid fixation''
    Werner, Frederick W.
    Sutton, Levi G.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (04) : E92 - E93