Limited accuracy of dose calculation for large fields at deep depths using the BrainSCAN v5.21 treatment-planning system

被引:1
|
作者
Hsi, Wen C.
Zhang, Yunkai
Kirk, Michael C.
Bernard, Damian
Chu, James C. H.
机构
[1] Rush Univ, Med Ctr, Dept Phys Med, Chicago, IL 60612 USA
[2] Rush Univ, Med Ctr, Dept Radiat Oncol, Chicago, IL 60612 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2005年 / 6卷 / 02期
关键词
radiation treatment-planning system; BrainSCAN; BrainLAB; quality assurance;
D O I
10.1120/jacmp.2024.25333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Varian 120 multileaf collimator (MLC) has a leaf thickness of 5 mm projected at the isocenter plane and can deliver a radiation beam of large field size ( up to 30 cm) to be used in intensity-modulated radiotherapy (IMRT). Often the dose must be delivered to depths greater than 20 cm. Therefore, during the commissioning of the BrainSCAN v5.21 or any radiation treatment-planning (RTP) systems, extensive testing of dose and monitor unit calculations must encompass the field sizes ( 1 cm to 30 cm) and the prescription depths ( 1 cm to 20 cm). Accordingly, the central-axis percent depth doses (PDDs) and off-axis percentage profiles must be measured at several depths for various field sizes. The data for this study were acquired with a 6-MV X-ray beam from a Varian 2100EX LINAC with a water phantom at a source-to-surface distance (SSD) of 100 cm. These measurements were also used to generate a photon beam module, based on a photon pencil beam dose-calculation algorithm with a fast-Fourier transform method. To commission the photon beam module used in our BrainSCAN RTP system, we performed a quantitative comparison of measured and calculated central-axis depth doses and off-axis profiles. Utilizing the principles of dose difference and distance-to-agreement introduced by Van Dyk et al. [ Commissioning and quality assurance of treatment planning computers. Int J Radiat Oncol Biol Phys. 1993; 26: 261- - 273], agreements between calculated and measured doses are < 2% and < 2 mm for the regions of low- and high-dose gradients, respectively. However, large errors ( up to similar to 5% and similar to 7% for 20-cm and 30-cm fields, respectively, at the depth 20 cm) were observed for monitor unit calculations. For a given field size, the disagreement increased with the depth. Similarly, for a given depth the disagreement also increased with the field size. These large systematic errors were caused by using the tissue maximum ratio (TMR) in BrainSCAN v5.21 without considering increased field size as depth increased. These errors have been reported to BrainLAB.
引用
收藏
页码:12 / 18
页数:7
相关论文
共 50 条
  • [1] Accuracy evaluation of dose calculation of ISOgray treatment planning system in wedged treatment fields
    Raghavi, S.
    Sadoughi, H. R.
    Ravari, M. E.
    Mansoury, M. A. Tajik
    Behmadi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 22 (02): : 303 - 308
  • [2] Assessment of a Commercial Treatment Planning System Dose Calculation Accuracy for Small Static Fields
    Bustos, L. Maduro
    Chang, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E703 - E703
  • [3] Evaluation of Dose Calculation Algorithms Accuracy for ISOgray Treatment Planning System in Motorized Wedged Treatment Fields
    Raghavi, Sajjad
    Sadoughi, Hamid-Reza
    Ravari, Mohammad Ehsan
    Behmadi, Marziyeh
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2024, 14 (10):
  • [4] Evaluation of dose calculation accuracy of a commercial radiotherapy treatment planning system for adjacent radiation fields
    Rasouli, Ali
    Arani, Mahmud Naraqi
    Aliasgharzadeh, Akbar
    Farhood, Bagher
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22
  • [5] Accuracy of Dose Calculation for Hemibody Treatments at Extended Distance Using a Commercial Treatment Planning System
    Batta, Yashvardhan
    Juhasz, Janos
    Farrell, Tom
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (02) : 261 - 271
  • [6] Experimental evaluation of the accuracy of skin dose calculation for a commercial treatment planning system
    Court, Laurence E.
    Tishler, Roy B.
    Allen, Aaron M.
    Xiang, Hong
    Makrigiorgos, Mike
    Chin, Lee
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (01): : 29 - 35
  • [7] Accuracy of Dose Calculation Algorithms in MultiPlan Treatment Planning System in Presence of Heterogeneities
    Moignier, C.
    Huet, C.
    Barraux, V.
    Loiseau, C.
    Sebe-Mercier, K.
    Batalla, A.
    Makovicka, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 372 - +
  • [8] Evaluation of Treatment Planning System Dose Calculation in Irregular Rectangular Small Fields
    Qureshi, A.
    Sperling, N.
    MEDICAL PHYSICS, 2017, 44 (06) : 2964 - 2964
  • [9] A SYSTEM OF DOSE CALCULATION AND TREATMENT PLANNING USING INDEPENDENT JAW
    KHAN, FM
    GERBI, BJ
    DEIBEL, FC
    MEDICAL PHYSICS, 1985, 12 (04) : 508 - 508
  • [10] Dosimetric effects of a repositioning head frame system and treatment planning system dose calculation accuracy
    Ferrer, Carlos
    Huertas, Concepcion
    Plaza, Rodrigo
    Aza, Zulima
    Corredoira, Eva
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 124 - 132