Hemodynamics and myocardial blood flow patterns after placement of a cardiac passive restraint device in a model of dilated cardiomyopathy

被引:8
|
作者
Dixon, Jennifer A. [1 ,2 ]
Goodman, Amy M. [3 ]
Gaillard, William F., II [1 ,2 ]
Rivers, William T. [1 ,2 ]
McKinney, Richard A. [1 ,2 ]
Mukherjee, Rupak [1 ,2 ]
Baker, Nathaniel L. [4 ]
Ikonomidis, John S. [3 ]
Spinale, Francis G. [1 ,2 ]
机构
[1] Med Univ S Carolina, Div Cardiothorac Surg, Charleston, SC 29425 USA
[2] Ralph H Johnson Vet Affairs Med Ctr, Charleston, SC USA
[3] Paracor Med Inc, Sunnyvale, CA USA
[4] Med Univ S Carolina, Dept Biostat & Epidemiol, Charleston, SC 29425 USA
来源
基金
美国国家卫生研究院;
关键词
INDUCED HEART-FAILURE; TACHYCARDIA-INDUCED CARDIOMYOPATHY; FUNCTIONAL MITRAL REGURGITATION; CONVERTING ENZYME-INHIBITION; ACORN CLINICAL-TRIAL; SUPPORT DEVICE; COMBINATION THERAPY; INFARCTION; REDUCTION; ADENOSINE;
D O I
10.1016/j.jtcvs.2010.09.065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The present study examined a cardiac passive restraint device which applies epicardial pressure (HeartNet Implant; Paracor Medical, Inc, Sunnyvale, Calif) in a clinically relevant model of dilated cardiomyopathy to determine effects on hemodynamic and myocardial blood flow patterns. Methods: Dilated cardiomyopatht was established in 10 pigs (3 weeks of atrial pacing, 240 beats/min). Hemodynamic parameters and regional left ventricular blood flow were measured under baseline conditions and after acute placement of the HeartNet Implant. Measurements were repeated after adenosine infusion, allowing maximal coronary vasodilation and coronary flow reserve to be determined. Results: Left ventricular dilation and systolic dysfunction occurred relative to baseline as measured by echocardiography. Left ventricular end-diastolic dimension increased and left ventricular fractional shortening decreased (3.8 +/- 0.1 vs 6.1 +/- 0.2 cm and 31.6% +/- 0.5% vs 16.2% +/- 2.1%, both P < .05, respectively), consistent with the dilated cardiomyopathy phenotype. The HeartNet Implant was successfully deployed without arrhythmias and a computed median mid-left ventricular epicardial pressure of 1.4 mm Hg was applied by the HeartNet Implant throughout the cardiac cycle. Acute HeartNet placement did not adversely affect steady state hemodynamics. With the HeartNet Implant in place, coronary reserve was significantly blunted. Conclusions: In a large animal model of dilated cardiomyopathy, the cardiac passive restraint device did not appear to adversely affect basal resting myocardial blood flow. However, after acute HeartNet Implant placement, left ventricular maximal coronary reserve was blunted. These unique results suggest that cardiac passive restraint devices that apply epicardial transmural pressure can alter myocardial blood flow patterns in a model of dilated cardiomyopathy. Whether this blunting of coronary reserve holds clinical relevance with chronic passive restraint device placement remains unestablished. (J Thorac Cardiovasc Surg 2011;142:1038-45)
引用
收藏
页码:1038 / 1045
页数:8
相关论文
共 50 条
  • [1] Hemodynamics and Myocardial Blood Flow Patterns Following Placement of a Cardiac Passive Restraint Device in a Model of Dilated Cardiomyopathy
    Dixon, Jennifer A.
    Goodman, Amy M.
    Gaillard, William F.
    Rivers, William T.
    McKinney, Richard A.
    Mukherjee, Rupak
    Baker, Nathaniel L.
    Ikonomidis, John S.
    Spinale, Francis G.
    CIRCULATION, 2010, 122 (21)
  • [2] Myocardial blood flow in dilated cardiomyopathy
    Parodi O.
    Heart Failure Reviews, 1997, 1 (4) : 261 - 269
  • [3] Passive cardiac function is altered in a mouse model of dilated cardiomyopathy
    Omens, JH
    Li, ZJ
    Hunter, JJ
    FASEB JOURNAL, 1998, 12 (04): : A116 - A116
  • [4] Absolute Myocardial Blood Flow in Dilated Cardiomyopathy Does it Matter?
    Neglia, Danilo
    Liga, Riccardo
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (08) : 1709 - 1711
  • [5] Calf blood flow during prolonged tilt in idiopathic dilated cardiomyopathy and after cardiac transplantation
    Galatius, S
    Wroblewski, H
    Sorensen, VB
    Bie, P
    Arendrup, H
    Kastrup, J
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 278 (01): : H239 - H248
  • [6] REGIONAL HETEROGENEITY OF MYOCARDIAL BLOOD-FLOW IN HUMANS WITH DILATED CARDIOMYOPATHY
    ABRAHAM, S
    FISCHMAN, A
    ALPERT, N
    GONZALES, E
    GEWIRTZ, H
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P23 - P23
  • [8] PET Measurement of Absolute Myocardial Blood Flow and LV Function in Dilated Cardiomyopathy
    Gewirtz, Henry
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (05) : 557 - 560
  • [9] Prognostic value of myocardial blood flow impairment in patients with idiopathic dilated cardiomyopathy
    Neglia, D
    Trivieri, MG
    Michelassi, C
    Gallopin, M
    Pratali, L
    Poddighe, R
    Salvadori, P
    Sambuceti, G
    Parodi, O
    L'Abbate, A
    EUROPEAN HEART JOURNAL, 2000, 21 : 426 - 426
  • [10] Myocardial blood flow reserve using myocardial contrast echocardiography is a prognostic indicator in dilated cardiomyopathy
    Kalvaitis, S
    Belcik, T
    Horton, K
    Kaul, S
    Wei, K
    CIRCULATION, 2005, 112 (17) : U695 - U695