Three-dimensional quantification of vorticity and helicity from 3D cine PC-MRI using finite-element interpolations

被引:25
|
作者
Sotelo, Julio [1 ,2 ,3 ]
Urbina, Jesus [1 ,4 ]
Valverde, Israel [5 ,6 ]
Mura, Joaquin [1 ]
Tejos, Cristian [1 ,2 ,7 ,8 ,9 ]
Irarrazaval, Pablo [1 ,2 ,7 ,8 ,9 ]
Andia, Marcelo E. [1 ,4 ,7 ,8 ,9 ]
Hurtado, Daniel E. [3 ,7 ,8 ,9 ]
Uribe, Sergio [1 ,4 ,7 ,8 ,9 ]
机构
[1] Pontificia Univ Catolica Chile, Biomed Imaging Ctr, Marcoleta 367, Santiago, Chile
[2] Pontificia Univ Catolica Chile, Dept Elect Engn, Santiago, Chile
[3] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Sch Med, Dept Radiol, Marcoleta 367, Santiago, Chile
[5] Hosp Virgen del Rocio, Pediat Cardiol Unit, Seville, Spain
[6] Hosp Virgen del Rocio, Inst Biomed Seville IBIS, Cardiovasc Pathol Unit, Seville, Spain
[7] Pontificia Univ Catolica Chile, Inst Biol & Med Engn, Sch Engn, Santiago, Chile
[8] Pontificia Univ Catolica Chile, Inst Biol & Med Engn, Sch Med, Santiago, Chile
[9] Pontificia Univ Catolica Chile, Inst Biol & Med Engn, Sch Biol Sci, Santiago, Chile
关键词
3D cine PC-MRI; vorticity; helicity; finite elements; flow quantification; WALL SHEAR-STRESS; CARDIOVASCULAR MAGNETIC-RESONANCE; BLOOD-FLOW PATTERNS; PHASE-CONTRAST MRI; 4D FLOW; THORACIC AORTA; VORTEX FORMATION; WHOLE-HEART; HEMODYNAMICS; ANEURYSM;
D O I
10.1002/mrm.26687
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeWe propose a 3D finite-element method for the quantification of vorticity and helicity density from 3D cine phase-contrast (PC) MRI. MethodsBy using a 3D finite-element method, we seamlessly estimate velocity gradients in 3D. The robustness and convergence were analyzed using a combined Poiseuille and Lamb-Ossen equation. A computational fluid dynamics simulation was used to compared our method with others available in the literature. Additionally, we computed 3D maps for different 3D cine PC-MRI data sets: phantom without and with coarctation (18 healthy volunteers and 3 patients). ResultsWe found a good agreement between our method and both the analytical solution of the combined Poiseuille and Lamb-Ossen. The computational fluid dynamics results showed that our method outperforms current approaches to estimate vorticity and helicity values. In the in silico model, we observed that for a tetrahedral element of 2mm of characteristic length, we underestimated the vorticity in less than 5% with respect to the analytical solution. In patients, we found higher values of helicity density in comparison to healthy volunteers, associated with vortices in the lumen of the vessels. ConclusionsWe proposed a novel method that provides entire 3D vorticity and helicity density maps, avoiding the used of reformatted 2D planes from 3D cine PC-MRI. Magn Reson Med 79:541-553, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:541 / 553
页数:13
相关论文
共 50 条
  • [1] 3D Quantification of Wall Shear Stress and Oscillatory Shear Index Using a Finite-Element Method in 3D CINE PC-MRI Data of the Thoracic Aorta
    Sotelo, Julio
    Urbina, Jesus
    Valverde, Israel
    Tejos, Cristian
    Irarrazaval, Pablo
    Andia, Marcelo E.
    Uribe, Sergio
    Hurtado, Daniel E.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (06) : 1475 - 1487
  • [2] 3D quantification of wall shear stress using finite-element interpolations from 4D flow MR data in the Thoracic Aorta
    Julio A Sotelo
    Jesus Urbina
    Cristian Tejos
    Israel Valverde
    Daniel E Hurtado
    Sergio Uribe
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [3] 3D quantification of hemodynamics parameters of pulmonary artery and aorta using finite-element interpolations in 4D flow MR data
    Julio A Sotelo
    Jesus Urbina
    Israel Valverde
    Cristian Tejos
    Pablo Irarrazaval
    Daniel E Hurtado
    Sergio Uribe
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [4] Influence of Eddy Current, Maxwell and Gradient Field Corrections on 3D Flow Visualization of 3D CINE PC-MRI Data
    Lorenz, Ramona
    Bock, Jelena
    Snyder, Jeff
    Korvink, Jan G.
    Jung, Bernd A.
    Markl, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (01) : 33 - 40
  • [5] Quantification of epicardial fat using 3D cine Dixon MRI
    Markus Henningsson
    Martin Brundin
    Tobias Scheffel
    Carl Edin
    Federica Viola
    Carl-Johan Carlhäll
    BMC Medical Imaging, 20
  • [6] Quantification of epicardial fat using 3D cine Dixon MRI
    Henningsson, Markus
    Brundin, Martin
    Scheffel, Tobias
    Edin, Carl
    Viola, Federica
    Carlhall, Carl-Johan
    BMC MEDICAL IMAGING, 2020, 20 (01)
  • [7] Three-dimensional quantification of circulation using finite-element methods in four-dimensional flow MR data of the thoracic aorta
    Sotelo, Julio
    Bissell, Malenka M.
    Jiang, Yaxin
    Mella, Hernan
    Mura, Joaquin
    Uribe, Sergio
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) : 1036 - 1045
  • [8] Nonlinear dynamics of three-dimensional belt drives using the finite-element method
    Dufva, Kari
    Kerkkaenen, Kimmo
    Maqueda, Luis G.
    Shabana, Ahmed A.
    NONLINEAR DYNAMICS, 2007, 48 (04) : 449 - 466
  • [9] Three-Dimensional Modeling of Geogrid Pullout Test Using Finite-Element Method
    Amirhosseini, Iman
    Toufigh, Vahid
    Toufigh, Mohammad Mohsen
    Ghazavi-Baghini, Emad
    INTERNATIONAL JOURNAL OF GEOMECHANICS, 2022, 22 (03)
  • [10] Numerical dispersion in the finite-element method using three-dimensional edge elements
    Warren, GS
    Scott, WR
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1998, 18 (06) : 423 - 429