Wind-induced loading and dynamic responses of a row of tall buildings under strong interference

被引:60
|
作者
Lam, K. M. [1 ]
Zhao, J. G. [1 ]
Leung, M. Y. H. [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Interference effect; Dynamic responses; Wind tunnel testing;
D O I
10.1016/j.jweia.2011.02.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper studies wind-induced interference effects on a row of five square-plan tall buildings arranged in close proximity. Mean and fluctuating wind loads are measured on each building member and wind-induced dynamic responses of the building are estimated with the high-frequency force-balance technique. The modifications of building responses from interference over a practical range of reduced velocities are represented by an envelope interference factor. Wind tunnel experiments and response analysis are carried out under all possible angles of wind incidence, at four different building separation distances, and for two arrangement patterns of buildings in the row, that is the parallel and diamond patterns. It is found that building interference leads to amplified dynamic responses in many cases but reduction in responses also occurs at some wind incidence. For a building row of the parallel pattern, five distinct wind incidence sectors of different levels and mechanisms of interference effect can be identified. The largest values of envelope interference factors can reach 2.4 for the torsional responses. When the row of tall buildings is arranged in the diamond pattern, increase in wind excitation occurs at many wind angles due to a "wind catchment" effect. The interference factors have ;larger peak values, reaching 2.1 in the sway directions and above 4 in torsion. However, all large amplifications of building responses do not occur in the situations of peak resonant dynamic responses of the single isolated building. Thus, the design values of peak dynamic responses of a tall building are not significantly magnified when placed in a row. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:573 / 583
页数:11
相关论文
共 50 条
  • [1] Wind-induced interference excitation of tall buildings
    Kwok, KCS
    STRUCTURAL ENGINEERING AND MECHANICS, VOLS 1 AND 2, 1999, : 1693 - 1698
  • [2] Wind-induced responses of tall buildings under combined aerodynamic control
    Zheng, Chaorong
    Xie, Yu
    Khan, Mahram
    Wu, Yue
    Liu, Jing
    ENGINEERING STRUCTURES, 2018, 175 : 86 - 100
  • [3] Interference effects on wind loading of a row of closely spaced tall buildings
    Lam, K. M.
    Leung, M. Y. H.
    Zhao, J. G.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2008, 96 (05) : 562 - 583
  • [4] Research progress of wind-induced interference effects on tall buildings
    Yu, Xianfeng
    Xie, Zhuangning
    Gu, Ming
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (03): : 1 - 11
  • [5] Effect of recessed cavities on wind-induced loading and dynamic responses of a tall building
    Wong, S. Y.
    Lam, K. M.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2013, 114 : 72 - 82
  • [6] Experimental study on wind-induced dynamic interference effects between two tall buildings
    Huang, P
    Gu, M
    WIND AND STRUCTURES, 2005, 8 (03) : 147 - 161
  • [8] Wind-induced responses of tall buildings experiencing complex motion
    Thepmongkorn, S
    Kwok, KCS
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2002, 90 (4-5) : 515 - 526
  • [9] Interference effects on wind-induced responses of super-tall building caused by adjacent buildings
    Huang, Dongmei
    Zhu, Ledong
    Ding, Quanshun
    Tongji Daxue Xuebao/Journal of Tongji University, 2009, 37 (03): : 291 - 297
  • [10] The wind-induced dynamic response of tall buildings, a comparative study
    vanOosterhout, GPC
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 64 (2-3) : 135 - 144