Influences of interior fitting processes on the indoor air quality of two model rooms

被引:4
|
作者
Hoellbacher, Eva [1 ,2 ]
Ters, Thomas [1 ,2 ]
Rieder-Gradinger, Cornelia [1 ,2 ]
Srebotnik, Ewald [2 ]
机构
[1] Wood K Plus, Competence Ctr Wood Composites & Wood Chem, Altenberger Str 69, A-4040 Linz, Austria
[2] Vienna Univ Technol, Inst Chem Engn, Getreidemarkt 9, A-1060 Vienna, Austria
关键词
VOLATILE ORGANIC-COMPOUNDS; VOC EMISSIONS; RESIDENTIAL BUILDINGS; REFERENCE VALUES; WOOD PRODUCTS; FORMALDEHYDE; POLLUTANTS; BEHAVIOR; SORPTION; SITE;
D O I
10.1007/s00107-016-1051-0
中图分类号
S7 [林业];
学科分类号
0829 ; 0907 ;
摘要
Interior fitting was performed stepwise in two model rooms built from Oriented Strand Board (OSB) and Cross Laminated Timber (X-lam), respectively. The walls and ceiling of the OSB model room were covered with gypsum plasterboard, parquet flooring was laid and the room was finally equipped with office furniture and textiles. In the X-lam model room an acoustical ceiling and parquet were installed. The walls were painted with wood stain and the room was adapted as bed room and equipped with textiles. After each fitting step volatile organic compounds (VOC) samples were taken and analyzed. In the OSB model room, the total volatile organic compound (TVOC) concentration decreased throughout the whole fitting process from 119 A mu g m(-3) prior to the interior fitting to a final value of 26 A mu g m(-3). In the X-lam model room, a change of the VOC profile and/or concentration could be observed after each fitting step. The highest TVOC concentration (225 A mu g m(-3)) was reached seven days after the installation of the acoustical ceiling. Terpenes, aldehydes and acetic acid were the most abundant substances identified. It was shown for both model rooms that some of the applied building materials acted as diffusion barriers or as emission sinks.
引用
下载
收藏
页码:693 / 701
页数:9
相关论文
共 50 条
  • [1] Influences of interior fitting processes on the indoor air quality of two model rooms
    Eva Höllbacher
    Thomas Ters
    Cornelia Rieder-Gradinger
    Ewald Srebotnik
    European Journal of Wood and Wood Products, 2016, 74 : 693 - 701
  • [2] Microbiological quality of indoor air in university rooms
    Stryjakowska-Sekulska, M.
    Piotraszewska-Pajak, A.
    Szyszka, A.
    Nowicki, M.
    Filipiak, M.
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2007, 16 (04): : 623 - 632
  • [3] Ventilation to maintain indoor air quality in smoking rooms
    Snelson, D. G.
    Al-Madfai, H.
    Geens, A. J.
    AIR POLLUTION XVIII, 2010, 136 : 339 - 348
  • [4] Evaluation of indoor air quality of residential rooms in Beijing
    Liu, Fang
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [5] A two step model for the assessment of the indoor air quality
    Müller, D
    Bitter, F
    Kasche, J
    Müller, B
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 20 - 25
  • [6] The influence of photocatalytic interior paints on indoor air quality
    Auvinen, Joonas
    Wirtanen, Leif
    ATMOSPHERIC ENVIRONMENT, 2008, 42 (18) : 4101 - 4112
  • [7] Assessment of indoor air quality in interior Alaskan homes
    Johnson, R
    Schmid, J
    Seifert, R
    JOURNAL OF COLD REGIONS ENGINEERING, 2002, 16 (04) : 218 - 229
  • [8] Interior Materials Combination and Perceived Indoor Air Quality
    Senitkova, Ingrid Juhasova
    10TH INTERNATIONAL SCIENTIFIC CONFERENCE BUILDING DEFECTS (BUILDING DEFECTS 2018), 2019, 279
  • [9] Indoor air quality in restaurants with and without designated smoking rooms
    Milz, Sheryl
    Akbar-Khanzadeh, Farhang
    Ames, April
    Spino, Sara
    Tex, Christopher
    Lanza, Kathryn
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2007, 4 (04) : 246 - 252
  • [10] Influence of Surgical Smoke on Indoor Air Quality in Hospital Operating Rooms
    Choi, Dong Hee
    Choi, Seock Hwan
    Kang, Dong Hwa
    AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (03) : 821 - 830