Percutaneous intervention over the origin of a saphenous vein graft anastomosed with the St. Jude Medical Symmetry Aortic Connector System

被引:1
|
作者
Fuertes, J
Lozano, I
Turiel, JM
Llosa, JC
Suarez, E
de la Tassa, CM
机构
[1] Univ Oviedo, Hosp Cent Asturias, Dept Cardiol, Oviedo 33006, Spain
[2] Univ Oviedo, Hosp Cent Asturias, Dept Cardiovasc Surg, Oviedo 33006, Spain
关键词
anastomosis; angioplasty; bypass; revascularization; stents; grafting;
D O I
10.1002/ccd.10703
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We describe a percutaneous intervention performed over the proximal anastomoses of an aortocoronary saphenous vein graft that had been attached to the aorta 3 months before with the St. Jude Medical Symmetry Aortic Connector System. Technical aspects of procedure are discussed, and the experience previously reported in the literature related to this issue is reviewed. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 24 条
  • [1] Skeletonized radial artery graft with the St. Jude Medical Symmetry Bypass System (aortic connector system)
    Watanabe, G
    Takemura, H
    Tomita, S
    Nagamine, H
    Kamiya, H
    Kanamori, T
    ANNALS OF THORACIC SURGERY, 2004, 77 (05): : 1550 - 1552
  • [2] Early clinical results of St. Jude Medical Symmetry aortic connector
    Toyama M.
    Usui A.
    Abe T.
    Yoshikawa M.
    Akita T.
    Ueda Y.
    Journal of Artificial Organs, 2005, 8 (2) : 95 - 99
  • [3] The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting
    Eckstein, FS
    Bonilla, LF
    Englberger, L
    Immer, FF
    Berg, TA
    Schmidli, J
    Carrel, TP
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (04): : 777 - 782
  • [4] Mid-term follow up of patients using the St. Jude Medical Aortic Connector System for proximal vein graft in CABG
    Chung, Cheol Hyun
    Lee, Jae Won
    Kang, Joon Kyu
    Song, Hyun
    Choo, Suk Jung
    Song, Meong Gun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2006, 21 (05) : 849 - 853
  • [5] Prospective Evaluation of the St. Jude Medical Aortic Connector for Aortic-to-Autologous Vessel Graft Anastomoses
    Diegeler, Anno
    Setina, Marek
    Antona, Carlo
    Lakew, Fitsum
    Mokracek, Alex
    Scrofani, Roberto
    Eckstein, Friedrich S.
    Gibson, Michael
    Bonilla, Luis
    Carrel, Thierry
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2005, 1 (02) : 79 - 82
  • [6] Flow dynamics of the St Jude Medical Symmetry aortic connector vein graft anastomosis do not contribute to the risk of acute thrombosis
    Redaelli, A
    Maisano, F
    Ligorio, G
    Cattaneo, E
    Montevecchi, FM
    Alfieri, O
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (01): : 117 - 123
  • [7] First experience with the St Jude Medical, Inc, Symmetry Bypass System (Aortic Connector System)
    Hornik, L
    Tenderich, G
    Minami, K
    Fassbender, D
    Schulz, TO
    Beinert, B
    Koerfer, R
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (02): : 414 - 417
  • [8] An experimental model of saphenous vein-to-coronary artery anastomosis with the St. Jude medical stainless steel connector
    Schaff, HV
    Zehr, KJ
    Bonilla, LF
    Brennecke, LH
    Berg, T
    Cornelius, R
    Hindrichs, P
    Swanson, W
    ANNALS OF THORACIC SURGERY, 2002, 73 (03): : 830 - 835
  • [9] Clinical results using the St. Jude Medical "Symmetry" aortic connector system in 400 coronary artery bypass patients
    Koutlas, TC
    Maziarz, D
    Conquest, A
    Williams, JM
    Scott, WW
    Kypson, AP
    Chitwood, WR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 273A - 273A
  • [10] Total dislodgement of St. Jude Symmetry proximal aortic connector after OPCAB
    Bernstein, RV
    Browdie, DA
    Sacchetti, DD
    Estrada, MD
    HEART SURGERY FORUM, 2003, 6 (04): : E72 - E73