Cryoballoon versus Radiofrequency Catheter Ablation in Atrial Fibrillation: A Meta-Analysis

被引:69
|
作者
Cardoso, Rhanderson [1 ]
Mendirichaga, Rodrigo [1 ]
Fernandes, Gilson [1 ]
Healy, Chris [1 ]
Lambrakos, Litsa K. [1 ]
Viles-Gonzalez, Juan F. [1 ]
Goldberger, Jeffrey J. [1 ]
Mitrani, Raul D. [1 ]
机构
[1] Univ Miami, Jackson Mem Hosp, Dept Med, Div Cardiol, Cent Bldg,Room 600D, Miami, FL 33136 USA
关键词
atrial fibrillation; catheter ablation; complication; cryoballoon; pulmonary vein isolation; radiofrequency; PULMONARY VEIN ISOLATION; OPEN-IRRIGATED RADIOFREQUENCY; HEART RHYTHM ASSOCIATION; 2ND-GENERATION CRYOBALLOON; TERM OUTCOMES; FORCE; EFFICACY; TRIAL;
D O I
10.1111/jce.13047
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cryoballoon vs. Radiofrequency AF Ablation IntroductionRadiofrequency (RF) and cryoballoon (CB) catheter ablation are effective for pulmonary vein isolation (PVI) in atrial fibrillation (AF). This report presents an updated meta-analysis comparing the efficacy and safety of CB versus RF ablations in AF. MethodsDatabases and conference abstracts were systematically searched for studies that directly compared CB and RF PVI, and reported safety or efficacy outcomes in follow-up 12 months. Recurrent atrial tachyarrhythmias (AT) were defined as AF, atrial flutter, or atrial tachycardia. ResultsTwenty-two studies and 8,668 patients were included. Freedom from AT was not significantly different between CB and RF ablations in the pooled population (OR 1.12; 95%CI 0.97-1.29; P = 0.13) and in randomized trials (OR 1.0; 95%CI 0.65-1.56; P = 0.99). Second-generation CB (CB2; 78.1%) and contact-force (CF) sensing RF (78.2%) have improved procedure success rate as compared to first-generation technology (57.9% CB, 58.1% RF). As compared to CF-RF, CB2 demonstrated similar freedom from recurrent AT (OR 1.04; 95%CI 0.71-1.51; P = 0.84). The incidence of pericardial effusions (OR 0.44; 95%CI 0.28-0.69; P < 0.01), tamponade (OR 0.31; 95%CI 0.15-0.64; P < 0.01), and non-AF AT (OR 0.46; 95%CI 0.26-0.83; P < 0.01) were significantly lower with CB ablation, whereas transient phrenic nerve palsy was more incident after CB (OR 7.40; 95%CI 2.56-21.34; P < 0.01). ConclusionThere was comparable freedom from AT between CB and RF in patients with AF undergoing PVI. Additionally, freedom from AT was similar between CB2 and CF-RF. However, CB was associated with a lower incidence of pericardial effusions or tamponade, albeit with a higher rate of transient phrenic nerve palsies.
引用
下载
收藏
页码:1151 / 1159
页数:9
相关论文
共 50 条
  • [1] Efficacy and safety of cryoballoon ablation versus radiofrequency catheter ablation in atrial fibrillation: an updated meta-analysis
    Ma, Honglan
    Sun, Dongdong
    Luan, Hui
    Feng, Wei
    Zhou, Yaqiong
    Wu, Jine
    He, Caiyun
    Sun, Chaofeng
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2017, 13 (03): : 240 - 249
  • [2] Cryoballoon Versus Radiofrequency Catheter Ablation for Atrial Fibrillation
    Wasserlauf, Jeremiah
    Passman, Rod
    Giedrimas, Evaldas
    Shen, Sharon
    Bhave, Prashant
    Patel, Taral
    Bohn, Martha
    Li, Zhi
    Goldberger, Jeffrey
    Arora, Rishi
    Kim, Susan
    Lin, Albert
    Chicos, Alexandru
    Ilkhanoff, Leonard
    Knight, Bradley
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (05) : 568 - 569
  • [3] Comparison of catheter ablation for paroxysmal atrial fibrillation between cryoballoon and radiofrequency: a meta-analysis
    Chen, Chao-feng
    Gao, Xiao-fei
    Duan, Xu
    Chen, Bin
    Liu, Xiao-hua
    Xu, Yi-zhou
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 48 (03) : 351 - 366
  • [4] Comparison of catheter ablation for paroxysmal atrial fibrillation between cryoballoon and radiofrequency: a meta-analysis
    Chao-feng Chen
    Xiao-fei Gao
    Xu Duan
    Bin Chen
    Xiao-hua Liu
    Yi-zhou Xu
    Journal of Interventional Cardiac Electrophysiology, 2017, 48 : 351 - 366
  • [5] Cryoballoon versus Radiofrequency Catheter Ablation for Paroxysmal Atrial Fibrillation
    Wasserlauf, Jeremiah
    Pelchovitz, Daniel J.
    Rhyner, John
    Verma, Nishant
    Bohn, Martha
    Li, Zhi
    Arora, Rishi
    Chicos, Alexandru B.
    Goldberger, Jeffrey J.
    Kim, Susan S.
    Lin, Albert C.
    Knight, Bradley P.
    Passman, Rod S.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (04): : 483 - 489
  • [6] Meta-Analysis Comparing Cryoballoon Versus Radiofrequency as First Ablation Procedure for Atrial Fibrillation
    Fortuni, Federico
    Casula, Matteo
    Sanzo, Antonio
    Angelini, Filippo
    Cornara, Stefano
    Somaschini, Alberto
    Mugnai, Giacomo
    Rordorf, Roberto
    De Ferrari, Gaetano Maria
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 125 (08): : 1170 - 1179
  • [7] Cryoballoon versus radiofrequency ablation for persistent atrial fibrillation: a systematic review and meta-analysis
    Liu, Xiao-Hua
    Gao, Xiao-Fei
    Jin, Chao-Lun
    Chen, Chao-Feng
    Chen, Bin
    Xu, Yi-Zhou
    KARDIOLOGIA POLSKA, 2020, 78 (01) : 20 - 29
  • [8] Comparison of cryoballoon and radiofrequency ablation techniques for atrial fibrillation: a meta-analysis
    Maltoni, Susanna
    Negro, Antonella
    Camerlingo, Maria D.
    Pecoraro, Valentina
    Sassone, Biagio
    Biffi, Mauro
    Boriani, Giuseppe
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2018, 19 (12) : 725 - 738
  • [9] A meta-analysis and cost-minimization analysis of cryoballoon ablation versus radiofrequency ablation for paroxysmal atrial fibrillation
    Nitta, Yoshimi
    Nishimura, Michiko
    Shibahara, Hidetoshi
    Yamane, Teiichi
    JOURNAL OF ARRHYTHMIA, 2024, 40 (04) : 802 - 814
  • [10] Cryoballoon versus radiofrequency ablation for paroxysmal atrial fibrillation: a meta-analysis of randomized controlled trials
    Murray, Marie-Isabel
    Arnold, Ahran
    Younis, Murad
    Varghese, Swaroop
    Zeiher, Andreas Michael
    CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (08) : 658 - 669