Cardiac valve prosthesis flow performances measured by 2D and 3D-stereo particle image velocimetry

被引:0
|
作者
Marassi, M
Castellini, P
Pinotti, M
Scalise, L
机构
[1] Univ Ancona, Dipartimento Meccan, Ancona, Italy
[2] Univ Fed Minas Gerais, Dept Mech Engn, Belo Horizonte, MG, Brazil
关键词
D O I
10.1007/s00348-003-0693-y
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The present paper reports the design and performance tests of a new artificial heart valve test bench that was specially devised to employ Particle Image Velocimetry (PIV) to perform flow analysis. Among the useful characteristics of this new test bench are the repeatable high quality of the developed flow, the generation of time-variable flow with a feedback-controlled actuator, high versatility in changing and controlling the flow parameters (average rate and the beat frequency), and good optical access for PIV measurements. Different chambers and flow conditions have been used to perform tests using 2D-PIV and 3D-StereoPIV. The aim of such tests were to study the fluid dynamical characteristics of mechanical and biological cardiac prostheses, and to evaluate the procedures used to reduce measurement uncertainty due to the 3D components of the pulsatilee flow through the cardiac valve prostheses. It has been possible to observe the evolution of the complete 2D and 3D flow disturbance induced by the valve prostheses for each phase of their cycle on the upstream and downstream volumes.
引用
收藏
页码:176 / 186
页数:11
相关论文
共 50 条
  • [1] Cardiac valve prosthesis flow performances measured by 2D and 3D-stereo particle image velocimetry
    M. Marassi
    P. Castellini
    M. Pinotti
    L. Scalise
    Experiments in Fluids, 2004, 36 : 176 - 186
  • [2] Stereo particle image velocimetry on mechanical heart valve prosthesis
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 922 - 922
  • [3] Comparing Flow in Helical and Straight Stents Using 2D Ultrasound Particle Image Velocimetry
    Ghanbarzadeh-Dagheyan, Ashkan
    van de Velde, Lennart
    Reijnen, Michel M. P. J.
    Versluis, Michel
    Jebbink, Erik Groot
    MEDICAL IMAGING 2023, 2023, 12470
  • [4] Endoscopic 2D particle image velocimetry (PIV) flow field measurements in IC engines
    Dierksheide, U
    Meyer, P
    Hovestadt, T
    Hentschel, W
    EXPERIMENTS IN FLUIDS, 2002, 33 (06) : 794 - 800
  • [5] Endoscopic 2D particle image velocimetry (PIV) flow field measurements in IC engines
    U. Dierksheide
    P. Meyer
    T. Hovestadt
    W. Hentschel
    Experiments in Fluids, 2002, 33 : 794 - 800
  • [6] Study of flow around model of cooling tower by means of 2D Particle Image Velocimetry measurement
    Barraclough, Veronika
    Novotny, Jan
    Safarik, Pavel
    EXPERIMENTAL FLUID MECHANICS 2016 (EFM16 ), 2017, 143
  • [7] 2D μ-Particle Image Velocimetry and Computational Fluid Dynamics Study Within a 3D Porous Scaffold
    Marin, A. Campos
    Grossi, T.
    Bianchi, E.
    Dubini, G.
    Lacroix, D.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (05) : 1341 - 1351
  • [8] 2D µ-Particle Image Velocimetry and Computational Fluid Dynamics Study Within a 3D Porous Scaffold
    A. Campos Marin
    T. Grossi
    E. Bianchi
    G. Dubini
    D. Lacroix
    Annals of Biomedical Engineering, 2017, 45 : 1341 - 1351
  • [9] Digital holography particle image velocimetry for 3D flow measurement
    Wei, RJ
    Shen, GX
    Ding, HQ
    OPTICAL TECHNOLOGY AND IMAGE PROCESSING FOR FLUIDS AND SOLIDS DIAGNOSTICS 2002, 2002, 5058 : 61 - 72
  • [10] Optimizing the Design of a 2D Array Piezoelectric Micromachined Ultrasound Transducer for 3D Echo Particle Image Velocimetry
    Liu, Jessica
    Shandas, Robin
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2329 - 2332