Photoelectrocatalytic oxidation of o-phenols on copper-plated screen-printed electrodes

被引:15
|
作者
Zen, JM [1 ]
Chung, HH [1 ]
Yang, HH [1 ]
Chiu, MH [1 ]
Sue, JW [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
D O I
10.1021/ac030183i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and sensitive detection method based on photoelectrocatalytic oxidation of o-diphenols was demonstrated on a copper-plated screen-printed carbon electrode (designated CuSPE) in pH 8 phosphate buffer solution. The o-diphenols can be detected amperometrically through electrochemical oxidation at a low applied potential of -0.1 V versus Ag/AgCl, where the CuSPE is much less subject to interfering reactions. The mechanism that induces good selectivity of the CuSPE is explained in terms of the formation of a cyclic five-member complex intermediate (Cu-II-o-quinolate). A prototype homemade flow through cell design is described for incorporating the photoelectrode and light source. Electrode irradiation results in a large increase in anodic current. The oxidative photocurrents produced by irradiation increase with light intensity presumably because of the formation of semiconductor Cu2O. The principle used in this study has an opportunity to extend into various research applications.
引用
收藏
页码:7020 / 7025
页数:6
相关论文
共 50 条
  • [1] Selective detection of o-diphenols on copper-plated screen-printed electrodes
    Zen, JM
    Chung, HH
    Kumar, AS
    ANALYTICAL CHEMISTRY, 2002, 74 (05) : 1202 - +
  • [2] Photoelectrochernical oxygen copper-plated screen-printed sensor using carbon electrodes
    Zen, JM
    Song, YS
    Chung, HH
    Hsu, CT
    Kumar, AS
    ANALYTICAL CHEMISTRY, 2002, 74 (23) : 6126 - 6130
  • [3] Flow injection analysis of hydrogen peroxide on copper-plated screen-printed carbon electrodes
    Zen, JM
    Chung, HH
    Kumar, AS
    ANALYST, 2000, 125 (09) : 1633 - 1637
  • [4] Electrochemical investigation of glucose sensor fabricated at copper-plated screen-printed carbon electrodes
    Kumar, AS
    Zen, JM
    ELECTROANALYSIS, 2002, 14 (10) : 671 - 678
  • [5] A capillary electrophoresis end-column amperometric detection system incorporating disposable copper-plated screen-printed carbon electrodes
    Tsai, DM
    Shih, PR
    Tai, HW
    Liu, CY
    Zen, JM
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2005, 52 (04) : 773 - 779
  • [6] Substituent effects on the electrocatalytic oxidation of phenols at preanodized screen-printed carbon electrodes
    Yang, Hsueh-Hui
    Chiu, Mei-Hsin
    Chang, Ko-Ming
    Shih, Ying
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 682 : 172 - 174
  • [7] Screen-printed electrodes
    Nascimento, VB
    Angnes, L
    QUIMICA NOVA, 1998, 21 (05): : 614 - 629
  • [8] Screen-printed copper ion-selective electrodes
    R. Koncki
    Łukasz Tymecki
    Elżbieta Zwierkowska
    Stanisław Głąb
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 393 - 395
  • [9] Screen-Printed Carbon Electrodes with Porous Copper Film
    Metelka, Radovan
    Vlasakova, Pavlina
    XXXII. MODERNI ELEKTROCHEMICKE METODY, 2012, : 73 - 76
  • [10] Screen-printed copper ion-selective electrodes
    Koncki, R
    Tymecki, L
    Zwierkowska, E
    Glab, S
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (04): : 393 - 395