Tibial tray thickness does not significantly increase medial tibial bone resorption: Using tibial bone density as an objective measurement method

被引:5
|
作者
Wong, Daniel Wai-Yip [1 ]
Lee, Qunn-Jid [1 ]
Lo, Chi-Kin [1 ]
Wong, Yiu-Chung [1 ]
Law, Kenneth Wing-Kin [1 ]
Li, Alwin Hok-Yin [1 ]
机构
[1] Yan Chai Hosp, Hosp Author, Total Joint Replacement Ctr, Hong Kong, Peoples R China
来源
KNEE | 2020年 / 27卷 / 02期
关键词
Bone resorption; Total knee replacement; Tibial tray thickness; Stress shielding; Tibial bone density; Digital radiological densitometry; TOTAL KNEE ARTHROPLASTY; MINERAL DENSITY; STANDARD RADIOGRAPHS; FOLLOW-UP; DESIGN; STEMS; HIP;
D O I
10.1016/j.knee.2019.12.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Recent studies have reported the occurrence of medial tibial bone resorption following total knee replacement. One study proposed that a thick tibial tray results in stress shielding and increases the risk of bone resorption, but its findings were based on subjective radiological assessment. This study aimed to verify this hypothesis and to objectively quantify medial tibial bone density by using serial measurements with digital radiological densitometry. Methods: This was a retrospective cohort study involving 140 patients (70 thick tray vs. 70 thin tray) with cobalt-chromium implants with at least 24 months of follow-up. Standard radiographs were reviewed to look for incidence of medial tibial bone loss. Serial measurement of medial tibial bone density was also performed using the method of digital radiological densitometry. Results: There was no significant difference in the incidence of medial tibial bone loss. Both groups showed a significant drop in medial tibial bone density after operation (P < 0.01). Medial tibial bone density of the thick-tray cohort was significantly higher than the thin-tray cohort at one year (93.3 vs. 83.1 Greyscale: P = 0.04), but not at two and three years. Clinical outcomes in terms of postoperative range of motion, Knee Society score and complication rates were similar. Conclusions: Medial tibial bone resorption is a common phenomenon. Implants with thicker tibial trays suffer less than those with thinner trays at one year, but the difference is transient and does not affect dinical outcome. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:572 / 579
页数:8
相关论文
共 50 条
  • [1] Tibial Tray Thickness Significantly Increases Medial Tibial Bone Resorption in Cobalt-Chromium Total Knee Arthroplasty Implants
    Martin, J. Ryan
    Watts, Chad D.
    Levy, Daniel L.
    Miner, Todd M.
    Springer, Bryan D.
    Kim, Raymond H.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (01): : 79 - 82
  • [2] Tibial bone density in athletes with medial tibial stress syndrome: A controlled study
    Ozgurbuz, Cengizhan
    Yuksel, Oguz
    Ergun, Metin
    Islegen, Cetin
    Taskiran, Emin
    Denerel, Nevzad
    Karamizrak, Oguz
    [J]. JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2011, 10 (04) : 743 - 747
  • [3] TIBIAL TRAY AUGMENTATION WITH MODULAR METAL WEDGES FOR TIBIAL BONE STOCK DEFICIENCY
    BRAND, MG
    DALEY, RJ
    EWALD, FC
    SCOTT, RD
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (248) : 71 - 79
  • [4] Various Types of Medial Tibial Bone Resorption after Total Knee Arthroplasty Using a Thick Cobalt Chromium Tibial Baseplate
    Song, Sang Jun
    Lee, Hyun Woo
    Kang, Se Gu
    Bae, Dae Kyung
    Park, Cheol Hee
    [J]. JOURNAL OF KNEE SURGERY, 2022, 35 (04) : 434 - 442
  • [5] Medial cortical bone thickness of the tibial diaphysis in osteoarthritis is related to lower extremity alignment and tibial morphology
    Maeda, Keisuke
    Mochizuki, Tomoharu
    Tanifuji, Osamu
    Katsumi, Ryota
    Kobayashi, Koichi
    Kawashima, Hiroyuki
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [6] Underhang of the tibial component increases tibial bone resorption after total knee arthroplasty
    Gu, ShiZhong
    Kuriyama, Shinichi
    Nakamura, Shinichiro
    Nishitani, Kohei
    Ito, Hiromu
    Matsuda, Shuichi
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1270 - 1279
  • [7] Underhang of the tibial component increases tibial bone resorption after total knee arthroplasty
    ShiZhong Gu
    Shinichi Kuriyama
    Shinichiro Nakamura
    Kohei Nishitani
    Hiromu Ito
    Shuichi Matsuda
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1270 - 1279
  • [8] Paradoxical Change in Subchondral Bone Density in the Medial Compartment of the Proximal Tibial Articular Surface After High Tibial Osteotomy: A Detailed Subchondral Bone Density Analysis
    Fujie, Yuki
    Iwasaki, Koji
    Hamasaki, Masanari
    Suzuki, Yuki
    Matsuoka, Masatake
    Onodera, Tomohiro
    Kondo, Eiji
    Iwasaki, Norimasa
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2024, 52 (09): : 2278 - 2286
  • [9] Low regional tibial bone density in athletes with medial tibial stress syndrome normalizes after recovery from symptoms
    Magnusson, HI
    Ahlborg, HG
    Karlsson, C
    Nyquist, F
    Karlsson, MK
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (04): : 596 - 600
  • [10] A circumferentially flanged tibial tray minimizes bone-tray shear micromotion
    Barker, DS
    Tanner, KE
    Ryd, L