Research on WSNs Topology and Application of Lightning Monitoring in Distribution Lines

被引:1
|
作者
Wang Tieliu [1 ]
Shen, Silei [1 ]
Wang Junjie [1 ]
机构
[1] Beijing Univ Technol Chaoyang, Beijing, Peoples R China
关键词
WSNs; Distribution lines; Lightning monitor;
D O I
10.4028/www.scientific.net/AMR.433-440.5573
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Wireless Sensor Network (WSN) is used for such tasks as surveillance, widespread environmental sampling, security, and health monitoring widely. In this paper, a WSNs topology is proposed for lightning monitoring of distribution lines, which decides the number of nodes, routing protocol and power efficiency. The WSNs is deployed along the distribution line with nodes mounted on tall towers, which is used to monitor the lightning activities and accomplish fault diagnosis. At last, a monitoring system based on WSN is fabricated.
引用
收藏
页码:5573 / 5578
页数:6
相关论文
共 50 条
  • [1] The Research of Topology Control in Wireless Sensor Network Based on The Monitoring of Transmission and Distribution Lines
    Jia Huibin
    Zhang Caixia
    ADVANCES IN MECHATRONICS, AUTOMATION AND APPLIED INFORMATION TECHNOLOGIES, PTS 1 AND 2, 2014, 846-847 : 483 - 487
  • [2] Research on lightning protection of overhead power distribution lines
    Yokoyama, Shigeru
    Sato, Tomoyuki
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (10): : 2317 - 2328
  • [3] Research on Differentiated Lightning Protection of Overhead Distribution Lines under Continuous Lightning Strikes
    Li, Duanjiao
    Sun, Wenxing
    Song, Kunyu
    Zhu, Ruifeng
    Zhong, Zhenxin
    Ding, Tongshu
    Gao, Jiachen
    ENERGIES, 2024, 17 (18)
  • [4] LIGHTNING PROTECTION OF DISTRIBUTION LINES
    MCDERMOTT, TE
    SHORT, TA
    ANDERSON, JG
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) : 138 - 146
  • [5] LIGHTNING FAULTS ON DISTRIBUTION LINES
    PARRISH, DE
    KVALTINE, DJ
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (04) : 2179 - 2186
  • [6] Effect of lightning protection devices for distribution lines based on a field research
    High Voltage and Insulation Group, R and D Center, TEPCO, 4-1, Egasaki-cho, Turumi-ku, Yokohama 230-8510, Japan
    不详
    IEEJ Trans. Power Energy, 2009, 6 (10+815-822):
  • [7] Research on Terminal Layout Method of Lightning Current Distributed Monitoring for Multi Branch 10kV Distribution Lines
    Feng, Ruifa
    Zhang, Yang
    Liao, Minchuan
    He, Xiaomeng
    Qu, Lu
    Li, Huapeng
    Li, Longgui
    Jin, Qingyuan
    He, Xinyi
    2022 12TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS, ICPES, 2022, : 184 - 189
  • [8] Improved Distribution Feeder Topology Against Lightning
    Cabral, Roberto J.
    Gazzana, Daniel S.
    Leborgne, Roberto C.
    Bretas, Arturo S.
    Dias, Guilherme A. D.
    Tello, Marcos
    Morales, John
    Orduna, Eduardo A.
    2013 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XII SIPDA), 2013, : 267 - 272
  • [9] Lightning overvoltages on rural distribution lines
    Piantini, A.
    Duarte, D.M.
    Romero, F.
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (12): : 2564 - 2569
  • [10] Lightning Overvoltages on Rural Distribution Lines
    Piantini, A.
    Duarte, D. M.
    Romero, F.
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 63 - 66