Static and dynamic features of Fourier transform profilometry: A review

被引:46
|
作者
Zappa, Emanuele [1 ]
Busca, Giorgio [1 ]
机构
[1] Politecn Milan, Dipartimento Meccan, I-20156 Milan, Italy
关键词
Fringe projection; Calibration techniques; Uncertainty analysis; Sensitivity analysis; Phase unwrapping; PHASE-UNWRAPPING ALGORITHM; DIGITAL FRINGE PROJECTION; 3-DIMENSIONAL SHAPE MEASUREMENT; SQUARES CALIBRATION METHOD; SELF-CALIBRATION; ZERO SPECTRUM; MEASUREMENT SYSTEMS; CAMERA CALIBRATION; ERROR COMPENSATION; OBJECT;
D O I
10.1016/j.optlaseng.2012.03.008
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fringe projection techniques are very popular among the several profilometry methods proposed in literature. One of their main advantages is that most of them require one image of the object to retrieve its surface. From a theoretical point of view these techniques are based on a simple mathematical model which is at the base of the conversion of the measured quantity (usually the phase map of the image of the grid projected onto an object surface) into the height distribution of the object. However, the practical implementation of the system is not an easy task to be achieved. The mathematical models are often a simplification of the reality and it is valid only under some conditions. These discrepancies between the theory and the practice deal to a series of discussions about the quality of the measure of fringe projection techniques. This paper proposes a wide argumentation about the measurement uncertainty and the source of error which is influenced by. After a concise description of the triangulation model and of the basic idea of the system working, the measurement techniques are analyzed both from a static and a dynamic point of view, with a special attention to the uncertainty sources in the two measurement conditions and the possible improvements that may be applied to reduce their influence. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1140 / 1151
页数:12
相关论文
共 50 条
  • [1] Fourier transform profilometry: a review
    Su, XY
    Chen, WJ
    OPTICS AND LASERS IN ENGINEERING, 2001, 35 (05) : 263 - 284
  • [2] Fourier transform profilometry for Dynamic 3-D shape
    Su, XY
    Chen, WJ
    PROCESS CONTROL AND INSPECTION FOR INDUSTRY, 2000, 4222 : 245 - 248
  • [3] Improved composite Fourier transform profilometry
    Wu, Ying-chun
    Cao, Yi-ping
    Huang, Zhen-fen
    Lu, Ming-teng
    Chen, De-liang
    OPTICS AND LASER TECHNOLOGY, 2012, 44 (07): : 2037 - 2042
  • [4] Improved Fourier-transform profilometry
    Mao, Xianfu
    Chen, Wenjing
    Su, Xianyu
    APPLIED OPTICS, 2007, 46 (05) : 664 - 668
  • [5] Analysis on an improved Fourier transform profilometry
    Department of Opto-Electronics, Sichuan University, Chengdu 610064, China
    Zhongguo Jiguang, 2007, 1 (99-104):
  • [6] Fourier transform profilometry based on defocusing
    Fu, Yanjun
    Wu, Jianfeng
    Jiang, Guangyu
    OPTICS AND LASER TECHNOLOGY, 2012, 44 (04): : 727 - 733
  • [7] An Improved Circular Fringe Fourier Transform Profilometry
    Chen, Qili
    Han, Mengqi
    Wang, Ye
    Chen, Wenjing
    SENSORS, 2022, 22 (16)
  • [8] Fourier transform profilometry of tilted measurement system
    Xu Jian-Liang
    Wang Min
    Pan Hui
    Liu Xiao-Hui
    Qi Xiao-Li
    Xu Si-Xiang
    ACTA PHYSICA SINICA, 2011, 60 (07)
  • [9] A flexible calculation on improved Fourier transform profilometry
    Mao, Xianfu
    Su, Xianyu
    Chen, Wenjing
    Jin, Hailong
    OPTIK, 2010, 121 (22): : 2023 - 2027
  • [10] Error caused by sampling in Fourier transform profilometry
    Chen, WJ
    Yang, H
    Su, XY
    Tan, SX
    OPTICAL ENGINEERING, 1999, 38 (06) : 1029 - 1034