Oxygen on Everest: The development of modern open-circuit systems for mountaineers

被引:7
|
作者
Windsor, Jeremy S. [1 ]
Mcmorrow, Roger C. [1 ]
Rodway, George W. [1 ]
机构
[1] Inst Human Hlth & Performance, Ctr Altitude Space & Extreme Environm Med, London N19 5LW, England
来源
关键词
supplemental oxygen; Mt; Everest; hypoxia;
D O I
10.3357/ASEM.2329.2008
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The use of supplemental oxygen on Mt. Everest is now commonplace. From 1990 to 2006, more than 95% of those summiting the mountain did so using supplemental oxygen at some point during their ascent. The open circuit systems currently in use can be traced back to the device first used by George Finch on Mt. Everest in 1922. Wearing equipment weighing 33 lb (15 kg), Finch and his colleague Geoffrey Bruce set a world altitude record by reaching a height of 27,250 ft (8175 m). However, it would be with a lighter system weighing just 22 lb (10 kg) that Sir Edmund Hillary and Tenzing Norgay made the first ascent of the mountain in 1953. In the years since then considerable improvements in weight, comfort, and efficiency have been made; however, the original "open" principles first used by Finch almost a century ago still remain steadfastly in place.
引用
收藏
页码:799 / 804
页数:6
相关论文
共 50 条
  • [1] THE OPEN-CIRCUIT OXYGEN EQUIPMENT USED BY THE BRITISH MOUNT EVEREST EXPEDITION
    COTES, JE
    JOURNAL OF PHYSIOLOGY-LONDON, 1954, 123 (03): : P24 - P25
  • [2] Portable open-circuit spirometry systems
    Overstreet, Brittany S.
    Bassett, David R., Jr.
    Crouter, Scott E.
    Rider, Brain C.
    Parr, Brain B.
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2017, 57 (03): : 227 - 237
  • [3] OPEN-CIRCUIT REDUCTION OF OXYGEN COVERAGE ON IR BY HYDRAZINE
    URETAZANARTU, MS
    BOLETIN DE LA SOCIEDAD CHILENA DE QUIMICA, 1995, 40 (01): : 41 - 48
  • [4] Open-circuit voltage
    NASA Reference Publication, 1993, (1314): : 7 - 5
  • [5] EFFECTIVENESS OF OPEN-CIRCUIT AND OXYHOOD DELIVERY OF HELIUM-OXYGEN
    STILLWELL, PC
    QUICK, JD
    MUNRO, PR
    MALLORY, GB
    CHEST, 1989, 95 (06) : 1222 - 1224
  • [6] VALIDATION OF OPEN-CIRCUIT METHOD FOR DETERMINATION OF OXYGEN-CONSUMPTION
    WAGNER, JA
    HORVATH, SM
    DAHMS, TE
    REED, S
    JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (06) : 859 - 863
  • [7] Temporal development of open-circuit bright photovoltaic solitons
    张磊
    卢克清
    张美志
    刘雪明
    张彦鹏
    Chinese Physics B, 2008, 17 (07) : 2539 - 2543
  • [8] DETERMINATION OF OPEN-CIRCUIT SHEATH VOLTAGES OF CABLE SYSTEMS
    ADAMSON, C
    TAHA, EAZ
    WEDEPOHL, LM
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1968, 115 (08): : 1137 - &
  • [9] DEVELOPMENT OF A MOBILE, OPEN-CIRCUIT INDIRECT CALORIMETRY SYSTEM
    KELLY, JM
    KERRIGAN, B
    MILLIGAN, LP
    MCBRIDE, BW
    CANADIAN JOURNAL OF ANIMAL SCIENCE, 1994, 74 (01) : 65 - 71
  • [10] Temporal development of open-circuit bright photovoltaic solitons
    Zhang Lei
    Lu Ke-Qing
    Zhang Mei-Zhi
    Liu Xue-Ming
    Zhang Yan-Peng
    CHINESE PHYSICS B, 2008, 17 (07) : 2539 - 2543