A Three-Mask Process for Fabricating Vacuum-Sealed Capacitive Micromachined Ultrasonic Transducers Using Anodic Bonding

被引:69
|
作者
Yamaner, F. Yalcin [1 ]
Zhang, Xiao [1 ]
Oralkan, Omer [1 ]
机构
[1] N Carolina State Univ, Dept Elect & Comp Engn, Raleigh, NC 27695 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
SILICON-NITRIDE; GLASS; DESIGN; FILM;
D O I
10.1109/TUFFC.2014.006794
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper introduces a simplified fabrication method for vacuum-sealed capacitive micromachined ultrasonic transducer (CMUT) arrays using anodic bonding. Anodic bonding provides the established advantages of wafer-bonding-based CMUT fabrication processes, including process simplicity, control over plate thickness and properties, high fill factor, and ability to implement large vibrating cells. In addition to these, compared with fusion bonding, anodic bonding can be performed at lower processing temperatures, i.e., 350 degrees C as opposed to 1100 degrees C; surface roughness requirement for anodic bonding is more than 10 times more relaxed, i.e., 5-nm root-mean-square (RMS) roughness as opposed to 0.5 nm for fusion bonding; anodic bonding can be performed on smaller contact area and hence improves the fill factor for CMUTs. Although anodic bonding has been previously used for CMUT fabrication, a CMUT with a vacuum cavity could not have been achieved, mainly because gas is trapped inside the cavities during anodic bonding. In the approach we present in this paper, the vacuum cavity is achieved by opening a channel in the plate structure to evacuate the trapped gas and subsequently sealing this channel by conformal silicon nitride deposition in the vacuum environment. The plate structure of the fabricated CMUT consists of the single-crystal silicon device layer of a silicon-on-insulator wafer and a thin silicon nitride insulation layer. The presented fabrication approach employs only three photolithographic steps and combines the advantages of anodic bonding with the advantages of a patterned metal bottom electrode on an insulating substrate, specifically low parasitic series resistance and low parasitic shunt capacitance. In this paper, the developed fabrication scheme is described in detail, including process recipes. The fabricated transducers are characterized using electrical input impedance measurements in air and hydrophone measurements in immersion. A representative design is used to demonstrate immersion operation in conventional, collapse-snapback, and collapse modes. In collapse-mode operation, an output pressure of 1.67 MPapp is shown at 7 MHz on the surface of the transducer for 60-V-pp, 3-cycle sinusoidal excitation at 30-V dc bias.
引用
收藏
页码:972 / 982
页数:11
相关论文
共 15 条
  • [1] Fabrication of Vacuum-Sealed Capacitive Micromachined Ultrasonic Transducers With Through-Glass-Via Interconnects Using Anodic Bonding
    Zhang, Xiao
    Yamaner, Feysel Yalcin
    Oralkan, Omer
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2017, 26 (01) : 226 - 234
  • [2] Fabrication of Anodically Bonded Capacitive Micromachined Ultrasonic Transducers with Vacuum-Sealed Cavities
    Yamaner, F. Yalcin
    Zhang, Xiao
    Oralkan, Oemer
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 604 - 607
  • [3] Fabrication of Vacuum-Sealed Capacitive Micromachined Ultrasonic Transducer Arrays Using Glass Reflow Process
    Nguyen Van Toan
    Hahng, Shim
    Song, Yunheub
    Ono, Takahito
    MICROMACHINES, 2016, 7 (05):
  • [4] Anodic bonding using SOI wafer for fabrication of capacitive micromachined ultrasonic transducers
    Bellaredj, M.
    Bourbon, G.
    Walter, V.
    Le Moal, P.
    Berthillier, M.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2014, 24 (02)
  • [5] Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding technology
    Huang, YL
    Ergun, AS
    Hæggström, E
    Badi, MH
    Khuri-Yakub, BT
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (02) : 128 - 137
  • [6] Fabricating Capacitive Micromachined Ultrasonic Transducers with a Novel Silicon-Nitride-Based Wafer Bonding Process
    Logan, Andrew
    Yeow, John T. W.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (05) : 1074 - 1084
  • [7] Residual stress in capacitive micromachined ultrasonic transducers fabricated with Anodic Bonding using SOI wafer
    Walter, V.
    Bourbon, G.
    Le Moal, P.
    28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014), 2014, 87 : 883 - 886
  • [8] Fabricating capacitive micromachined ultrasonic transducers with direct wafer-bonding and locos technology
    Park, K. K.
    Lee, H. J.
    Kupnik, M.
    Oralkan, O.
    Khuri-Yakub, B. T.
    MEMS 2008: 21ST IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2008, : 339 - 342
  • [9] Fabrication of embossed capacitive micromachined ultrasonic transducers using sacrificial release process
    Yu, Yuanyu
    Wang, Jiujiang
    Pun, Sio Hang
    Cheng, Ching-Hsiang
    Lei, Kin Fong
    Vai, Mang, I
    Zhang, Shuang
    Mak, Peng Un
    IEICE ELECTRONICS EXPRESS, 2019, 16 (02):
  • [10] Fabrication of Capacitive Micromachined Ultrasonic Transducer Arrays With Isolation Trenches Using Anodic Wafer Bonding
    Mukhiya, Ravindra
    Aditi
    Prabakar, K.
    Raghuramaiah, M.
    Jayapandian, J.
    Gopal, Ram
    Khanna, Vinod Kumar
    Shekhar, Chandra
    IEEE SENSORS JOURNAL, 2015, 15 (09) : 5177 - 5184