Structural valve deterioration of a mitral Carpentier-Edwards pericardial bioprosthesis in an 87-year-old woman 16 years after its implantation

被引:0
|
作者
Ito, Hiroshi [1 ]
Sakata, Kensuke [1 ]
Haruki, Takashi [1 ]
Kobayashi, Yurio [1 ]
机构
[1] Saiseikai Shimonoseki Gen Hosp, Dept Cardiovasc Surg, Yamaguchi 7596603, Japan
来源
关键词
EXPERIENCE; SURGERY; PORCINE;
D O I
10.1186/1749-8090-6-88
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The second-generation pericardial valve, the Carpentier-Edwards perimount bioprosthetic (CEP) valve, shows dramatically improved durability as compared to the first-generation pericardial valve, and excellent performance has been obtained, in both the aortic and mitral positions. Especially in elderly patients with an implanted CEP valve, reoperation due to structural valve deterioration (SVD) is rarely required. Here, we report the case of an 87-year-old woman with an explanted CEP valve in the mitral position due to SVD, 16 years after its implantation.
引用
收藏
页数:3
相关论文
共 40 条
  • [1] Structural valve deterioration of a mitral Carpentier-Edwards pericardial bioprosthesis in an 87-year-old woman 16 years after its implantation
    Hiroshi Ito
    Kensuke Sakata
    Takashi Haruki
    Yurio Kobayashi
    Journal of Cardiothoracic Surgery, 6
  • [2] The case of an explanted 16-year-old mitral Carpentier-Edwards pericardial bioprosthesis
    Murayama H.
    Watanabe T.
    Yano T.
    Kida N.
    Hatano Y.
    Ohara K.
    Kobayashi A.
    Journal of Artificial Organs, 2006, 9 (4) : 259 - 262
  • [3] Structural valve deterioration of a Carpentier-Edwards aortic pericardial bioprosthesis in a 68-year-old male patient
    Sakamoto, Yoshimasa
    Yoshitake, Michio
    Matsumura, Yoko
    Murayama, Fumiaki
    Hashimoto, Kazuhiro
    CHIRURGIA-ITALY, 2018, 31 (02): : 67 - 69
  • [4] A case of Carpentier-Edwards pericardial bioprosthesis in mitral position explanted 22 years after implantation
    Kubota, Suguru
    Wakasa, Satoru
    Ooka, Tomonori
    Tachibana, Tsuyoshi
    Shiiya, Norihiko
    Matsui, Yoshiro
    JOURNAL OF ARTIFICIAL ORGANS, 2010, 13 (01) : 48 - 50
  • [5] Pannus overgrowth after mitral valve replacement with a Carpentier-Edwards pericardial bioprosthesis
    Oda, Takeshi
    Kato, Seiya
    Tayama, Eiki
    Fukunaga, Shrii
    Akashi, Hidetoshi
    Aoyagi, Shigeaki
    JOURNAL OF ARTIFICIAL ORGANS, 2009, 12 (01) : 55 - 57
  • [6] Pannus overgrowth after mitral valve replacement with a Carpentier-Edwards pericardial bioprosthesis
    Takeshi Oda
    Seiya Kato
    Eiki Tayama
    Shuji Fukunaga
    Hidetoshi Akashi
    Shigeaki Aoyagi
    Journal of Artificial Organs, 2009, 12 : 55 - 57
  • [7] Carpentier-Edwards pericardial bioprosthesis at the mitral site: Twelve year results
    Goldsmith, I
    Lip, GYH
    Patel, RL
    Norton, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 399A - 399A
  • [8] Immediate structural valve deterioration of 27-mm Carpentier-Edwards aortic pericardial bioprosthesis
    Fleisher, AG
    Lafaro, RJ
    Moggio, RA
    ANNALS OF THORACIC SURGERY, 2004, 77 (04): : 1443 - 1445
  • [9] Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results
    Murakami, T
    Eishi, K
    Nakano, S
    Kobayashi, J
    Sasako, Y
    Isobe, F
    Kosakai, Y
    Kito, Y
    Kawashima, Y
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 (01): : 45 - 49
  • [10] Leaflet detachment in a Carpentier-Edwards Perimount Magna mitral pericardial valve bioprosthesis
    Elena Arnaiz-Garcia, Maria
    Maria Gonzalez-Santos, Jose
    Iscar-Galan, Alberto
    Javier Lopez-Rodriguez, Francisco
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (06) : 1293 - 1293