An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery

被引:15
|
作者
Capaldi, Dante P., I [1 ]
Skinner, Lawrie B. [1 ]
Dubrowski, Piotr [1 ]
Yu, Amy S. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 11期
关键词
3D printing; QA; stereotactic radiosurgery; frameless brain SRS treatment; off-axis Winston-Lutz; single-isocenter multitarget SRS; BODY RADIATION-THERAPY; LINEAR-ACCELERATOR; PRACTICE GUIDELINE; FILM DOSIMETRY; TECHNICAL NOTE; ACCURACY; BRAIN; QA;
D O I
10.1088/1361-6560/ab8534
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Brain stereotactic radiosurgery (SRS) treatments require multiple quality assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear accelerator is crucial. In this study, a novel brain SRS integrated phantom was developed and validated to enable SRS QA with a single phantom to facilitate implementation of a frameless single-isocenter, multitarget SRS program. This phantom combines the independent verification of each positioning system, the Winston-Lutz, off-axis accuracy evaluation (i.e. off-axis Winston-Lutz), and the dosimetric accuracy utilizing both point dose measurements as well as film measurement, without moving the phantom. A novel 3D printed phantom, coined OneIso, was designed with a movable insert which can switch between the Winston-Lutz test target and dose measurement without moving the phantom itself. For dose verification, ten brain SRS clinical treatment plans with 10 MV flattening-filter-free beams were delivered on a Varian TrueBeam with a high-definition multileaf collimator (HD-MLC). Radiochromic film and pinpoint ion chamber comparison measurements were made between the OneIso and solid water (SW) phantom setups. For the off-axis Winston-Lutz measurements, a row of off-axis ball bearings (BBs) was integrated into the OneIso. To quantify the spatial accuracy versus distance from the isocenter, two-dimensional displacements were calculated between the planned and delivered BB locations relative to their respective MLC defined field border. OneIso and the SW phantoms agree within 1%, for both film and point dose measurements. OneIso identified a reduction in spatial accuracy further away from the isocenter. Differences increased as distance from the isocenter increased, exceeding recommended SRS accuracy tolerances at 7 cm away from the isocenter. OneIso provides a streamlined, single-setup workflow for single-isocenter multitarget frameless linac-based SRS QA. Additionally, with the ability to quantify off-axis spatial discrepancies, we can determine limitations on the maximum distance between targets to ensure a single-isocenter multitarget SRS program meets recommended guidelines.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] An Integrated Quality Assurance Phantom for Frameless Single-Isocenter Multitarget Stereotactic Radiosurgery: A Multi-Institutional Trial
    Capaldi, D.
    Nano, T.
    Skinner, L.
    Chuang, C.
    Dubrowski, P.
    Xing, L.
    Yu, A.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E386 - E387
  • [2] Evaluation of Off-Axis Spatial Accuracy Using An Integrated Quality Assurance Phantom for Frameless Single-Isocenter Multitarget Stereotactic Radiosurgery
    Capaldi, D.
    Skinner, L.
    Dubrowski, P.
    Yu, A.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E412 - E412
  • [3] Effective Control of Brain Metastases Irrespective of Distance from Isocenter in Single-isocenter Multitarget Stereotactic Radiosurgery
    Aoki, Ken
    Nagatani, Yukihiro
    Noma, Kazuo
    Tsugawa, Takuya
    Kono, Naoaki
    Kida, Yukako
    Harada, Naoki
    Tanoue, Yoshihide
    Watanabe, Yoshiyuki
    [J]. ANTICANCER RESEARCH, 2021, 41 (05) : 2575 - 2581
  • [4] Single-Isocenter Multitarget Stereotactic Radiosurgery Is Safe and Effective in the Treatment of Multiple Brain Metastases
    Palmer, Joshua D.
    Sebastian, Nikhil T.
    Chu, Jacquline
    DiCostanzo, Dominic
    Bell, Erica H.
    Grecula, John
    Arnett, Andrea
    Blakaj, Dukagjin M.
    McGregor, John
    Elder, James B.
    Lu, Lanchun
    Zoller, Wesley
    Addington, Mark
    Lonser, Russell
    Chakravarti, Arnab
    Brown, Paul D.
    Raval, Raju
    [J]. ADVANCES IN RADIATION ONCOLOGY, 2020, 5 (01) : 70 - 76
  • [5] Single-Isocenter Multitarget Stereotactic Radiosurgery is Safe and Effective in the Treatment of Multiple Brain Metastases
    Sebastian, N.
    Raval, R.
    Chu, J.
    DiCostanzo, D. J.
    Bell, E. H.
    Grecula, J. C.
    Arnett, A. L. H.
    Blakaj, D. M.
    McGregor, J.
    Elder, J. B.
    Lonser, R. R.
    Chakravarti, A.
    Brown, P. D.
    Palmer, J. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E89 - E89
  • [6] Frameless single-isocenter intensity modulated stereotactic radiosurgery for simultaneous treatment of multiple intracranial metastases
    Lau, Steven K. M.
    Zhao, Xiao
    Carmona, Ruben
    Knipprath, Erik
    Simpson, Daniel R.
    Nath, Sameer K.
    Kim, Gwe-Ya
    Hattangadi, Jona A.
    Chen, Clark C.
    Murphy, Kevin T.
    [J]. TRANSLATIONAL CANCER RESEARCH, 2014, 3 (04) : 383 - 390
  • [7] Development of a Phantom to Verify Targeting Accuracy of Single-Isocenter Multiple Lesion Stereotactic Radiosurgery
    Murray, A.
    Kudrolli, H.
    Tirpak, L.
    Simon, T.
    Mishra, V.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E144 - E144
  • [8] The spatial accuracy of two frameless, linear accelerator-based systems for single-isocenter, multitarget cranial radiosurgery
    Ezzell, Gary A.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (02): : 37 - 43
  • [9] Quality Assurance Study of Stereotactic Radiosurgery of Multiple Brain Lesions with a Single Isocenter
    Zhang, J.
    Rahimian, J.
    Lee, S.
    Lien, W.
    Han, J.
    Kim, D.
    Goldman, K.
    Lu, S.
    Hong, G.
    Qian, Y.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E326 - E326
  • [10] Single-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Multiple Intracranial Metastases
    Lau, Steven K. M.
    Zakeri, Kaveh
    Zhao, Xiao
    Carmona, Ruben
    Knipprath, Erik
    Simpson, Daniel R.
    Nath, Sameer K.
    Kim, Gwe-Ya
    Sanghvi, Parag
    Hattangadi-Gluth, Jona A.
    Chen, Clark C.
    Murphy, Kevin T.
    [J]. NEUROSURGERY, 2015, 77 (02) : 233 - 240