Electron transfer dissociation in the hexapole collision cell of a hybrid quadrupole-hexapole Fourier transform ion cyclotron resonance mass spectrometer

被引:47
|
作者
Kaplan, Desmond A. [1 ]
Hartmer, Ralf [2 ]
Speir, J. Paul [1 ]
Stoermer, Carsten [2 ]
Gumerov, Dmitry [1 ]
Easterling, Michael L. [1 ]
Brekenfeld, Andreas [2 ]
Kim, Taeman [1 ]
Laukien, Frank [1 ]
Park, Melvin A. [1 ]
机构
[1] Bruker Daltonics Inc, Billerica, MA 01821 USA
[2] Bruker Daltonik GmbH, D-28359 Bremen, Germany
关键词
D O I
10.1002/rcm.3356
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electron transfer dissociation (ETD) of proteins is demonstrated in a hybrid quadrupole-hexapole Fourier transform ion cyclotron resonance mass spectrometer (Qh-FTICRMS). Analyte ions are selected in the mass analyzing quadrupole, accumulated in the hexapole linear ion trap, reacted with fluoranthene reagent anions, and then analyzed via an FTICR mass analyzer. The hexapole trap allows for a broad fragment ion mass range and a high ion storage capacity. Using a 3 T FTICRMS, resolutions of 60000 were achieved with mass accuracies averaging below 1.4ppm. The high resolution, high mass accuracy ETD spectra provided by FTICR obviates the need for proton transfer reaction (PTR) charge state reduction of ETD product ions when analyzing proteins or large peptides. This is demonstrated with the ETD of ubiquitin and apomyoglobin yielding sequence coverages of 37 and 20%, respectively. We believe this represents the first reported successful combination of ETD and a FTICRMS. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [1] Optimization of Parameters of Hexapole Magnets for Electron Cyclotron Resonance Ion Sources
    Pugachev, D. K.
    Bogomolov, S. L.
    Bondarchenko, A. E.
    Berestov, K. I.
    Kuzmenkov, K. I.
    Efremov, A. A.
    Loginov, V. N.
    Mironov, V. E.
    Protasov, A. A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2024, 21 (03) : 331 - 336
  • [2] Surface-Induced Dissociation of Protein Complexes in a Hybrid Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
    Yan, Jing
    Zhou, Mowei
    Gilbert, Joshua D.
    Wolff, Jeremy J.
    Somogyi, Arpad
    Pedder, Randall E.
    Quintyn, Royston S.
    Morrison, Lindsay J.
    Easterling, Michael L.
    Pasa-Tolic, Ljiljana
    Wysocki, Vicki H.
    ANALYTICAL CHEMISTRY, 2017, 89 (01) : 895 - 901
  • [3] Electron capture dissociation of polypeptides using a 3 Tesla Fourier transform ion cyclotron resonance mass spectrometer
    Polfer, NC
    Haselmann, KF
    Zubarev, RA
    Langridge-Smith, PRR
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (10) : 936 - 943
  • [4] Design for an 18 GHz Open Hexapole Electron Cyclotron Resonance Ion Source
    Vondrasek, R. C.
    McLain, J.
    Scott, R. H.
    20TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2024, 2743
  • [5] Electron capture dissociation of substance P using a commercially available Fourier transform ion cyclotron resonance mass spectrometer
    Axelsson, J
    Palmblad, M
    Håkansson, K
    Håkansson, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (06) : 474 - 477
  • [6] A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers in fourier transform ion cyclotron resonance mass spectrometry
    Hannis, JC
    Muddiman, DC
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (10) : 876 - 883
  • [7] Ion discrimination during ion accumulation in a quadrupole interface external to a Fourier transform ion cyclotron resonance mass spectrometer
    Belov, ME
    Nikolaev, EN
    Harkewicz, R
    Masselon, CD
    Alving, K
    Smith, RD
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) : 205 - 225
  • [8] A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers in fourier transform ion cyclotron resonance mass spectrometry
    Hannis, James C
    Muddiman, David C
    2000, Elsevier Inc. (11)
  • [9] Construction of a hybrid quadrupole/Fourier Transform Ion Cyclotron Resonance Mass Spectrometer for versatile MS/MS above 10 kDa
    Patrie, SM
    Charlebois, JP
    Whipple, D
    Kelleher, NL
    Hendrickson, CL
    Quinn, JP
    Marshall, AG
    Mukhopadhyay, B
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (07) : 1099 - 1108
  • [10] Quadrupole mass filters, quadrupole ion traps and Fourier transform ion cyclotron resonance spectrometers
    Olimpieri, L
    Traldi, P