Dry eye and blink rate simulation with a pig eye model

被引:12
|
作者
Choy, Emily Pik Yin [1 ]
Cho, Pauline [1 ]
Benzie, Iris Frances Forster [2 ]
Choy, Camus Kar Man [1 ]
机构
[1] Hong Kong Polytech Univ, Sch Optometry, Kowloon, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
关键词
dry eye model; desiccation-induced; blink rate; porcine; Trypan blue;
D O I
10.1097/OPX.0b013e31816225ed
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To simulate medium level "dry eye" and investigate the effect of "blink" rates in "dry eye" condition using a novel porcine dry eye model (pDEM). Methods. In the first experiment, a 40 s "lacrimation/blink" interval (lacrimation occurring in conjunction with blink) was set in the pDEM to simulate a medium level of "dry eye" condition. In the second experiment, "lacrimation" interval was set at 60 s and three different "inter-blink" intervals of 6, 12, and 20 s were set in groups A, B, and C, respectively. The integrity of each cornea was assessed before and after experiments by slit-lamp microscopy with sodium fluorescein solution. The viability of corneal epithelial cells was assessed by the Trypan blue exclusion test after the experiment. Results. The amount of sodium fluorescein staining was significantly (p < 0.05) lower at the end of the experiment, when the "inter-blink" interval was set at 12 s. The medians of the final fluorescein grades of corneas in the pDEM were grade 1.5, 1.0, and 2.0 when the "inter-blink" intervals were set at 6, 12, and 20 s, respectively. There was no significant difference in the number of damaged cells between the central and peripheral corneas with different "inter-blink" intervals. Although in each.case the peripheral area had a lower number of non-viable cells than the central area of the cornea, there was no significant change in the number of Trypan blue stained cells in either area with different "inter-blink" intervals. Conclusion. Different severity levels of "dry eye" can be simulated using the newly developed pDEM. Increased blink rate may protect the cornea against desiccation-induced damage; however, increased blink rate may also increase shear force between the cornea and conjunctiva and result in mechanical damage because of increased frictional force.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [1] BLINK RATE AND THE DRY EYE CONDITION
    NAKAMORI, K
    NAKAJIMA, T
    ODAWARA, M
    KOYAMA, I
    NEMOTO, M
    TSUBOTA, K
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1288 - 1288
  • [2] Blink Patterns in Normal and Dry Eye Subjects; Beyond Blink Rate
    White, R.
    Rodriguez, J.
    Lane, K. J.
    Johnston, P.
    Angjeli, E.
    Abelson, M. B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] An Eye Blink Detection System for Dry Eye Syndrome and Its Performance Model
    Govardhane, Prathamesh
    Wyawahare, Medha
    AMBIENT COMMUNICATIONS AND COMPUTER SYSTEMS, RACCCS 2017, 2018, 696 : 475 - 484
  • [4] Evaluation of Partial Blink Rate as a Measurement of Dry Eye Disease
    Sella, Ruti
    Jie, Ying
    Feng, Jun
    Gomez, Laura M.
    Afshari, Natalie A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [5] PROSE used to Reduce Blink Rate in Dry Eye and Blepharospasm
    Hemmati, Roxana Tahirih
    Yen, Michael Tze-Chien
    Pflugfelder, Stephen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [6] ''Blink oscillations'' associated with dry eye
    Evinger, C
    Peshori, KR
    Sibony, PA
    Wittpenn, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 574 - 574
  • [7] Spontaneous Eye Blink Patterns in Dry Eye: Clinical Correlations
    Su, Yuandong
    Liang, Qingfeng
    Su, Guanyu
    Wang, Ningli
    Baudouin, Christophe
    Labbe, Antoine
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (12) : 5149 - 5156
  • [8] Menisci and fullness of the blink in dry eye
    Harrison, Wendy W.
    Begley, Carolyn G.
    Liu, Haixia
    Chen, Minhua
    Garcia, Michelle
    Smith, Janine A.
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (08) : 706 - 714
  • [9] A correlation between blink rate and corneal sensitivity in a dry eye population
    Nally, L
    Ousler, GW
    Emory, TB
    Abelson, MB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U433 - U433
  • [10] Effect of an adverse environment on blink rate in a population of dry eye patients
    Casavani, J
    Ousler, GW
    Abelson, MB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U120 - U120