Measurement method of Stokes parameters using a quarter-wave plate with phase difference errors

被引:17
|
作者
Kihara, Toshiki [1 ]
机构
[1] Kinki Univ, Sch Sci & Engn, Higashiosaka, Osaka 5778502, Japan
关键词
LIGHT;
D O I
10.1364/AO.50.002582
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The Stokes parameters (S-0, S-1, S-2, and S-3) of monochromatic light can be measured using the adjustable azimuth settings of a quarter-wave plate and a polarizer. When measuring the Stokes parameters of light of an arbitrary wavelength, the measurement of S-3 is affected by the phase difference error Delta q(lambda i), due to the mismatch with respect to wavelength with the quarter-wave plate. In this method, Delta q(lambda i), due to such a mismatch of incident light of arbitrary wavelength, can be overcome by a judicious choice of azimuth settings of the quarter-wave plate and the use of a polarizer; however, the use of a precision quarter-wave plate is necessary. The present paper proposes a measurement method of Stokes parameters of incident light of arbitrary wavelength using a quarter-wave plate with phase difference errors. (C) 2011 Optical Society of America
引用
收藏
页码:2582 / 2587
页数:6
相关论文
共 50 条
  • [1] Measurement of Stokes parameters by quarter-wave plate and polarizer
    Kihara, T.
    Advances in Experimental Mechanics IV, 2005, 3-4 : 235 - 240
  • [2] Method for reducing the influence of quarter-wave plate errors in phase stepping photoelasticity
    Universita degli Studi di Palermo, Italy
    J Strain Anal Eng Des, 3 (207-216):
  • [3] A method for reducing the influence of quarter-wave plate errors in phase stepping photoelasticity
    Ajovalasit, A
    Barone, S
    Petrucci, G
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 1998, 33 (03): : 207 - 216
  • [4] Stokes parameters measurement system designed by symmetric division of amplitude with double quarter-wave plate
    Ma, Xirui
    Zhao, Hu
    Zeng, Yazheng
    Gao, Siqi
    Cheng, Jiyuan
    He, Qiangqiang
    Mao, Jiandong
    Zhou, Chunyan
    Xin, Gong
    Rao, Zhimin
    OPTICS COMMUNICATIONS, 2023, 549
  • [5] New method for retardance measurement of a quarter-wave plate
    Tan Q.
    Xu Q.
    Xie N.
    1600, Chinese Society of Astronautics (45):
  • [6] Novel method for measurement of retardance of a quarter-wave plate
    Wang, ZP
    Li, QB
    Tan, Q
    Huang, ZJ
    Shi, JH
    OPTICS AND LASER TECHNOLOGY, 2004, 36 (04): : 285 - 290
  • [7] OPTICAL HETERODYNE MEASUREMENT OF THE PHASE RETARDATION OF A QUARTER-WAVE PLATE
    YAO, L
    ZHOU, ZY
    WANG, RW
    OPTICS LETTERS, 1988, 13 (07) : 553 - 555
  • [8] Error analysis and Stokes parameter measurement of rotating quarter-wave plate polarimeter
    Zhi, Dan-Dan
    Li, Jian-Jun
    Gao, Dong-Yang
    Zhai, Wen-Chao
    Huang, Xiong-Hao
    Zheng, Xiao-Bing
    CHINESE PHYSICS B, 2017, 26 (12)
  • [9] Error analysis and Stokes parameter measurement of rotating quarter-wave plate polarimeter
    支丹丹
    李健军
    高冬阳
    翟文超
    黄雄豪
    郑小兵
    Chinese Physics B, 2017, 26 (12) : 246 - 251
  • [10] Measurement of the delay of the quarter-wave plate by phase-modulated ellipsometry
    Institute of Laser Research, Qufu Normal University, Qufu 273165, China
    不详
    Guangxue Xuebao, 2006, 3 (379-382):