Skeletal troponin I cross-reactivity in different cardiac troponin I assay versions

被引:13
|
作者
Hyytia, Heidi [1 ]
Heikkila, Taina [1 ]
Hedberg, Pirjo [2 ,3 ]
Puolakanaho, Tarja [2 ,3 ]
Pettersson, Kim [1 ]
机构
[1] Univ Turku, Dept Biotechnol, FIN-20520 Turku, Finland
[2] Oulu Univ Hosp, NordLab Oulu, Oulu, Finland
[3] Univ Oulu, Dept Clin Chem, Oulu, Finland
关键词
Troponin I; Immunoassay; Cross-reactivity; HIGH-SENSITIVITY TROPONIN; IMMUNOASSAY; SPECIFICITY; DIAGNOSIS; SERUM; FRAGMENTS; MUSCLE;
D O I
10.1016/j.clinbiochem.2014.12.028
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To study the skeletal troponin I (skTnI) cross-reactivity of four different commercially available antibodies in four cardiac troponin I (cTnI) research assay versions having the same epitope specificity as evidenced by peptide mapping. Design and methods: The four research assays all use two solid phase antibodies and one detection antibody attached to intrinsically fluorescent nanoparticles.Two alternative antibodies were used for one capture antibody and two for the detector antibody. The assays were evaluated in terms of analytical sensitivity and by determining assay cross-reactivity to skTnI. Additionally, regression analysis was performed by measuring a sample panel (n = 101) with all of the four assay versions. Results: A false positive cTnI concentration of >7000 ng/L was measured with one of the assay versions, when serum was spiked with 500,000 ng/L skTnI. The corresponding observed cTnI values for the other three assay versions varied from 616 ng/L to 727 ng/L. Out of the 101 clinical samples assayed, five showed spuriously (3- to 148 fold) elevated cTnI values with the skTnI interference prone assay setup, but not with the other assay versions. According to our investigational skTnI assay, all five samples contained measurable amounts of skTnI (range: 5500-702,000 ng/L). Conclusions: Two out of four cTnI antibodies tested cross-reacted vastly with skTnI but did not cause any notable interference unless paired together. Therefore, skTnI cross reactivity should be carefully assessed when cTnI assay antibodies claimed to be cTnI specific are selected. (C) 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 50 条
  • [41] Myocardial fixation of anticardiac troponin I antibody and cardiac troponin I release
    Alwan, K
    Chocron, S
    Mourand, JL
    Toubin, G
    Gauchez, P
    Kantelip, B
    Kantelip, JP
    Etievent, JP
    JOURNAL OF CARDIOVASCULAR SURGERY, 2000, 41 (04): : 541 - 545
  • [42] Effect of denervation on the content of cardiac troponin-T and cardiac troponin-I in rat skeletal muscle
    Fredericks, Salim
    Degens, Hans
    McKoy, Godfrina
    Bainbridge, Katie
    Collinson, Paul O.
    Coulton, Gary
    Elmahdi, Habab
    Holt, David W.
    CLINICAL BIOCHEMISTRY, 2007, 40 (5-6) : 423 - 426
  • [43] Reply: The complementary role of cardiac troponin I and cardiac troponin T
    Tveit, Sjur H.
    Myhre, Peder L.
    Rosjo, Helge
    Omland, Torbjorn
    CLINICAL BIOCHEMISTRY, 2020, 78 : 42 - 42
  • [44] Cardiac troponin T on Elecsys 2010: comparison with cardiac troponin I
    Cauliez, B
    Hue, G
    Lavoinne, A
    ANNALES DE BIOLOGIE CLINIQUE, 1998, 56 (06) : 711 - 715
  • [45] Interaction of cardiac troponin C and troponin I with W7 in the presence of three functional regions of cardiac troponin I
    Li, Monica X.
    Hoffman, Ryan M. B.
    Sykes, Brian D.
    BIOCHEMISTRY, 2006, 45 (32) : 9833 - 9840
  • [46] Sensitizing cardiac troponin to calcium through troponin I.
    Tikunova, Svetlana B.
    Swartz, Darl R.
    Davis, Jonathan P.
    BIOPHYSICAL JOURNAL, 2007, : 629A - 629A
  • [47] Interaction of bepridil with the cardiac troponin C/troponin I complex
    Abusamhadneh, E
    Abbott, MB
    Dvoretsky, A
    Finley, N
    Sasi, S
    Rosevear, PR
    FEBS LETTERS, 2001, 506 (01) : 51 - 54
  • [48] Diagnosis of myocardial infarction: Cardiac troponin I or troponin T?
    Lee, Kuan Ken
    Shah, Anoop S. V.
    Mills, Nicholas L.
    CLINICAL BIOCHEMISTRY, 2014, 47 (06) : 319 - 320
  • [49] Discrepant results for cardiac troponin T and troponin I in chronic myopathy, depending on instrument and assay generation
    Braun, SL
    Pongratz, DE
    Bialk, P
    Liem, S
    Schlotter, B
    Vogt, W
    CLINICAL CHEMISTRY, 1996, 42 (12) : 2039 - 2041
  • [50] Structure of skeletal troponin-C in complex with skeletal troponin-Ins-m:: Comparison to cardiac troponin-C-troponin-I147-163 complex.
    Spyracopoulos, L
    McKay, RT
    Sykes, BD
    BIOPHYSICAL JOURNAL, 2000, 78 (01) : 434A - 434A