Medical X-ray tube

被引:0
|
作者
Taubin, M. [1 ]
Yaskolko, A. [1 ]
机构
[1] FSUE SRI SIA Lutch, Podolsk, Russia
关键词
X-ray; tube; monocrystalline; cathode; anod;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray tube test data are shown in this paper and proposals of cerametallic X-ray tube properties improving are made. Particularly, advantages of using monocrystalline anode and monocrystalline flat emitter are presented. During first 1000 cycles dosage rate of X-ray tube with monocrystalline anode reducing for (10+12)%. Then dose reducing rate become stable near (0,7+1,0)% per 1000 cycles. X-ray tube with polyocrystalline anode has more significant reducing during first 4000 cycles. Modern mammography X-ray tubes require small electron focal spot. Traditional coil emitter made of tungsten filament dont satisfy this requirements. Thus most perspective emitter for mammography X-ray tubes is emitter with plane emitting surface. In addition tungsten emitter with single-crystal structure has less working temperature due to its smaller work function ([111] crystallographic plane of tungsten has work function about 4,4 eV, while polycrystalline tungsten - 4,55 eV). Working temperature difference of this materials is about 70 degrees C.
引用
收藏
页码:722 / 724
页数:3
相关论文
共 50 条
  • [1] Improvement of Medical X-Ray Tube Performance
    Taubin M.L.
    Yaskolko A.A.
    Biomedical Engineering, 2010, 44 (2) : 73 - 75
  • [2] X-Ray tube cathodes of medical purpose
    Taubin M.L.
    Platonov V.F.
    Yaskolko A.A.
    Biomedical Engineering, 2009, 43 (1) : 48 - 50
  • [3] X-ray tube
    Kravetz, RE
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2001, 96 (04): : 1273 - 1273
  • [4] Development of X-Ray Talbot-Lau Interferometer with a Practical X-Ray Tube for Medical Imaging
    Makifuchi, Chiho
    Kido, Kazuhiro
    Kiyohara, Junko
    Ito, Tsukasa
    Nagatsuka, Sumiya
    Momose, Atsushi
    INTERNATIONAL CONFERENCE ON ADVANCED PHASE MEASUREMENT METHODS IN OPTICS AN IMAGING, 2010, 1236 : 203 - +
  • [5] A miniature x-ray tube
    Haga, A
    Senda, S
    Sakai, Y
    Mizuta, Y
    Kita, S
    Okuyama, F
    APPLIED PHYSICS LETTERS, 2004, 84 (12) : 2208 - 2210
  • [6] The Coolidge X-ray tube
    不详
    NATURE, 1917, 99 : 295 - 295
  • [7] COOLIDGE X-RAY TUBE
    WALTHER, KM
    RONTGEN-BLATTER KLINIK UND PRAXIS, 1974, 27 (07): : 375 - 377
  • [8] X-Ray Tube to YouTube
    Coblentz, Craig L.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2008, 59 (04): : 172 - 173
  • [9] SMALL X-RAY TUBE
    MARCLEY, RG
    AMERICAN JOURNAL OF PHYSICS, 1961, 29 (07) : 445 - &
  • [10] X-ray Tube with a Photocathode
    Potrakhov, Nikolay N.
    Lukyanov, Valery N.
    2014 TENTH INTERNATIONAL VACUUM ELECTRON SOURCES CONFERENCE (IVESC), 2014,