On-line spectrophotometric determination of ferrous and total iron in monominerals by flow injection combined with a Schlenk line-based digestion apparatus to exclude oxygen

被引:6
|
作者
Xue, Ding-Shuai [1 ,2 ,3 ]
Chen, Guo-Ju [4 ]
Su, Ben-Xun [1 ]
Liu, Yan-Hong [1 ]
Zhang, Dan-Ping [1 ]
Guo, Qian [1 ]
Guo, Ju-Jie [1 ]
Sun, Jie-Fang [5 ]
机构
[1] Chinese Acad Sci, Inst Geol & Geophys, Key Lab Mineral Resources, POB 9825, Beijing 100029, Peoples R China
[2] Chinese Acad Sci, Innovat Acad Earth Sci, Beijing 100029, Peoples R China
[3] Univ Chinese Acad Sci, Coll Earth & Planetary Sci, Beijing, Peoples R China
[4] State Key Lab Comprehens Utilizat Nickel & Cobalt, Jinchang 737100, Gansu, Peoples R China
[5] Beijing Ctr Dis Prevent & Control, Beijing Key Lab Diagnost & Traceabil Technol Food, Beijing 100013, Peoples R China
基金
中国国家自然科学基金;
关键词
On-line photochemical method; Ferrous iron; Total iron; Monomineral; Flow injection; Schlenk line; SILICATE ROCKS; TRACE-ELEMENTS; FERRIC IRON; FE(II); SPECIATION; SOILS; 1,10-PHENANTHROLINE; EXTRACTION; MINERALS;
D O I
10.1016/j.microc.2020.104743
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line photochemical method for measuring the ferrous iron [Fe(II)] and total iron [Fe(T)] contents in monominerals is described herein. A special digestion apparatus connected with a Schlenk line was designed to exclude oxygen during sample digestion. Subsequently, a spectrophotometric flow injection analysis (FIA) system was employed to automate the determination. As a result, a facile, reliable, and accurate analytical procedure was obtained, and both the sample and reagent consumption were reduced compared with traditional spectrophotometric procedures. In addition, the concentrations of the reductant and the chromogenic agent were optimized along with the sample leaching conditions (e.g., the amounts of H2SO4 and HF). Furthermore, the method precision was assessed by comparing the obtained results with those of four geological reference materials (relative standard deviation (RSD) for Fe(II) <2.30%, RSD for Fe(T) <1.75%). Finally, the accuracy of the method was assessed for four monomineral samples using the standard addition method, with recovery percentages of 95.74-104.69% and 95.07-104.56% being obtained for Fe(II) and Fe(T), respectively.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] An Improved Procedure for the Determination of Ferrous Iron Mass Fraction in Silicate Rocks Using a Schlenk Line-Based Digestion Apparatus to Exclude Oxygen
    Xue, Dingshuai
    Wang, Hongyue
    Liu, Yanhong
    Xie, Liewen
    Shen, Ping
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2017, 41 (03) : 411 - 425
  • [2] Spectrophotometric flow injection determination of total phosphorus in beer using on-line UV/thermal induced digestion
    S. M. V. Fernandes
    J. L. F. C. Lima
    A. O. S. S. Rangel
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 112 - 115
  • [3] Spectrophotometric flow injection determination of total phosphorus in beer using on-line UV/thermal induced digestion
    Fernandes, SMV
    Lima, JLFC
    Rangel, AOSS
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (01): : 112 - 115
  • [4] Spectrophotometric determination of urinary iodine by flow injection analysis with on-line catalytic digestion
    Zhang, YP
    Yuan, DX
    Chen, JX
    Lan, TS
    Chen, HQ
    CLINICAL CHEMISTRY, 1996, 42 (12) : 2021 - 2027
  • [5] Kinetic Spectrophotometric Determination of Total Iron in Natural Water by Flow Injection Analysis Using On-Line Preconcentration
    Suling Feng
    Zhijun Guo
    Jing Fan
    Xingguo Chen
    Junying Sun
    Microchimica Acta, 2005, 149 : 61 - 65
  • [6] Kinetic spectrophotometric determination of total iron in natural water by flow injection analysis using on-line preconcentration
    Feng, SL
    Guo, ZJ
    Fan, J
    Chen, XG
    Sun, JY
    MICROCHIMICA ACTA, 2005, 149 (1-2) : 61 - 65
  • [7] Determination of total and inorganic mercury in whole blood by on-line digestion with flow injection
    Chen, HP
    Paschal, DC
    Miller, DT
    Morrow, JC
    ATOMIC SPECTROSCOPY, 1998, 19 (05) : 176 - 179
  • [8] Determination of iron(II) and total iron using flow injection on-line preconcentration with FAAS
    Xu, GM
    Ye, YX
    Yin, XF
    Shen, H
    Ali, A
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2000, 21 (03): : 350 - 353
  • [9] Determination of Iron( II ) and Total Iron Using Flow Injection On-line Preconcentration with FAAS
    Xu, Guang-Ming
    Ye, Ying-Xue
    Yin, Xue-Feng
    Shen, Hong
    Ali, Akbar
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 2000, 21 (03): : 352 - 353
  • [10] Total nitrogen determination by flow injection using on-line microwave-assisted digestion
    Cerda, A
    Oms, MT
    Forteza, R
    Cerda, V
    ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) : 273 - 279