Direct sample introduction of wines in graphite furnace atomic absorption spectrometry for the simultaneous determination of arsenic, cadmium, copper and lead content

被引:91
|
作者
Ajtony, Zsolt [1 ]
Szoboszlai, Norbert [2 ]
Susko, Emoke Klaudia [1 ]
Mezei, Pal [3 ]
Gyoergy, Krisztina [3 ]
Bencs, Laszlo [3 ]
机构
[1] Univ W Hungary, Inst Food Sci, H-9200 Mosonmagyarovar, Hungary
[2] Eotvos Lorand Univ, Dept Inorgan & Analyt Chem, Inst Chem, H-1518 Budapest, Hungary
[3] Hungarian Acad Sci, Res Inst Solid State Phys & Opt, H-1525 Budapest, Hungary
基金
匈牙利科学研究基金会;
关键词
wine; mineral content; electrothermal atomic absorption spectrometry; ETAAS; SIMAA; 6000; high sugar content; hierarchical cluster analysis; alcoholic beverage;
D O I
10.1016/j.talanta.2008.04.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multi-element graphite furnace atomic absorption spectrometry (GFAAS) method was elaborated for the simultaneous determination of As, Cd, Cu, and Ph in wine samples of various sugar contents using the transversally heated graphite atomizer (THGA) with end-capped tubes and integrated graphite platforms (IGPs). For comparative GFAAS analyses, direct injection (i.e., dispensing the sample onto the IGP) and digestion-based (i.e., adding oxidizing agents, such as HNO3 and/or H2O2 to the sample solutions) methods were optimized with the application of chemical modifiers. The mixture of 5 mu g Pd (applied as nitrate) plus 3 mu g Mg(NO3)(2) chemical modifier was proven to be optimal for the present set of analytes and matrix, it allowing the optimal 600 degrees C pyrolysis and 2200 degrees C atomization temperatures, respectively. The IGP of the THGA was pre-heated at 70 degrees C to prevent the sputtering and/or foaming of sample solutions with a high organic content, dispensed together with the modifier solution, which method also improved the reproducibility of the determinations. With the digestion-based method, the recovery ranged between 87 and 122%, while with the direct injection method it was between 96 and 102% for Cd, Cu, and Pb, whereas a lower, compromise recovery of 45-85% was realized for As. The detection limits (LODs) were found to be 5.0, 0.03, 1.2, and 0.8 mu g l(-1) for As, Cd, Cu, and Pb, respectively. The characteristic mass (mo) data were 24 pg As, 1.3 pg Cd, 13 pg Cu, and 35 pg Pb. The upper limits of the linear calibration range were 100, 2, 100, and 200 mu g l(-1) for As, Cd, Cu, and Pb, respectively. The precisions were not worse than 4.8, 3.1, 3.7, and 2.3% for As, Cd, Cu, and Pb, respectively. For arsenic, a higher amount of the modifier (e.g., 20 mu g Pd plus 12 mu g Mg(NO3)(2)) could be recommended to overcome the interference from the presence of sulphate and phosphate in wines. Although this method increased the sensitivity for As (mo = 20 pg), it also enhanced the background noise, thus only a slight improvement in the LOD of As (3.9 mu g l(-1)) was realized. For the 35 red and white wine samples studied, the highest metal contents were observed for Cu ranging from 20 to 640 mu g l(-1) (average: 148 mu g l(-1)), followed by Pb from 6 to 90 mu g l(-1) (average: 32.3 mu g l(-1)), and Cd from 0.05 to 16.5 mu g l(-1) (average: 1.06 mu g l(-1)), whereas the As content was below the LOD. This wide fluctuation in the trace metal content could be associated with the origin of wines from various regions (i.e., different trace metal level and/or quality of soil, and/or anthropogenic impact), and with diverse materials (e.g., additives and containers) involved in the wine production processes. The Cu content of wine samples was significantly correlated with Pb, whereas its weak anti-correlation was found with Cd. Interestingly, the level of Ph was anti-correlated with the year of production of the wines. This is likely due to the gradual decrease in the Ph content of soils of vineyards by time, which certainly causes less Pb-uptake of the grape plant, thus a decrease in the Pb content of wines as well. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:627 / 634
页数:8
相关论文
共 50 条
  • [1] Determination of lead and cadmium in wines by graphite furnace atomic absorption spectrometry
    Kim, M
    FOOD ADDITIVES AND CONTAMINANTS, 2004, 21 (02): : 154 - 157
  • [2] Determination of lead and arsenic in copper aspirinate by graphite furnace atomic absorption spectrometry
    Qiu, HL
    Liu, JS
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2001, 21 (04) : 555 - 557
  • [3] DETERMINATION OF LEAD IN CROATIAN WINES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY
    Tariba, Blanka
    Pizent, Alica
    Kljakovia-Gaspic, Zorana
    ARHIV ZA HIGIJENU RADA I TOKSIKOLOGIJU-ARCHIVES OF INDUSTRIAL HYGIENE AND TOXICOLOGY, 2011, 62 (01): : 25 - 31
  • [4] Determination of arsenic and cadmium in crude oil by direct sampling graphite furnace atomic absorption spectrometry
    de Jesus, Alexandre
    Zmozinski, Ariane Vanessa
    Ferreira Damin, Isabel Cristina
    Silva, Marcia Messias
    Rodrigues Vale, Maria Goreti
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 : 86 - 91
  • [5] Simultaneous Determination of Cadmium and Lead in Medicinal Plants Using Graphite Furnace Atomic Absorption Spectrometry and Direct Slurry Sampling
    Fortunato, Felipe Manfroi
    Gomes Neto, Jose Anchieta
    Giovanni Freschi, Gian Paulo
    ATOMIC SPECTROSCOPY, 2012, 33 (04) : 138 - 142
  • [6] Determination of cadmium, copper and lead in alumina based catalysts by direct solid sampling graphite furnace atomic absorption spectrometry
    Rodrigues, Luiz Frederico
    Paz de Mattos, Julio Cezar
    Dressler, Valderi Luiz
    Pozebon, Dirce
    de Moraes Flores, Erico Marlon
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) : 933 - 938
  • [7] Simultaneous determination of cadmium and lead in cigarettes and cigarette smoke by impaction-graphite furnace and graphite furnace atomic absorption spectrometry
    Smith, MV
    Sneddon, J
    SPECTROSCOPY LETTERS, 1999, 32 (04) : 615 - 621
  • [8] Direct atomic absorption spectrometry determination of arsenic, cadmium, copper, manganese, lead and zinc in vegetable oil and fat samples with graphite filter furnace atomizer
    Zhuravlev, A.
    Zacharia, A.
    Gucer, S.
    Chebotarev, A.
    Arabadji, M.
    Dobrynin, A.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2015, 38 : 62 - 68
  • [10] Determination of arsenic in edible oils by direct graphite furnace atomic absorption spectrometry
    Chen, SS
    Cheng, CC
    Chou, SS
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2003, 11 (03) : 214 - 219