QUANTIFICATION OF REGIONAL LUNG VENTILATION FROM TAGGED HYPERPOLARIZED HELIUM-3 MRI

被引:0
|
作者
Ding, K. [1 ,3 ]
Miller, W. [2 ]
Cao, K. [4 ]
Christensen, G. [4 ]
Reinhardt, J. [3 ]
Benedict, S. [1 ]
Libby, B. [1 ]
Sheng, K. [1 ]
机构
[1] Univ Virginia, Dept Radiat Oncol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Dept Radiol, Charlottesville, VA 22908 USA
[3] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[4] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
来源
2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO | 2011年
关键词
image registration; MR tagging; ventilation; pulmonary; radiation therapy;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper we propose a new scheme for measuring regional ventilation from tagged hyperpolarized helium-3 MR images. A new registration cost function that incorporates both the intensity information (SSD) and the shape feature (SSBMD) from the images is proposed for registering end inspiration to the end expiration image. The smoothness of the displacement field is maintained by incorporating the Laplacian regularization constraint (LAP) in the total cost function. The ventilation is quantified using the Jacobian determinant of the resulting displacement field from the proposed registration algorithm. Tags are automatically segmented from the images to evaluate the registration accuracy. The average tag positioning error is on the order of 2 mm after registration for all three subjects. These results may provide new method for assessing regional lung ventilation and may be used to track regional function changes of lung cancer patients following radiation therapy.
引用
收藏
页码:1074 / 1077
页数:4
相关论文
共 50 条
  • [1] Quantification of regional lung ventilation from tagged hyperpolarized helium-3 MRI
    Department of Radiation Oncology, University of Virginia, Charlottesville 22908, United States
    不详
    不详
    不详
    IEEE Comput. Soc. Conf. Comput. Vis. Pattern Recogn., (1074-1077):
  • [2] Pulmonary Kinematics From Tagged Hyperpolarized Helium-3 MRI
    Tustison, Nicholas J.
    Awate, Suyash P.
    Cai, Jing
    Altes, Talissa A.
    Miller, G. Wilson
    de lange, Eduard E.
    Mugler, John P., III
    Gee, James C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (05) : 1236 - 1241
  • [3] Regional Anisotropy of Airspace Orientation in the Lung as Assessed With Hyperpolarized Helium-3 Diffusion MRI
    Komlosi, Peter
    Altes, Talissa A.
    Qing, Kun
    Mooney, Karen E.
    Miller, G. Wilson
    Mata, Jaime F.
    de lange, Eduard E.
    Tobias, William A.
    Cates, Gordon D., Jr.
    Brookeman, James R.
    Mugler, John P., III
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (06) : 1777 - 1782
  • [4] DYNAMIC MRI OF GRID-TAGGED HYPERPOLARIZED HELIUM-3 FOR THE ASSESSMENT OF LUNG MOTION DURING BREATHING
    Cai, Jing
    Sheng, Ke
    Benedict, Stanley H.
    Read, Paul W.
    Larner, James M.
    Mugler, John P., III
    de Lange, Eduard E.
    Cates, Gordon D., Jr.
    Miller, G. Wilson
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (01): : 276 - 284
  • [5] Regilonal Heterogeneity of Lobar Ventilation in Asthma Using Hyperpolarized Helium-3 MRI
    Zha, Wei
    Kruger, Stanley J.
    Cadman, Robert V.
    Mummy, David G.
    Evans, Michael D.
    Nagle, Scott K.
    Denlinger, Loren C.
    Jarjour, Nizar N.
    Sorkness, Ronald L.
    Fain, Sean B.
    ACADEMIC RADIOLOGY, 2018, 25 (02) : 169 - 178
  • [6] Correlation of Measures of Regional Lung Ventilation from 4DCT vs. Hyperpolarized Helium-3 MR
    Ding, Kai
    Cao, Kunlin
    Miller, Wilson
    Christensen, Gary
    Reinhardt, Joseph
    Benedict, Stanley
    Libby, Bruce
    Sheng, Ke
    MEDICAL IMAGING 2012: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2012, 8317
  • [7] Ventilation Defect Percent from Hyperpolarized Helium-3 MRI Is Predictive of Asthma Exacerbation Severity
    Carey, K.
    Mummy, D.
    Zha, W.
    Evans, M.
    Sorkness, R. L.
    Hall, C.
    Quirk, J. D.
    Yablonskiy, D. A.
    Woods, J. C.
    Denlinger, L. C.
    Jarjour, N. N.
    Castro, M.
    Fain, S. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [8] Regional Comparison Of Vascular Volume Measured On CT With Ventilation Defect Percent On Hyperpolarized Helium-3 Mri In Asthma
    Mummy, D.
    Rahaghi, F. N.
    Zha, W.
    Ross, J.
    Denlinger, L. C.
    Jarjour, N. N.
    Estepar, R. San Jose
    Washko, G.
    Fain, S. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [9] Evaluation of Lung Ventilation and Strain From Direct Measurements of Lung Deformation During Breathing Using Hyperpolarized Helium-3 Tagging MRI
    Cui, T.
    Huang, Q.
    Miller, W. G.
    Zhong, X.
    Yin, F.
    Cai, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S143 - S144
  • [10] Hyperpolarized helium-3 MR imaging of the lung airspaces: Scoring ventilation defects
    Altes, TA
    Cunningham, A
    Conaway, MR
    De Lange, EE
    RADIOLOGY, 2001, 221 : 631 - 631