Amplification volume reduction on DNA database samples using FTA™ Classic Cards

被引:10
|
作者
Wong, Hang Yee [1 ]
Lim, Eng Seng Simon [1 ]
Tan-Siew, Wai Fun [1 ]
机构
[1] Hlth Sci Author, Appl Sci Grp, Div Biol, DNA Database Lab, Singapore 069111, Singapore
关键词
FTA (TM) Classic Card; Volume reduction; DNA; 0.75 mm punches;
D O I
10.1016/j.fsigen.2011.04.008
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
The DNA forensic community always strives towards improvements in aspects such as sensitivity, robustness, and efficacy balanced with cost efficiency. Therefore our laboratory decided to study the feasibility of PCR amplification volume reduction using DNA entrapped in FTA(TM) Classic Card and to bring cost savings to the laboratory. There were a few concerns the laboratory needed to address. First, the kinetics of the amplification reaction could be significantly altered. Second, an increase in sensitivity might affect interpretation due to increased stochastic effects even though they were pristine samples. Third, statics might cause FTA punches to jump out of its allocated well into another thus causing sample-to-sample contamination. Fourth, the size of the punches might be too small for visual inspection. Last, there would be a limit to the extent of volume reduction due to evaporation and the possible need of re-injection of samples for capillary electrophoresis. The laboratory had successfully optimized a reduced amplification volume of 10 mL for FTA samples. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:176 / 179
页数:4
相关论文
共 50 条
  • [1] Use of FTA® classic cards for epigenetic analysis of sperm DNA
    Serra, Olga
    Frazzi, Raffaele
    Perotti, Alessio
    Barusi, Lorenzo
    Buschini, Annamaria
    BIOTECHNIQUES, 2018, 64 (02) : 45 - 51
  • [2] Whatman® FTA® Cards Performance for Ornithobacterium rhinotracheale DNA Amplification
    Veiga, Ines Berenguer
    Muehldorfer, Kristin
    Hafez, Hafez Mohamed
    Lueschow, Doerte
    AVIAN DISEASES, 2020, 64 (04) : 496 - 498
  • [3] Reduction of Powerplex® Y23 Reaction Volume for Genotyping Buccal Cell Samples on FTA™ Cards
    Raziel, Aliza
    Dell'Ariccia-Carmon, Aviva
    Zamir, Ashira
    JOURNAL OF FORENSIC SCIENCES, 2015, 60 (01) : 152 - 156
  • [4] Robust and efficient direct multiplex amplification method for large-scale DNA detection of blood samples on FTA cards
    Jiang Bowei
    Xiang Fawei
    Zhao Xingchun
    Wang Lihua
    Fan Chunhai
    NUCLEAR SCIENCE AND TECHNIQUES, 2013, 24 (03)
  • [5] Robust and efficient direct multiplex amplification method for large-scale DNA detection of blood samples on FTA cards
    JIANG Bowei
    XIANG Fawei
    ZHAO Xingchun
    WANG Lihua
    FAN Chunhai
    Nuclear Science and Techniques, 2013, 24 (03) : 74 - 82
  • [6] DNA elution from buccal cells stored on Whatman FTA Classic Cards using a modified methanol fixation method
    Johanson, Helene C.
    Hyland, Valentine
    Wicking, Carol
    Sturm, Richard A.
    BIOTECHNIQUES, 2009, 46 (04) : 309 - 311
  • [7] Usefulness of FTA® cards as a Pneumocystis-DNA extraction method in bronchoalveolar lavage samples
    Rodino, Jenniffer M.
    Aguilar, Yudy A.
    Vanessa Rueda, Zulma
    Velez, Lazaro A.
    INFECTIOUS DISEASES, 2016, 48 (05) : 367 - 372
  • [8] Optimization of a reduced volume PCR amplification for PowerPlex® Fusion kit using FTA™ cards and generation of population genetic data for Brunei population
    Liew, Paul Vun Onn
    Riccardi, Laura Natalia
    Afolabi, Abimbola Olatunde
    Goodwin, William
    Hadi, Sibte
    ELECTROPHORESIS, 2018, 39 (23) : 2979 - 2990
  • [9] A Suite of Microsatellite Markers Optimized for Amplification of DNA From Addax (Addax nasomaculatus) Blood Preserved on FTA Cards
    Heim, Brett C.
    Ivy, Jamie A.
    Latch, Emily K.
    ZOO BIOLOGY, 2012, 31 (01) : 98 - 106
  • [10] DIRECT PCR AMPLIFICATION OF BLOODSTAINS RECOVERED FROM HARD POROUS MATERIALS USING FTA ELUTE CARDS
    Lipic, Stephen
    Giordullo, Lucille
    Fredericks, Jamie
    FORENSIC SCIENCE INTERNATIONAL, 2017, 277 : 32 - 32