Comparison of Gd-DTPA and Gd-BOPTA for Studying Renal Perfusion and Filtration

被引:15
|
作者
Notohamiprodjo, Mike [1 ]
Pedersen, Michael [2 ]
Glaser, Christian [1 ]
Helck, Andreas D. [1 ]
Lodemann, Klaus-Peter [3 ]
Jespersen, Bente [4 ]
Fischereder, Michael [5 ]
Reiser, Maximilian F. [1 ]
Sourbron, Steven P. [6 ]
机构
[1] Univ Hosp Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Aarhus, Aarhus Univ Hosp, MR Res Ctr, Aarhus, Denmark
[3] Bracco Imaging Germany, Constance, Germany
[4] Univ Aarhus, Aarhus Univ Hosp, Dept Nephrol, Aarhus, Denmark
[5] Univ Hosp Munich, Dept Nephrol, D-81377 Munich, Germany
[6] Univ Leeds, Div Med Phys, Leeds, W Yorkshire, England
关键词
Gd-DTPA; Gd-BOPTA; DCE-MRI; MR-renography; perfusion; CONTRAST-ENHANCED MRI; GLOMERULAR-FILTRATION; GADOBENATE DIMEGLUMINE; IN-VIVO; ANGIOGRAPHY; AGENTS; QUANTIFICATION; RENOGRAPHY; PROTEIN; KIDNEY;
D O I
10.1002/jmri.22640
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To measure the systematic error in perfusion and filtration parameters derived from magnetic resonance (MR) renography caused by protein binding of MR contrast agents. Materials and Methods: Eight healthy Danish Landrace pigs were examined with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). In four pigs a bolus of gadopentetate-dimeglumine (Gd-DTPA; no protein binding) was injected, followed by gadobenate-dimeglumine (Gd-BOPTA; 10% protein binding). The order was reversed in the other four pigs. A two-compartment filtration model was generalized to allow for protein binding and fitted to whole-cortex region of interest (ROI) curves. Single-kidney plasma flow and volume, tubular flow (or GFR), and tubular transit time of both agents were compared. Results: The data show a strong systematic underestimation (P < 0.001) in GFR by Gd-BOPTA (33 +/- 7.2%), and no significant differences (P > 0.05) in plasma flow (2.2 +/- 18%), plasma volume (-1.7 +/- 7.8%) and tubular transit time (3.1 +/- 7.2%). The order of injection had no significant effect. Conclusion: Theory and experiments agree that perfusion parameters of both agents are comparable, whereas GFR is underestimated with Gd-BOPTA due to the dependence of relaxivity on protein content. Hence. GFR cannot be measured with protein-bound contrast agents, but the proposed dual-agent protocol may produce new functional indices measuring protein filtration.
引用
收藏
页码:595 / 607
页数:13
相关论文
共 50 条
  • [1] COMPARISON OF GD-BOPTA WITH GD-DTPA IN MR IMAGING OF RAT-LIVER
    PAVONE, P
    PATRIZIO, G
    BUONI, C
    TETTAMANTI, E
    PASSARIELLO, R
    MUSU, C
    TIRONE, P
    FELDER, E
    RADIOLOGY, 1990, 176 (01) : 61 - 64
  • [2] A comparison of in vivo Gd-NCT trial by using two targeting compounds: Gd-BOPTA and Gd-DTPA
    Zhang, T
    Matsumura, A
    Yamamoto, T
    Yoshida, F
    Sakurai, Y
    Kobayashi, T
    Ono, K
    Nose, T
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 807 - 812
  • [3] Improvement of vascular signal intensity in contrast-enhanced MRA with Gd-BOPTA: Comparison with Gd-DTPA
    Pavone, P
    Catalano, C
    Cademartiri, F
    Luccichenti, G
    Passariello, R
    ACADEMIC RADIOLOGY, 2002, 9 : S134 - S134
  • [4] Liver Perfusion Modifies Gd-DTPA and Gd-BOPTA Hepatocyte Concentrations Through Transfer Clearances Across Sinusoidal Membranes
    Daire, Jean-Luc
    Leporq, Benjamin
    Vilgrain, Valerie
    Van Beers, Bernard E.
    Schmidt, Sabine
    Pastor, Catherine M.
    EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 2017, 42 (04) : 657 - 667
  • [5] Liver Perfusion Modifies Gd-DTPA and Gd-BOPTA Hepatocyte Concentrations Through Transfer Clearances Across Sinusoidal Membranes
    Jean-Luc Daire
    Benjamin Leporq
    Valérie Vilgrain
    Bernard E. Van Beers
    Sabine Schmidt
    Catherine M. Pastor
    European Journal of Drug Metabolism and Pharmacokinetics, 2017, 42 : 657 - 667
  • [6] Gd-BOPTA enhanced MRA vs Gd-DTPA enhanced MRA in the assessment of carotid artery stenosis
    Catalano, C
    Pavone, P
    Laghi, A
    Napoli, A
    Pediconi, F
    Passariello, R
    RADIOLOGY, 1999, 213P : 142 - 142
  • [7] Comparison of gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for enhanced MR imaging of brain and spine tumours in children
    Colosimo, C
    Demaerel, P
    Tortori-Donati, P
    Christophe, C
    Van Buchem, M
    Högström, B
    Pirovano, G
    Shen, N
    Kirchin, M
    Spinazzi, A
    PEDIATRIC RADIOLOGY, 2005, 35 (05) : 501 - 510
  • [8] Intraindividueller Vergleich dreier Kontrastmittel (Gd-DTPA, Gd-BOPTA und Gd-BT-DO3A) mit der multiphasischen MR-AngiographieMultiphasic MR angiography as an intra-individual comparison between the contrast agents Gd-DTPA, Gd-BOPTA, and Gd-BT-DO3A
    H. von Tengg-Kobligk
    F. Floemer
    M.V. Knopp
    Der Radiologe, 2003, 43 (2): : 171 - 178
  • [9] Comparison of gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for enhanced MR imaging of brain and spine tumours in children
    Cesare Colosimo
    Philippe Demaerel
    Paolo Tortori-Donati
    Catherine Christophe
    Mark Van Buchem
    Barry Högström
    Gianpaolo Pirovano
    Ningyan Shen
    Miles A. Kirchin
    Alberto Spinazzi
    Pediatric Radiology, 2005, 35 : 501 - 510
  • [10] A comparison of two MR hepatobiliary gadolinium chelates: Gd-BOPTA and Gd-EOB-DTPA
    Runge, VM
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (04) : 643 - 650