Accuracy of a PDA-based dietary assessment program

被引:82
|
作者
Beasley, J [1 ]
Riley, WT [1 ]
Jean-Mary, J [1 ]
机构
[1] PICS Inc, Reston, VA USA
关键词
nutritional assessment; diet record; personal digital assistant computer;
D O I
10.1016/j.nut.2004.11.006
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: Study objectives were to assess the accuracy of a food record delivered on a personal digital assistant (PDA) and to examine sources of error from the PDA-based food record. Methods: Thirty-nine adults recruited with a newspaper advertisement were trained to record food intake using DietMatePro, a dietary assessment program delivered on a PDA. After 3 d of use, subjects returned for a follow-up visit in which a 24-h recall was conducted. Subjects also were timed while recording an observed, weighed lunch. Recalled and actual food intakes were compared with estimates recorded by the subjects when using the PDA. Paired sample t tests and Pearson's correlations assessed means and measurements of association between DietmatePro data compared with the 24-h recall data and observed meal data. Bland-Altman plots were used to assess bias in food recording. Sources of error were quantified by using calories as the unit for comparison. Results: There were no significant differences in daily totals for calories and macronutrients between DietMatePro data and comparison measurements. Pearson's correlations of associations between DietMatePro data and the comparison measurement ranged from 0.505 to 0.797 (P < 0.005, n = 28) for the 24-h recall and from 0.419 to 0.786 (P < 0.005, n = 33) for the observed lunch, depending on the nutrient measured. The largest source of absolute error in caloric estimation was attributable to portion size estimation error (49%). Conclusions: DietMatePro, a PDA-based dietary. assessment program, provides a method of assessing energy and macronutrient intakes comparable to the 24-h recall in samples lacking dietary restrictions. © 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:672 / 677
页数:6
相关论文
共 50 条
  • [1] Evaluation of a PDA-based dietary assessment and intervention program: A randomized controlled trial
    Beasley, Jeannette M.
    Riley, William T.
    Davis, Amanda
    Singh, Jatinder
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2008, 27 (02) : 280 - 286
  • [2] Evaluation of a PDA-based dietary assessment and intervention program: A randomized controlled trial.
    Beasley, J. M.
    Riley, W. T.
    Singh, J.
    Davis, A.
    Behar, A.
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 2006, 163 (11) : S38 - S38
  • [3] A PDA-based sign translator
    Zhang, J
    Chen, XL
    Yang, J
    Waibel, A
    [J]. FOURTH IEEE INTERNATIONAL CONFERENCE ON MULTIMODAL INTERFACES, PROCEEDINGS, 2002, : 217 - 222
  • [4] A Home-Care PDA-Based Program for the Management of COPD Patients
    Teijeiro, Tomas
    Tarasco, Miguel
    Felix, Paulo
    Maria Presedo, Jesus
    [J]. MEDICAL INFORMATICS IN A UNITED AND HEALTHY EUROPE, 2009, 150 : 439 - 439
  • [5] A preliminary study of PDA-based dietary self-monitoring in hemodialysis patients
    Sevick, MA
    Piraino, B
    Sereika, S
    Starrett, T
    Bender, C
    Bernardini, J
    Stark, S
    Burke, LE
    [J]. JOURNAL OF RENAL NUTRITION, 2005, 15 (03) : 304 - 311
  • [6] Digital phonocardiography: A PDA-based approach
    Brusco, M
    Nazeran, H
    [J]. PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2299 - 2302
  • [7] A PDA-based face recognition system
    Yang, J
    Chen, XL
    Kunz, W
    [J]. SIXTH IEEE WORKSHOP ON APPLICATIONS OF COMPUTER VISION, PROCEEDINGS, 2002, : 19 - 23
  • [8] Design of a PDA-based telerobotic system
    Lin, Zijing
    Meng, Max Q. -H.
    Chen, Wanming
    Liang, Huawei
    Liu, Xin
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-5, 2007, : 1563 - 1567
  • [9] A mobile PDA-based wireless pulse oxitnieter
    Mendelson, Yitzhak
    Floroff, Vladimir
    Johnston, William
    Branche, Paul
    [J]. Proceedings of the IASTED International Conference on TELEHEALTH, 2005, : 1 - 6
  • [10] Modification of a PDA-based system for data collection
    Hsieh, Y
    Brennan, PF
    [J]. AMIA 2002 SYMPOSIUM, PROCEEDINGS: BIOMEDICAL INFORMATICS: ONE DISCIPLINE, 2002, : 1048 - 1048