Characterization of detector scintillator effect on interventional device visualization in X-ray fluoroscopy

被引:0
|
作者
Jiang, YH [1 ]
Wilson, DL [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
关键词
scintillator; flat-panel detectors; guidewire; stent; x-ray fluoroscopy;
D O I
10.1117/12.595951
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Hat panel detectors have a large number of parameters that affect fluoroscopy image quality. Scintillator thickness is very important and can be changed in fabrication. In general, with increasing thickness, there is a degradation of MTF with spatial blurring but improved conversion efficiency. This design trade-off should be optimized for visualization. Using quantitative experimental and techniques, we simulated three detector models, including a direct detector and two indirect detectors with different scintillator thickness (160 and 210 mg/cm(2)) and displayed each "acquired" pixel directly on the screen without further processing in a sequence of fluoroscopy images. To measure image quality, we investigated detection of two interventional devices: stents and guide wires. Human observers and a channelized human observer model both demonstrated that detection depended on detector scintillator thickness and the type of interventional device. Detection performance was improved with the thicker scintillator, especially at low exposure. A simulated direct detector gave less blurring and even better detection performance for stent detection. The thick indirect detector gave contrast sensitivities equal to those for the direct detector for the case of guide wire detection. An ideal observer model gave trends similar to those for human observers, even though it does not account for many features of human viewing of image sequences and gives extraordinarily high detection SNR values because it uses all images in a sequence.
引用
收藏
页码:328 / 337
页数:10
相关论文
共 50 条
  • [1] Characterization of detector scintillator effect on interventional device visualization in x-ray fluoroscopy
    Jiang, Yuhao
    Wilson, David L.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1850 - 1853
  • [2] Optimization of detector pixel size for interventional x-ray fluoroscopy
    Manjeshwar, RM
    Wilson, DL
    MEDICAL IMAGING 2001: IMAGE PERCEPTION AND PERFORMANCE, 2001, 4324 : 23 - 34
  • [3] Optimization of detector pixel size for stent visualization in x-ray fluoroscopy
    Jiang, YH
    Wilson, DL
    MEDICAL PHYSICS, 2006, 33 (03) : 668 - 678
  • [4] Optimization of detector pixel size for stent visualization in x-ray fluoroscopy
    Jiang, Y
    Wilson, DL
    MEDICAL IMAGING 2004: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2004, 5372 : 311 - 318
  • [5] Experimental optimization of detector pixel size for stent visualization in x-ray fluoroscopy
    Jiang, YH
    Wilson, DL
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 552 - 555
  • [6] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY
    LABBE, MS
    CHIU, MY
    RZESZOTARSKI, MS
    BANIHASHEMI, AR
    WILSON, DL
    MEDICAL PHYSICS, 1994, 21 (03) : 471 - 481
  • [7] 6 MVp x-ray imaging with a transparent scintillator x-ray detector
    Zeman, HD
    Samant, SS
    Rasmussen, J
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 388 - 394
  • [8] Optimal flat-panel detector pixel size for visualization of stents in x-ray fluoroscopy
    Jiang, YH
    Srinivas, Y
    Wilson, DL
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1037 - 1038
  • [9] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY - RESPONSE
    WILSON, D
    RZESZOTARSKI, MS
    MEDICAL PHYSICS, 1994, 21 (12) : 1887 - 1887
  • [10] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY - COMMENT
    WALMSLEY, JJ
    MEDICAL PHYSICS, 1994, 21 (12) : 1885 - 1885