Effective use of balloon guide catheters in reducing incidence of mechanical thrombectomy related distal embolization

被引:44
|
作者
Lee, Dong Hoon [1 ]
Sung, Jae Hoon [1 ]
Kim, Sang Uk [1 ]
Yi, Ho Jun [1 ]
Hong, Jae Taek [1 ]
Lee, Sang Won [1 ]
机构
[1] Catholic Univ Korea, St Vincents Hosp, Dept Neurosurg, 93 Jungbu Daero Paldal Gu, Suwon 16247, South Korea
关键词
Mechanical thrombectomy; Distal embolization; Balloon-guided catheter; ACUTE ISCHEMIC-STROKE; ENDOVASCULAR TREATMENT; FLOW REVERSAL; DEVICE; OCCLUSION; EXPERIENCE; ASPIRATION; EXTRACTION; THERAPY; MODEL;
D O I
10.1007/s00701-017-3256-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The clinical benefit of endovascular stroke therapy has been demonstrated in several prospective randomized trials. However, in a relevant percentage of patients, mechanical thrombectomy bears the risk of causing new infarction in initially unaffected vascular territories through thrombus fragmentation and migration of clot debris. The goal of this study was to evaluate the use of the balloon guide catheter (BGC) to effectively achieve flow arrest and thrombus aspiration during the intervention to avoid distal embolization. A retrospective study was performed in 139 patients between October 2010 and May 2016 to analyze occlusions in the middle cerebral artery (MCA) or internal carotid artery (ICA) by using a stent retriever with a BGC (n = 73) or a non-BGC (n = 66). The following data were collected: patient age and gender, along with history of diabetes mellitus, hypertension, atrial fibrillation, smoking, obesity, dyslipidemia, and previous ischemic stroke. Data on procedure time, number of passes, and angiographic findings were also collected. The final reperfusion score was rated based on the Thrombolysis in Cerebral Infarction (TICI) grading scale. Successful recanalization was defined as TICI 3 or 2b. A total of 139 patients underwent mechanical thrombectomy with the stent retriever. Of the 139 patients, 73 (52.5%) underwent placement of a BGC. The mean age was 65.8 +/- 13.5 years, and the median National Institutes of Health Stroke Scale (NIHSS) score was 11. The average initial NIHSS score was lower in the BGC group compared with the non-BGC group (mean, 11.2 +/- 5.6 vs. 13.2 +/- 5.6; P = 0.03). Patients with BGC had fewer incidences of previous ischemic stroke (12.3% vs. 28.8%; P = 0.01). The numbers of passes were similar between the two groups. The procedure time (99 +/- 49.4 min vs. 124 +/- 72.2 min; P = 0.02) and the time from onset of symptoms to procedure end (302 +/- 102 min vs. 357.2 +/- 136.1 min; P = 0.009) were shorter in the BGC group. TICI 3 or 2b recanalization scores were higher in the BGC group compared to the non-BGC group [63/73, 86.3% vs. 48/66, 72.7%; odds ratio (OR), 0.6; 95% confidence interval (CI), 0.2-1.4; P = 0.04]. Importantly, distal embolization was less frequent in the BGC group (5/73, 6.8% vs. 21/66, 31.8%; OR, 6.3; 95% CI, 2.2-18.0; P < 0.001). The risk of distal embolization was significantly decreased with the use of a BGC.
引用
收藏
页码:1671 / 1677
页数:7
相关论文
共 50 条
  • [1] Effective use of balloon guide catheters in reducing incidence of mechanical thrombectomy related distal embolization
    Dong Hoon Lee
    Jae Hoon Sung
    Sang Uk Kim
    Ho Jun Yi
    Jae Taek Hong
    Sang Won Lee
    Acta Neurochirurgica, 2017, 159 : 1671 - 1677
  • [2] Balloon-Guide Catheters Are Needed for Effective Flow Reversal during Mechanical Thrombectomy
    Nikoubashman, O.
    Wischer, D.
    Hennemann, H. M.
    Sandmann, J.
    Sichtermann, T.
    Mueschenich, F. S.
    Reich, A.
    Wiesmann, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (11) : 2077 - 2081
  • [3] DISTAL EMBOLIZATION DURING MECHANICAL THROMBOLYSIS - ROTATIONAL THROMBECTOMY VS BALLOON ANGIOPLASTY
    TITUS, BG
    AUTH, DC
    RITCHIE, JL
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 19 (04): : 279 - 285
  • [4] Comparison of Balloon Guide Catheter versus Non-Balloon Guide Catheter for Mechanical Thrombectomy in Distal Medium Vessel Occlusion
    Orscelik, Atakan
    Kallmes, David F.
    Bilgin, Cem
    Senol, Yigit Can
    Kobeissi, Hassan
    Elawady, Sameh Samir
    Cunningham, Conor
    Spiotta, Alejandro M.
    STROKE, 2024, 55
  • [5] Comparison of balloon guide catheter versus non-balloon guide catheter for mechanical thrombectomy in patients with distal medium vessel occlusion
    Orscelik, Atakan
    Kallmes, David F.
    Bilgin, Cem
    Musmar, Basel
    Senol, Yigit Can
    Kobeissi, Hassan
    Elawady, Sameh Samir
    Cunningham, Conor
    Matsukawa, Hidetoshi
    Zandpazandi, Sara
    Sowlat, Mohammad-Mahdi
    Maier, Ilko
    Al Kasab, Sami
    Jabbour, Pascal
    Kim, Joon-tae
    Wolfe, Stacey Q.
    Rai, Ansaar
    Starke, Robert M.
    Psychogios, Marios-Nikos
    Samaniego, Edgar A.
    Arthur, Adam S.
    Yoshimura, Shinichi
    Cuellar, Hugo
    Howard, Brian M.
    Alawieh, Ali
    Romano, Daniele G.
    Tanweer, Omar
    Mascitelli, Justin
    Fragata, Isabel
    Polifka, Adam J.
    Osbun, Joshua W.
    Crosa, Roberto Javier
    Matouk, Charles
    Park, Min S.
    Levitt, Michael R.
    Moss, Mark
    Dumont, Travis M.
    Williamson, Richard
    Navia, Pedro
    Kan, Peter
    De Leacy, Reade
    Chowdhry, Shakeel A.
    Ezzeldin, Mohamad
    Spiotta, Alejandro M.
    Brinjikji, Waleed
    STAR Collaborators
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024, 16 (06) : 587 - 594
  • [6] Impact of Balloon Guide Catheters in Elderly Patients Treated with Mechanical Thrombectomy: Insights from the ROSSETTI Registry
    Terceno, Mikel
    Bashir, Saima
    Puig, Josep
    Daunis-I-Estadella, Josep
    Murias, Eduardo
    Jimenez, Jose Maria
    Diaz, Eva Gonzalez
    Monso, Jon Fondevila
    Bravo-Rey, Isabel
    Romero, Veredas
    Werner, Mariano
    Lopez-Rueda, Antonio
    Roman, Luis San
    Anadaluz, Jordi Blasco
    Doncel-Moriano, Antonio
    Rosati, Santiago
    Perez-Garcia, Carlos
    Remollo, Sebastian
    Caamano, Isabel Rodriguez
    Aixut, Sonia
    Chaparro, Oscar Sabino Chirife
    Garcia, Juan Manuel Sanchis
    Porto-Alvarez, Jacobo
    Mendez-Cendon, Jose Carlos
    Rayon-Aledo, Jose Carlos
    Aguilar, Yeray
    Parrilla, Guillermo
    Castano, Miguel
    Serena, Joaquin
    Silva, Yolanda
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (11) : 1275 - 1281
  • [7] Comparison of a Balloon Guide Catheter and a Non-Balloon Guide Catheter for Mechanical Thrombectomy
    Velasco, Aglae
    Buerke, Boris
    Stracke, Christian P.
    Berkemeyer, Shoma
    Mosimann, Pascal J.
    Schwindt, Wolfram
    Alcazar, Pedro
    Cnyrim, Christian
    Niederstadt, Thomas
    Chapot, Rene
    Heindel, Walter
    RADIOLOGY, 2016, 280 (01) : 169 - 176
  • [8] Balloon guide catheters: use, reject, or randomize?
    Goyal, Mayank
    Kappelhof, Manon
    Ospel, Johanna M.
    Bala, Fouzi
    NEURORADIOLOGY, 2021, 63 (08) : 1179 - 1183
  • [9] Balloon guide catheters: use, reject, or randomize?
    Mayank Goyal
    Manon Kappelhof
    Johanna M. Ospel
    Fouzi Bala
    Neuroradiology, 2021, 63 : 1179 - 1183
  • [10] The Effects of Balloon-Guide Catheters on Outcomes after Mechanical Thrombectomy in Acute Ischemic Strokes : A Meta-Analysis
    Ahn, Jun Hyong
    Cho, Steve S.
    Kim, Sung-Eun
    Kim, Heung Cheot
    Jeon, Jin Pyeong
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2019, 62 (04) : 389 - 397