The effect of micro-motion on the tissue response around immediately loaded roughened titanium implants in the rabbit

被引:72
|
作者
Vandamme, Katleen
Naert, Ignace
Geris, Liesbet
Sloten, Jozef Vander
Puers, Robert
Duyck, Joke
机构
[1] Catholic Univ Louvain, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, BIOMAT Res Grp,Dept Prosthet Dent, B-3000 Louvain, Belgium
[2] Catholic Univ Louvain, Div Biomech & Engn Design, B-3000 Louvain, Belgium
[3] Catholic Univ Louvain, ESAT, MICAS, Dept Elect Engn, B-3000 Louvain, Belgium
关键词
animal; bone chamber; bone formation; immediate loading; implant roughness;
D O I
10.1111/j.1600-0722.2007.00416.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Initial osteogenesis at the implant interface is, to a great extent, determined by the implant surface characteristics and the interfacial loading conditions. The present study investigated the effect of various degrees of relative movement on the tissue differentiation around a roughened screw-shaped immediately loaded implant. Repeated-sampling bone chambers were installed in the tibia of 10 rabbits. In each of the chambers, three experiments were performed by inducing 0 (control), 30, and 90 mu m implant displacement for 9 wk. A linear mixed model and a logistic mixed model with alpha = 5% determined statistical significance. Tissue filling of the bone chamber was similar for the three test conditions. The bone area fraction was significantly higher for 90 mu m implant displacement compared with no displacement. A significantly higher fraction of bone trabeculae was found for 30 and 90 mu m implant displacement compared with the unloaded situation. The incidence of osteoid-to-implant and bone-to-implant contact was significantly higher for 90 mu m implant displacement compared with 30 and 0 mu m implant displacement. Significantly more osteoid in contact with the implant was found for the loaded conditions compared with no loading. Well-controlled micro-motion positively influenced bone formation at the interface of a roughened implant. An improved bone reaction was detected with increasing micro-motion.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 35 条
  • [1] The effect of micro-motion on the tissue response around immediately loaded roughened titanium implants in the rabbit (vol 115, pg 21, 2007)
    Vandamme, K.
    Naert, I
    Geris, L.
    Vander Sloten, J.
    Puers, R.
    Duyck, J.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2007, 115 (02) : 167 - 167
  • [2] The influence of micro-motion on the tissue differentiation around immediately loaded cylindrical turned titanium implants
    Duyck, J
    Vandamme, K
    Geris, L
    Van Oosterwyck, H
    De Cooman, M
    Vandersloten, J
    Puers, R
    Naert, I
    ARCHIVES OF ORAL BIOLOGY, 2006, 51 (01) : 1 - 9
  • [3] Histodynamics of bone tissue formation around immediately loaded cylindrical implants in the rabbit
    Vandamme, Katleen
    Naert, Ignace
    Geris, Liesbet
    Vander Sloten, Jozef
    Puers, Robert
    Duyck, Joke
    CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (04) : 471 - 480
  • [4] The Biologic Width Around Titanium Implants: Histometric Analysis of the Implantogingival Junction Around Immediately and Early Loaded Implants
    Bakaeen, Lara
    Quinlan, Paul
    Schoolfied, John
    Lang, Niklaus P.
    Cochran, David L.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2009, 29 (03) : 297 - 306
  • [5] Stability and Bone Response of Immediately Loaded Micro-implants in Beagle Dogs
    Ma, Junqing
    Zhang, Weibing
    Wang, Lin
    Zhao, Chunyang
    Chen, Wenjing
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (05) : 885 - 890
  • [6] Early cortical bone healing around loaded titanium implants: a histological study in the rabbit
    Slaets, Elke
    Naert, Ignace
    Carmeliet, Geert
    Duyck, Joke
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (02) : 126 - 134
  • [7] Numerical simulation of tissue differentiation around loaded titanium implants in a bone chamber
    Geris, L
    Andreykiv, A
    Van Oosterwyck, H
    Vander Sloten, J
    van Keulen, F
    Duyck, J
    Naert, I
    JOURNAL OF BIOMECHANICS, 2004, 37 (05) : 763 - 769
  • [8] Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures
    Akça, K
    Akkocaoglu, M
    Cömert, A
    Tekdemir, I
    Çehreli, MC
    CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (06) : 715 - 722
  • [9] THE TISSUE-RESPONSE TO LOADED HA COATED AND GRIT TITANIUM IMPLANTS IN DOGS
    BLOCK, MS
    KENT, JN
    FINGER, IM
    MOHR, G
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1988, 46 (12) : M23 - M23
  • [10] Collagen fiber orientation in human peri-implant bone around immediately loaded and unloaded titanium dental implants
    Traini, T
    Degidi, M
    Caputi, S
    Strocchi, R
    Di Iorio, D
    Piattelli, A
    JOURNAL OF PERIODONTOLOGY, 2005, 76 (01) : 83 - 89