Reactive power allocation through the modified Z-bus and Aumann-Shapley method

被引:2
|
作者
Castille C, Carlos [1 ]
Molina, Yuri [2 ]
Luyo, Jaime [1 ]
Pegado, Raoni [2 ]
机构
[1] Natl Univ Engn, Fac Mech Engn, Lima, Peru
[2] Univ Fed Paraiba, Dept Elect Engn, Joao Pessoa, Paraiba, Brazil
关键词
Reactive power allocation; Circuit laws; Aumann-Shapley method; Modified Z-bus;
D O I
10.1016/j.epsr.2020.106966
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new method based on the circuit theory and game theory for the allocation of reactive power. The allocation is calculated for each load, identifying and quantifying the responsibility of each reactive source. In the proposed method: the generators, line shunt, and bus shunt are modeled as current sources and loads are modeled as constant admittance, and obtained modified Z-bus matrix using circuit theory, which was coupled to the Aumann-Shapley method for calculating the unitary participation of each current source in the reactive power consumed by each load, considering each one as an independent player of the "reactive power allocation" game. The properties of the Aumann-Shapley method ensure equitable allocation and recovery of the total reactive power. Numerical results applied to the 5-bus and IEEE 30-bus systems are presented, discussed and compared with the other methods to demonstrate the applicability of the proposed method.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Reactive power service cost allocation using Aumann-Shapley method
    Lin, X. J.
    Yu, C. W.
    Xu, N.
    Chung, C. Y.
    Wu, H.
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2006, 153 (05) : 540 - 546
  • [2] Transmission loss allocation through modified Z-bus
    Parastar, A.
    Mozafari, B.
    Pirayesh, A.
    Omidi, H.
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) : 752 - 756
  • [3] DLMP calculation based on power loss and emission reduction allocation using Aumann-Shapley method
    Chen X.
    Yu Q.
    Xie J.
    Yu K.
    Gan L.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (04): : 17 - 23
  • [4] Improved Z-Bus loss allocation method through redistribution
    Zhao, N
    Song, YH
    Bie, ZH
    Takahashi, S
    Sekine, Y
    UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings, 2005, : 1101 - 1105
  • [5] Loss Allocation in Distribution Networks Based on Aumann-Shapley
    Amaris, Hortensia
    Molina, Yuri P.
    Alonso, Monica
    Luyo, Jaime E.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (06) : 6655 - 6666
  • [6] Congestion cost allocation method based on Aumann-Shapley value in bilateral model
    Yang, HM
    Shi, DY
    Duan, XZ
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1002 - 1006
  • [7] AN APPLICATION OF THE AUMANN-SHAPLEY PRICES FOR COST ALLOCATION IN TRANSPORTATION PROBLEMS
    SAMET, D
    TAUMAN, Y
    ZANG, I
    MATHEMATICS OF OPERATIONS RESEARCH, 1984, 9 (01) : 25 - 42
  • [8] Transmission Network Cost Allocation Based on Circuit Theory and the Aumann-Shapley Method
    Molina, Yuri P.
    Saavedra, Osvaldo R.
    Amaris, Hortensia
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (04) : 4568 - 4577
  • [9] Z-bus loss allocation
    Conejo, AJ
    Galiana, FD
    Kockar, I
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2001, 16 (01) : 105 - 110
  • [10] Transmission cost allocation based on the modified Z-bus
    Nikoukar, J.
    Haghifam, M. R.
    Parastar, A.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 31 - 37