Simultaneous Analysis of Iodine and Bromine Species in Infant Formula using HPLC-ICP-MS

被引:5
|
作者
Nelson, Jenny [1 ]
Pacquette, Lawrence [2 ]
Dong, Shuofei [1 ]
Yamanaka, Michiko [1 ]
机构
[1] Agilent Technol, 5301 Stevens Creek Blvd, Santa Clara, CA 95051 USA
[2] Abbott Nutr, 3300 Stelzer Rd, Columbus, OH 43219 USA
关键词
THYROID-HORMONE; METABOLISM; SPECIATION;
D O I
10.5740/jaoacint.18-0352
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: A fast and sensitive method for the simultaneous analysis of iodine and bromine species in infant formula was developed using HPLC-inductively coupled plasma-MS (HPLC-ICP-MS). Method: To determine the four halogen species [iodide (I-), iodate (IO3-), bromide (Br-), and bromate (BrO3-)] in a milk-based Standard Reference Material and four commercially available infant formula products. Results: The four halogen species were baseline separated in less than 6.5 min using an anion exchange resin column and 5.0 mM NaH2PO4 / 15.0 mM Na2SO4 / 5.0 mM EDTA (pH 7.0) mobile phase. Following separation, the halogen species were detected by measuring m/z 79 for Br and m/z 127 for I using a triple quadrupole-ICP-MS. The instrument was operated in single quadrupole mode with helium cell gas. Excellent linearity (R = 0.9999 or better) was obtained for all four species with calibration standards ranging from 0 to 100 ppb. The LOD for I-, IO3-, Br-, and BrO3- were all less than 0.67 mu g/kg. To test the suitability of the method for the accurate determination of low concentrations of the four species in infant formula samples, a spike recovery test was carried out at 20 and 40 mu g/kg into the diluted infant formula samples. Conclusions: Total elemental determinations of iodine and bromine were also performed using the triple quadrupole-ICP-MS without HPLC.
引用
收藏
页码:1199 / 1204
页数:6
相关论文
共 50 条
  • [1] The analysis of antimony species by using ESI-MS and HPLC-ICP-MS
    J. Lintschinger
    O. Schramel
    A. Kettrup
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 96 - 102
  • [2] The analysis of antimony species by using ESI-MS and HPLC-ICP-MS
    Lintschinger, J
    Schramel, O
    Kettrup, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (02): : 96 - 102
  • [3] A new method for the analysis of arsenic species in urine by using HPLC-ICP-MS
    Lintschinger, J
    Schramel, P
    Hatalak-Rauscher, A
    Wendler, I
    Michalke, B
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (03): : 313 - 318
  • [4] A new method for the analysis of arsenic species in urine by using HPLC-ICP-MS
    J. Lintschinger
    P. Schramel
    A. Hatalak-Rauscher
    I. Wendler
    B. Michalke
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 313 - 318
  • [5] Simultaneous determination of oxo- and thio-arsenic species using HPLC-ICP-MS
    Kana, Antonin
    Sadowska, Martyna
    Kvicala, Jaroslav
    Mestek, Oto
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2020, 92
  • [6] Analysis of Arsenic Species in Processed Rice Bran Products Using HPLC-ICP-MS
    Kim, So Young
    Seo, Dongwon
    Yoo, Miyoung
    Lee, Kwang-Geun
    JOURNAL OF FOOD SCIENCE, 2018, 83 (10) : 2682 - 2687
  • [7] Analysis of arsenic species formed in the human gastrointestinal matrix using HPLC-ICP-MS
    Alava, P.
    Du Laing, G.
    Van de Wiele, T.
    Tack, F.
    ARSENIC IN GEOSPHERE AND HUMAN DISEASES, 2010, : 492 - 493
  • [8] Use of the bromine isotope ratio in HPLC-ICP-MS and HPLC-ESI-MS analysis of a new drug in development
    Cuyckens, Filip
    Balcaen, Lieve I. L.
    De Wolf, Kenny
    De Samber, Bjorn
    Van Looveren, Cis
    Hurkmans, Rob
    Vanhaecke, Frank
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (07) : 1717 - 1729
  • [9] Use of the bromine isotope ratio in HPLC-ICP-MS and HPLC-ESI-MS analysis of a new drug in development
    Filip Cuyckens
    Lieve I. L. Balcaen
    Kenny De Wolf
    Bjorn De Samber
    Cis Van Looveren
    Rob Hurkmans
    Frank Vanhaecke
    Analytical and Bioanalytical Chemistry, 2008, 390 : 1717 - 1729
  • [10] Determination of arsenic species in rice grains using HPLC-ICP-MS
    Ji-Young Kim
    Won-Il Kim
    Anitha Kunhikrishnan
    Dae-Won Kang
    Doo-Ho Kim
    Young-Ja Lee
    Young-Jun Kim
    Cheong-Tae Kim
    Food Science and Biotechnology, 2013, 22 : 1509 - 1513