No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis

被引:127
|
作者
Shammas, H. John
Shammas, Maya C.
机构
[1] Univ So Calif, Dept Ophthalmol, Keck Sch Med, Los Angeles, CA 90089 USA
[2] Cornell Univ, Joan & Sanford I Weill Med Coll, New York, NY USA
来源
关键词
D O I
10.1016/j.jcrs.2006.08.045
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To prospectively evaluate the no-history method for intraocular lens (IOL) power calculation in 15 cataractous eyes that had previous myopic laser in situ keratomileusis (LASIK) and for which the pre-LASIK K-readings were not available. SETTING: Private practice, Lynwood, California, USA. METHODS: The predicted IOL power was calculated in each case. Also calculated were the mean arithmetic and absolute IOL predictor errors, range of the prediction errors, and number of eyes in which the error was within +/- 1.00 diopter (D). RESULTS: The mean arithmetic IOL prediction error was -0.003 D +/- 0.63 (SD), and the mean absolute IOL prediction error was 0.55 +/- 0.31 D (range -0.89 to + 1.05 D). Fourteen eyes (93.3%) were within +/- 1.00 D. The results of the Shammas post-LASIK formula compared favorably to the results obtained with the optimized Holladay 1 (P =.42), Hoffer Q (P =.25), Haigis (P =.30), and Holladay 2 (P =.19) formulas and were better than the results obtained with the optimized SRK/T formula (P =.0005). CONCLUSION: The no-history method is a viable alternative for IOL power calculation after myopic LASIK when the refractive surgery data are not available.
引用
下载
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [1] Diffractive intraocular lens power after myopic laser in situ keratomileusis
    Savini, Giacomo
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05): : 796 - 797
  • [2] Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis
    Helaly, Hany A.
    El-Hifnawy, Mohammad A. M.
    Shaheen, Mohamed Shafik
    Abou El-Kheir, Amr F.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (01) : 122 - 128
  • [3] Accurate intraocular lens power calculation after myopic laser in situ keratomileusis, bypassing corneal power
    Walter, KA
    Gagnon, MR
    Hoopes, PC
    Dickinson, PJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03): : 425 - 429
  • [4] Intraocular lens power calculation after myopic laser in situ keratomileusis: Estimating the corneal refractive power
    Awwad, Shady T.
    Manasseh, Christian
    Bowman, R. Wayne
    Cavanagh, H. Dwight
    Verity, Steven
    Mootha, Vinod
    McCulley, James P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (07): : 1070 - 1076
  • [5] Corneal asphericity and intraocular lens power after myopic laser in situ keratomileusis
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Ducoli, Pietro
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10): : 1543 - 1543
  • [6] Diffractive intraocular lens power after myopic laser in situ keratomileusis REPLY
    Alfonso, Jose F.
    Madrid-Costa, David
    Poo-Lopez, Arancha
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05): : 797 - 797
  • [7] Corneal asphericity and intraocular lens power after myopic laser in situ keratomileusis Reply
    Mori, Yosai
    Shimizu, Kimiya
    Minami, Keiichiro
    Kamiya, Kazutaka
    Shoji, Nobuyuki
    Miyata, Kazunori
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10): : 1544 - 1544
  • [8] Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis
    Gimbel, HV
    Sun, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04): : 571 - 576
  • [10] Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis
    Shammas, HJ
    Shammas, MC
    Garabet, A
    Kim, JH
    Shammas, A
    LaBree, L