Analytical-scale microwave-assisted extraction

被引:39
|
作者
Eskilsson, CS [1 ]
Björklund, E [1 ]
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
reviews; microwave-assisted extraction; extraction methods; pharmaceutical analysis; pesticides; phenols; metals; polymers; polynuclear aromatic hydrocarbons; polychlorinated biphenyls;
D O I
10.1016/S0021-9673(00)00921-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microwave-assisted extraction (MAE) is a process of using microwave energy to heat solvents in contact with a sample in order to partition analytes from the sample matrix into the solvent. The ability to rapidly heat the sample solvent mixture is inherent to MAE and the main advantage of this technique. By using closed vessels the extraction can be performed at elevated temperatures accelerating the mass transfer of target compounds from the sample matrix. A typical extraction procedure takes 15-30 min and uses small solvent volumes in the range of 10-30 mi. These volumes are about 10 times smaller than volumes used by conventional extraction techniques. In addition, sample throughput is increased as several samples can be extracted simultaneously. In most cases recoveries of analytes and reproducibility are improved compared to conventional techniques, as shown in several applications. This review gives a brief theoretical background of microwave heating and the basic principles of using microwave energy for extraction. It also attempts to summarize all studies performed on closed-vessel MAE until now. The influences of parameters such as solvent choice, solvent volume, temperature, time and matrix characteristics (including water content) are discussed. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:227 / 250
页数:24
相关论文
共 50 条
  • [1] ANALYTICAL-SCALE SUPERCRITICAL FLUID EXTRACTION
    HAWTHORNE, SB
    ANALYTICAL CHEMISTRY, 1990, 62 (11) : A633 - &
  • [2] Collection in analytical-scale supercritical fluid extraction
    Turner, C
    Eskilsson, CS
    Björklund, E
    JOURNAL OF CHROMATOGRAPHY A, 2002, 947 (01) : 1 - 22
  • [3] Microwave-Assisted Industrial Scale Cannabis Extraction
    Radoiu, Marilena
    Kaur, Harmandeep
    Bakowska-Barczak, Anna
    Splinter, Steven
    TECHNOLOGIES, 2020, 8 (03)
  • [4] MICROWAVE-ASSISTED EXTRACTION
    RENOE, BW
    AMERICAN LABORATORY, 1994, 26 (12) : 34 - 40
  • [5] Microwave-assisted extraction
    Destandau, Emilie
    Michel, Thomas
    Elfakir, Claire
    RSC Green Chemistry, 2013, : 113 - 156
  • [6] Dynamic microwave-assisted extraction
    Ericsson, M
    Colmsjö, A
    JOURNAL OF CHROMATOGRAPHY A, 2000, 877 (1-2) : 141 - 151
  • [7] ANALYTICAL-SCALE EXTRACTION OF ENVIRONMENTAL-SAMPLES USING SUPERCRITICAL FLUIDS
    HAWTHORNE, SB
    MILLER, DJ
    LANGENFELD, JJ
    BURFORD, MD
    ACS SYMPOSIUM SERIES, 1992, 508 : 206 - 221
  • [8] Microwave-Assisted Extraction of Flavonoids: A Review
    Routray, Winny
    Orsat, Valerie
    FOOD AND BIOPROCESS TECHNOLOGY, 2012, 5 (02) : 409 - 424
  • [9] MAP™:: Microwave-assisted extraction of cockroaches
    Yaylayan, VA
    Paré, JRJ
    Matni, G
    Bélanger, JMR
    NATURAL PRODUCT LETTERS, 2002, 16 (02): : 123 - 127
  • [10] Microwave-assisted extraction of felodipine tablets
    Eskilsson, CS
    Björklund, E
    Mathiasson, L
    Karlsson, L
    Torstensson, A
    JOURNAL OF CHROMATOGRAPHY A, 1999, 840 (01) : 59 - 70