Constant linear velocity spiral scanning for near video rate 4D OCT ophthalmic and surgical imaging with isotropic transverse sampling

被引:46
|
作者
Carrasco-Zevallos, Oscar M. [1 ]
Viehland, Christian [1 ]
Keller, Brenton [1 ]
McNabb, Ryan P. [2 ]
Kuo, Anthony N. [1 ,2 ]
Izatt, Joseph A. [1 ,2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Med Ctr, Dept Ophthalmol, Durham, NC 27710 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2018年 / 9卷 / 10期
基金
美国国家卫生研究院;
关键词
OPTICAL COHERENCE TOMOGRAPHY; HAND-HELD; MOTION CORRECTION; ANTERIOR SEGMENT; SPEED; ANGIOGRAPHY;
D O I
10.1364/BOE.9.005052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ultrahigh speed optical coherence tomography (OCT) systems with >100 kHz A-scan rates can generate volumes rapidly with minimal motion artifacts and are well suited for 4D imaging (volumes through time) applications such as intra-operative imaging. In such systems, high OCT data acquisition efficiency (defined as the fraction of usable A-scans generated during the total acquisition time) is desired to maximize the volumetric frame rate and sampling pitch. However, current methods for beam scanning using non-resonant and resonant mirror scanners can result in severe scan distortion and transverse oversampling as well as require acquisition dead times, which limit the acquisition efficiency and performance of ultrahigh speed 4D OCT. We introduce constant linear velocity spiral scanning (CLV-SC) as a novel beam scanning method to maximize the data acquisition efficiency of ultrahigh speed 4D OCT systems. We demonstrate that CLV-SC does not require acquisition dead times and achieves more uniform transverse sampling compared to raster scanning. To assess its clinical utility, we implement CLV-SC with a 400 kHz OCT system and image the anterior eye and retina of healthy adults at up to 10 volumes per second with isotropic transverse sampling, allowing B-scans with equal sampling pitch to be extracted from arbitrary locations within a single volume. The feasibility of CLV-SC for infra-operative imaging is also demonstrated using a 800 kHz OCT system to image simulated retinal surgery at 15 volumes per second with isotropic transverse sampling, resulting in high quality volume renders that enable clear visualization of surgical instruments and manipulation of tissue. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:5052 / 5070
页数:19
相关论文
共 4 条
  • [1] Automated instrument-tracking for 4D video-rate imaging of ophthalmic surgical maneuvers
    Tang, Eric M.
    El-Haddad, Mohamed T.
    Patel, Shriji N.
    Tao, Yuankai K.
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (03): : 1471 - 1484
  • [2] Microscope-integrated OCT at 800 kHz line rate for high speed 4D imaging of ophthalmic surgery
    Carrasco-Zevallos, Oscar
    Viehland, Christian
    Keller, Brenton
    Kuo, Anthony N.
    Toth, Cynthia A.
    Izatt, Joseph A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [3] Deep-learning based automated instrument tracking and adaptive-sampling of intraoperative OCT for video-rate volumetric imaging of ophthalmic surgical maneuvers
    El-Haddad, Mohamed T.
    Malone, Joseph D.
    Hoang, Nancy T.
    Tao, Yuankai K.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXIII, 2019, 10867
  • [4] Deep-learning based automated instrument-tracking and adaptive-sampling for 4D imaging of ophthalmic surgical maneuvers
    Tang, Eric
    El-Haddad, Mohamed T.
    Malone, Joseph D.
    Tao, Yuankai
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)