Per-organ assessment of subject-induced susceptibility distortion for MR-only male pelvis treatment planning

被引:12
|
作者
Glide-Hurst, Carri [1 ]
Nejad-Davarani, Siamak [1 ]
Weiss, Steffen [2 ]
Zheng, Weili [3 ]
Chetty, Indrin J. [1 ]
Renisch, Steffen [2 ]
机构
[1] Henry Ford Canc Inst, Dept Radiat Oncol, Detroit, MI 48202 USA
[2] Philips Res Labs, Dept Digital Imaging, D-22335 Hamburg, Germany
[3] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
来源
RADIATION ONCOLOGY | 2018年 / 13卷
基金
美国国家卫生研究院;
关键词
CONFORMAL RADIATION-THERAPY; PROSTATE-CANCER; GEOMETRIC DISTORTION; BRAIN IMAGES; REGISTRATION; OPTIMIZATION; RADIOTHERAPY; SIMULATION; SCANNER; PHANTOM;
D O I
10.1186/s13014-018-1090-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Patient-specific distortions, particularly near tissue/air interfaces, require assessment for magnetic resonance (MR) only radiation treatment planning (RTP). However, patients are dynamic due to changes in physiological status during imaging sessions. This work investigated changes in subject-induced susceptibility distortions to pelvic organs at different bladder states to support pelvis MR-only RTP. Methods: Pelvises of 9 healthy male volunteers were imaged at 1.0 Tesla (T),1.5 T, and 3.0 T. Subject-induced susceptibility distortion field maps were generated using a dual-echo gradient-recalled echo (GRE) sequence with B-0 field maps obtained from the phase difference between the two echoes acquired at several bladder volume states (3-4/subject, 32 overall). T2 turbo spin echo images were also acquired at each bladder state for organ delineation. Magnet central frequency was tracked over time. Distortion map differences and boxplots were computed to characterize changes within the clinical target volume (CTV), bladder, seminal vesicles, and prostate volumes. Results: The time between the initial and final BO maps was 42.6 +/- 13.9 (range: 13.2-62.1) minutes with minimal change in magnet central frequency (0.02 +/- 0.05 mm (range: - 0.06 - 0.12 mm)). Subject-induced susceptibility distortion across all bladder states, field strengths, and subjects was relatively small (1.4-1.9% of all voxels in the prostate and seminal vesicles were distorted > 0.5 mm). In the bladder, no voxels exhibited distortions > 1 mm. An extreme case acquired at 3.0 T with a large volume of rectal air yielded 27.4-34.6% of voxels within the CTVs had susceptibility-induced distortions > 0.5 mm across all time points. Conclusions: Our work suggests that subject-induced susceptibility distortions caused by bladder/rectal conditions are generally small and subject-dependent Local changes may be non-negligible within the CTV, thus proper management of filling status is warranted. Future work evaluating the impact of multiple models to accommodate for extreme status changes may be advantageous.
引用
收藏
页数:9
相关论文
共 9 条
  • [1] Per-organ assessment of subject-induced susceptibility distortion for MR-only male pelvis treatment planning
    Carri Glide-Hurst
    Siamak Nejad-Davarani
    Steffen Weiss
    Weili Zheng
    Indrin J. Chetty
    Steffen Renisch
    Radiation Oncology, 13
  • [2] FMEA of MR-Only Treatment Planning in the Pelvis
    Kim, Joshua
    Miller, Brett
    Siddiqui, M. Salim
    Movsas, Benjamin
    Glide-Hurst, Carri
    ADVANCES IN RADIATION ONCOLOGY, 2019, 4 (01) : 168 - 176
  • [3] On the Need for a Dynamic Model for Patient-Specific Distortion Corrections for MR-Only Pelvis Treatment Planning
    Glide-Hurst, C.
    Zheng, W.
    Stehning, C.
    Weiss, S.
    Renisch, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3661 - 3661
  • [4] To evaluate the feasibility of MR-only pelvis TomoTherapy during treatment planning and verification
    Man, S. Y.
    Appleyard, R.
    Chiu, G.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S1054 - S1054
  • [5] Optimization of a Novel Large Field of View Distortion Phantom for MR-Only Treatment Planning
    Price, R. G.
    Knight, R. A.
    Hwang, K.
    Bayram, E.
    Glide-Hurst, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3734 - 3734
  • [6] Optimization of a novel large field of view distortion phantom for MR-only treatment planning
    Price, Ryan G.
    Knight, Robert A.
    Hwang, Ken-Pin
    Bayram, Ersin
    Nejad-Davarani, Siamak P.
    Glide-Hurst, Carri K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04): : 51 - 61
  • [7] A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck
    Maspero, M.
    Seevinck, P. R.
    Meijer, G. J.
    Lagendijk, J. J. W.
    Viergever, M. A.
    van den Berg, C. A. T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3316 - 3316
  • [8] Validation of a Commercial Continuous Hounsfield Unit (HU) Pelvis Synthetic CT Platform for MR-Only Prostate Radiotherapy Treatment Planning
    Yu, V.
    Hunt, M.
    Cervino, L.
    Damato, A.
    Tyagi, N.
    MEDICAL PHYSICS, 2020, 47 (06) : E669 - E669
  • [9] Dosimetry Validation of MR-Only Treatment Planning Based upon the Synthetic MRCAT Pelvis with Continuous Hounsfield Units in Prostate Cancer
    Benayun, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E643 - E644