Measurement of fine particles in diesel emissions using a real-time aerosol monitor

被引:6
|
作者
Zhu, JP [1 ]
Aikawa, B
Pigeon, R
机构
[1] Hlth Canada, Safe Environm, Div Chem Res, Ottawa, ON K1A 0L2, Canada
[2] Nat Resources Canada, CANMET Energy Technol Ctr, Ottawa, ON, Canada
关键词
D O I
10.1080/10473289.2005.10464701
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A real-time monitoring methodology to determine diesel fine particles in diesel emissions has been evaluated. The range of particle size captured by the monitor was similar to 0.1 mu m to 1 mu m. DustTrak real-time monitors were connected to the dilution tunnel of the vehicle exhaust to measure the emissions during the vehicle tests under both dynamic and steady-state driving conditions, and concentration data were recorded every 5 sec. Test variation of the real-time monitoring among different test days was similar to that measured by traditional filter-based gravimetric method, whereas the repeatability of the monitor data within the same-day tests was better than that of gravimetric method. Correlations between the two methods were established for different fuels tested on a single light duty vehicle. When the emissions from the reference fuel was used to convert the monitor's response to diesel fuels, the levels determined by the real-time monitor were consistent with those measured by gravimetric method among different fuels tested. Use of the real-time monitor could provide information on the levels of fine particles that is more relevant to the public health than the total particles.
引用
收藏
页码:978 / 983
页数:6
相关论文
共 50 条
  • [1] Real-time measurement of the aerodynamic size of individual aerosol particles
    Xia, ZH
    Li, F
    Zheng, HY
    Rui, H
    Zhang, YY
    Kong, XH
    Gu, XJ
    Yuan, Z
    Zhang, WJ
    Jian, B
    Xiong, LY
    [J]. ACTA PHYSICA SINICA, 2004, 53 (01) : 320 - 324
  • [2] Real-time measurement of chemical compositions of individual aerosol particles
    Xia, ZH
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (07) : 973 - 976
  • [3] REAL-TIME MEASUREMENT OF THE ABSORPTION-COEFFICIENT OF AEROSOL-PARTICLES
    HANSEN, ADA
    ROSEN, H
    NOVAKOV, T
    [J]. APPLIED OPTICS, 1982, 21 (17): : 3060 - 3062
  • [4] Real-time measurement of diesel exhaust
    Erickson, BE
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (09) : 155A - 155A
  • [5] Real-Time Measurement of NOx Emissions from Modern Diesel Vehicles Using On-Board Sensors
    Selleri, Tommaso
    Ferrarese, Christian
    Franzetti, Jacopo
    Suarez-Bertoa, Ricardo
    Manara, Dario
    [J]. ENERGIES, 2022, 15 (22)
  • [6] Real-time diesel particulate monitor for underground mines
    Noll, James
    Janisko, Samuel
    Mischler, Steven E.
    [J]. ANALYTICAL METHODS, 2013, 5 (12) : 2954 - 2963
  • [7] A PIEZOELECTRIC AEROSOL MASS MONITOR FOR REAL-TIME MEASUREMENTS
    SEM, GJ
    QUANT, FR
    [J]. STAUB REINHALTUNG DER LUFT, 1982, 42 (06): : 258 - 258
  • [8] Evaluation of the pDR-1200 real-time aerosol monitor
    Benton-Vitz, Kaila
    Volckens, John
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2008, 5 (06) : 353 - 359
  • [9] Real-time measurement of correlated size and composition profiles of individual atmospheric aerosol particles
    Noble, CA
    Prather, KA
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (09) : 2667 - 2680
  • [10] Real-time measurement of sodium in single aerosol particles by flame emission: laboratory characterization
    Clark, CD
    Campuzano-Jost, P
    Covert, DS
    Richter, RC
    Maring, H
    Hynes, AJ
    Saltzman, ES
    [J]. JOURNAL OF AEROSOL SCIENCE, 2001, 32 (06) : 765 - 778